35 research outputs found

    Electron beam driven alkali metal atom source for loading a magneto-optical trap in a cryogenic environment

    Full text link
    We present a versatile and compact electron beam driven source for alkali metal atoms, which can be implemented in cryostats. With a heat load of less than 10mW, the heat dissipation normalized to the atoms loaded into the magneto-optical Trap (MOT), is about a factor 1000 smaller than for a typical alkali metal dispenser. The measured linear scaling of the MOT loading rate with electron current observed in the experiments, indicates that electron stimulated desorption is the corresponding mechanism to release the atoms.Comment: 5 pages, 3 figure

    Translating Research on Myoelectric Control into Clinics-Are the Performance Assessment Methods Adequate?

    Get PDF
    Missing an upper limb dramatically impairs daily-life activities. Significant efforts in overcoming the issues arising from this disability have been made in both academia and industry, although their clinical outcome is still limited. Translation of prosthetic research into clinics has been challenging because of the difficulties in meeting the necessary requirements of the market. In this perspective, we focus on myocontrol algorithms for upper limb prostheses and we emphasize that one relevant factor determining the relatively small clinical impact of these methods is the limit of commonly used laboratory performance metrics. The laboratory conditions, in which the majority of the solutions are being evaluated, fail to sufficiently replicate real-life challenges. We qualitatively substantiate this argument with data from seven transradial amputees. Their ability to control a myoelectric prosthesis was tested by measuring the accuracy of offline EMG signal classification, as a typical laboratory performance metrics, as well as by clinical scores when performing standard tests of daily living. Despite all subjects reached relatively high classification accuracy offline, their clinical scores were largely different and were not strongly predicted by classification accuracy. As argued in previous reports, we reinforce the suggestion to test myocontrol systems using clinical tests on amputees, fully fitted with sockets and prostheses highly resembling the systems they would use in daily living, as evaluation benchmark. Agreement on this level of testing for systems developed in research laboratories would facilitate clinically relevant progresses in this field.<br

    Elective amputation and bionic substitution restore functional hand use after critical soft tissue injuries

    Get PDF
    Critical soft tissue injuries may lead to a non-functional and insensate limb. In these cases standard reconstructive techniques will not suffice to provide a useful outcome, and solutions outside the biological arena must be considered and offered to these patients. We propose a concept which, after all reconstructive options have been exhausted, involves an elective amputation along with a bionic substitution, implementing an actuated prosthetic hand via a structured tech-neuro-rehabilitation program. Here, three patients are presented in whom this concept has been successfully applied after mutilating hand injuries. Clinical tests conducted before, during and after the procedure, evaluating both functional and psychometric parameters, document the benefits of this approach. Additionally, in one of the patients, we show the possibility of implementing a highly functional and natural control of an advanced prosthesis providing both proportional and simultaneous movements of the wrist and hand for completing tasks of daily living with substantially less compensatory movements compared to the traditional systems. It is concluded that the proposed procedure is a viable solution for re-gaining highly functional hand use following critical soft tissue injuries when existing surgical measures fail. Our results are clinically applicable and can be extended to institutions with similar resources

    Ultra-Low-Power Digital Filtering for Insulated EMG Sensing

    No full text
    Myoelectric prostheses help amputees to regain independence and a higher quality of life. These prostheses are controlled by state-of-the-art electromyography sensors, which use a conductive connection to the skin and are therefore sensitive to sweat. They are applied with some pressure to ensure a conductive connection, which may result in pressure marks and can be problematic for patients with circulatory disorders, who constitute a major group of amputees. Here, we present ultra-low-power digital signal processing algorithms for an insulated EMG sensor which couples the EMG signal capacitively. These sensors require neither conductive connection to the skin nor electrolytic paste or skin preparation. Capacitive sensors allow straightforward application. However, they make a sophisticated signal amplification and noise suppression necessary. A low-cost sensor has been developed for real-time myoelectric prostheses control. The major hurdles in measuring the EMG are movement artifacts and external noise. We designed various digital filters to attenuate this noise. Optimal system setup and filter parameters for the trade-off between attenuation of this noise and sufficient EMG signal power for high signal quality were investigated. Additionally, an algorithm for movement artifact suppression, enabling robust application in real-world environments, is presented. The algorithms, which require minimal calculation resources and memory, are implemented on an ultra-low-power microcontroller.(VLID)344808

    An Insulated Flexible Sensor for Stable Electromyography Detection : Application to Prosthesis Control

    No full text
    Electromyography (EMG), the measurement of electrical muscle activity, is used in a variety of applications, including myoelectric upper-limb prostheses, which help amputees to regain independence and a higher quality of life. The state-of-the-art sensors in prostheses have a conductive connection to the skin and are therefore sensitive to sweat and require preparation of the skin. They are applied with some pressure to ensure a conductive connection, which may result in pressure marks and can be problematic for patients with circulatory disorders, who constitute a major group of amputees. Due to their insulating layer between skin and sensor area, capacitive sensors are insensitive to the skin condition, they require neither conductive connection to the skin nor electrolytic paste or skin preparation. Here, we describe a highly stable, low-power capacitive EMG measurement set-up that is suitable for real-world application. Various flexible multi-layer sensor set-ups made of copper and insulating foils, flex print and textiles were compared. These flexible sensor set-ups adapt to the anatomy of the human forearm, therefore they provide high wearing comfort and ensure stability against motion artifacts. The influence of the materials used in the sensor set-up on the magnitude of the coupled signal was demonstrated based on both theoretical analysis and measurement.The amplifier circuit was optimized for high signal quality, low power consumption and mobile application. Different shielding and guarding concepts were compared, leading to high SNR.(VLID)344807

    A myokinetic hmi for the control of hand prostheses: A feasibility study

    No full text
    In an attempt to overcome the several limitations of currently available/investigated human-machine interfaces (HMI) for the control of robotic hand prostheses, we propose a new HMI exploiting the magnetic field produced by magnets implanted in the muscles. As a magnet is implanted in a muscle it will travel with it, and its localization could provide a direct measure of the contraction/elongation of that muscle, which is voluntarily controlled by the individual. Here we present a proof of concept of a single magnet localizer, which computes on-line the position of a magnet in a certain workspace. In particular, the system comprises a pair of magnetic field sensors mounted on custom printed circuit boards, and an algorithm that resolves the inverse magnetic problem using the magnetic dipole model. The accuracy and the repeatability of our system were evaluated using six miniature magnets. Ongoing results suggest that the envisioned system is viable

    Wilcoxon signed-rank test results of the tta for each option between the two methods.

    No full text
    <p>Wilcoxon signed-rank test results of the tta for each option between the two methods.</p

    GA performance results for the different object’s position.

    No full text
    <p>1 grasp attempt was the minimum possible value for this measurement. The error bars indicate the standard error.</p
    corecore