Analytical considerations in deriving 99th percentile upper reference limits for high-sensitivity cardiac troponin assays: Educational recommendations from the IFCC committee on clinical application of cardiac bio-markers
The International Federation of Clinical Chemistry Committee on Clinical Application of Cardiac Bio-Markers provides evidence-based educational documents to facilitate uniform interpretation and utilization of cardiac biomarkers in clinical laboratories and practice. The committee’s goals are to improve the understanding of certain key analytical and clinical aspects of cardiac biomarkers and how these may interplay in clinical practice. Measurement of high-sensitivity cardiac troponin (hs-cTn) assays is a cornerstone in the clinical evaluation of patients with symptoms and/or signs of acute cardiac ischemia. To define myocardial infarction, the Universal Definition of Myocardial Infarction requires patients who manifest with features suggestive of acute myocardial ischemia to have at least one cTn concentration above the sex-specific 99th percentile upper reference limit (URL) for hs-cTn assays and a dynamic pattern of cTn concentrations to fulfill the diagnostic criteria for MI. This special report provides an overview of how hs-cTn 99th percentile URLs should be established, including recommendations about prescreening and the number of individuals required in the reference cohort, how statistical analysis should be conducted, optimal preanalytical and analytical protocols, and analytical/biological interferences or confounds that can affect accurate determination of the 99th percentile URLs. This document also provides guidance and solutions to many of the issues posed.publishedVersio
Recommended from our members
Multicenter assessment of a hemoglobin A1c point-of-care device for diagnosis of diabetes mellitus.
ObjectiveA multisite investigation compared the analytical performance of a point-of-care (POC) HbA1c device with multiple commonly used HbA1c laboratory methods and an NGSP (National Glycohemoglobin Standardization Program) reference method.Research design and methodsThe Afinion AS100 POC device analyzed HbA1c using 618 EDTA whole blood excess patient specimens with clinically indicated HbA1c testing. Results were compared to measurements across five clinical laboratories and the NGSP reference method. Precision was evaluated over 8-10 consecutive days for low-, mid-, and high-range HbA1c specimens at all five sites.ResultsOver a wide range of HbA1c values (4.0%-15% HbA1c), 97.1% of the POC results and 94.5% of routine laboratory results fell within the target value of ±6% of the NGSP reference method results. The POC HbA1c results at 6.5% exhibited a total relative bias of -0.6% (-0.04% HbA1c) compared to the reference method while the aggregate of laboratory methods displayed a relative bias of -0.9% (-0.06% HbA1c). The total imprecision of the POC results ranged from 0.74-2.13% CV across the analytic measurement range compared to 0.81-3.23% CV for the routine laboratory methods.ConclusionsThe accuracy and precision of the Afinion POC HbA1c method was comparable to the laboratory HbA1c methods supporting the FDA's recent approval of the Afinion HbA1c Dx device for use in the diagnosis of diabetes
Antibody-mediated interferences affecting cardiac troponin assays:recommendations from the IFCC Committee on Clinical Applications of Cardiac Biomarkers
The International Federation of Clinical Chemistry Committee on Clinical Applications of Cardiac Biomarkers (IFCC C-CB) provides educational documents to facilitate the interpretation and use of cardiac biomarkers in clinical laboratories and practice. Our aim is to improve the understanding of certain key analytical and clinical aspects of cardiac biomarkers and how these may interplay. Measurements of cardiac troponin (cTn) have a prominent place in the clinical work-up of patients with suspected acute coronary syndrome. It is therefore important that clinical laboratories know how to recognize and assess analytical issues. Two emerging analytical issues resulting in falsely high cTn concentrations, often several fold higher than the upper reference limit (URL), are antibody-mediated assay interference due to long-lived cTn-antibody complexes, called macrotroponin, and crosslinking antibodies that are frequently referred to as heterophilic antibodies. We provide an overview of antibody-mediated cTn assay interference and provide recommendations on how to confirm the interference and interpret the results
Cardiac Biomarkers and the Diagnosis of Myocardial Infarction in Women
PURPOSE OF REVIEW: Women with suspected acute coronary syndrome are less likely to undergo investigation or receive treatment than men, and women consistently have poorer outcomes. This review summarises how the latest development in cardiac biomarkers could improve both diagnosis and outcomes in women. RECENT FINDINGS: Novel high-sensitivity cardiac troponin assays have identified differences in the reference range and therefore diagnostic threshold for myocardial infarction in men and women. These differences are present across multiple populations with different ethnic backgrounds and for a range of assays. The use of a uniform threshold for cardiac troponin does not provide equivalent prediction in men and women, with lower thresholds needed for women to provide comparable risk stratification. SUMMARY: Sex differences in cardiac troponin concentrations are not widely recognised in clinical practice and may be contributing to the under-diagnosis of myocardial infarction in women and discrepancies in patient care and outcomes
31st Annual Meeting and Associated Programs of the Society for Immunotherapy of Cancer (SITC 2016) : part two
Background
The immunological escape of tumors represents one of the main ob- stacles to the treatment of malignancies. The blockade of PD-1 or CTLA-4 receptors represented a milestone in the history of immunotherapy. However, immune checkpoint inhibitors seem to be effective in specific cohorts of patients. It has been proposed that their efficacy relies on the presence of an immunological response. Thus, we hypothesized that disruption of the PD-L1/PD-1 axis would synergize with our oncolytic vaccine platform PeptiCRAd.
Methods
We used murine B16OVA in vivo tumor models and flow cytometry analysis to investigate the immunological background.
Results
First, we found that high-burden B16OVA tumors were refractory to combination immunotherapy. However, with a more aggressive schedule, tumors with a lower burden were more susceptible to the combination of PeptiCRAd and PD-L1 blockade. The therapy signifi- cantly increased the median survival of mice (Fig. 7). Interestingly, the reduced growth of contralaterally injected B16F10 cells sug- gested the presence of a long lasting immunological memory also against non-targeted antigens. Concerning the functional state of tumor infiltrating lymphocytes (TILs), we found that all the immune therapies would enhance the percentage of activated (PD-1pos TIM- 3neg) T lymphocytes and reduce the amount of exhausted (PD-1pos TIM-3pos) cells compared to placebo. As expected, we found that PeptiCRAd monotherapy could increase the number of antigen spe- cific CD8+ T cells compared to other treatments. However, only the combination with PD-L1 blockade could significantly increase the ra- tio between activated and exhausted pentamer positive cells (p= 0.0058), suggesting that by disrupting the PD-1/PD-L1 axis we could decrease the amount of dysfunctional antigen specific T cells. We ob- served that the anatomical location deeply influenced the state of CD4+ and CD8+ T lymphocytes. In fact, TIM-3 expression was in- creased by 2 fold on TILs compared to splenic and lymphoid T cells. In the CD8+ compartment, the expression of PD-1 on the surface seemed to be restricted to the tumor micro-environment, while CD4 + T cells had a high expression of PD-1 also in lymphoid organs. Interestingly, we found that the levels of PD-1 were significantly higher on CD8+ T cells than on CD4+ T cells into the tumor micro- environment (p < 0.0001).
Conclusions
In conclusion, we demonstrated that the efficacy of immune check- point inhibitors might be strongly enhanced by their combination with cancer vaccines. PeptiCRAd was able to increase the number of antigen-specific T cells and PD-L1 blockade prevented their exhaus- tion, resulting in long-lasting immunological memory and increased median survival
The use of biomarkers for the evaluation and treatment of patients with acute coronary syndromes
The advent of inexpensive, highly accurate, and predictive markers of myocardial injury, inflammation, and hemodynamic stability has revolutionized the evaluation and treatment of patients who have acute coronary syndromes (ACSs). These blood biomarkers require small sample volumes, can be run expeditiously, and provide important information concerning the diagnosis, risk stratification, and treatment of these patients. To understand the use of these markers, one must have some knowledge about what elevations in these markers imply, how they have to be collected and measured to provide reliable information, when to suspect analytic confounds, and what the key values are that impart the diagnostic, prognostic, and therapeutic information. This article discusses these issues, emphasizing what clinicians must know for optimal test use, and then addresses the practical use of these markers in patients who have ACS
The use of biomarkers for the evaluation and treatment of patients with acute coronary syndromes
The advent of inexpensive, highly accurate, and predictive markers of myocardial injury, inflammation, and hemodynamic stability has revolutionized the evaluation and treatment of patients who have acute coronary syndromes (ACSs). These blood biomarkers require small sample volumes, can be run expeditiously, and provide important information concerning the diagnosis, risk stratification, and treatment of these patients. To understand the use of these markers, one must have some knowledge about what elevations in these markers imply, how they have to be collected and measured to provide reliable information, when to suspect analytic confounds, and what the key values are that impart the diagnostic, prognostic, and therapeutic information. This article discusses these issues, emphasizing what clinicians must know for optimal test use, and then addresses the practical use of these markers in patients who have ACS
Circulating Ionized Magnesium: Comparisons with Circulating Total Magnesium and the Response to Magnesium Supplementation in a Randomized Controlled Trial
Ionized Mg (iMg) is considered the biologically active fraction of circulating total Mg (tMg). It is possible that iMg may be a more physiologically relevant marker than tMg. Using data from a double-blind pilot randomized controlled trial, we tested (1) whether oral Mg supplementation will increase iMg concentrations compared with placebo and (2) the relationship between iMg and tMg at baseline. Additionally, we evaluated the agreement between iMg measured in fresh whole blood versus stored samples. A total of fifty-nine participants were randomized 1:1 to oral Mg supplementation (400 mg/day, Mg Oxide) or placebo for 10 weeks. Fasting blood samples were obtained at baseline and follow-up. The analysis used linear regression and an intent-to-treat approach. Participants were generally healthy, the mean age was 62, and 73% were female. The baseline iMg and tMg were modestly and positively associated (r = 0.50). The ratio of baseline iMg to tMg was 64%. The mean supplement effect on iMg was 0.03 mmol/L (95% CI:0.01, 0.05) for Mg supplementation versus placebo. The supplement effect on iMg was not statistically significantly different according to baseline iMg status (above/below median). Compared to fresh blood, iMg was consistently higher in refrigerated and frozen samples by 0.14 and 0.20 mmol/L, respectively. In this relatively healthy adult population, Mg supplementation over 10 weeks resulted in increased iMg concentrations. Whether iMg is a more appropriate measure of Mg status than tMg, and the public health or clinical utility of measuring iMg remains to be determined