1,023 research outputs found

    Effects of Vagus Nerve Stimulation on Sleep-related Breathing in Epilepsy Patients

    Full text link
    Purpose: To describe the effects of vagus nerve stimulation (VNS) on sleep-related breathing in a sample of 16 epilepsy patients. Methods: Sixteen adults with medically refractory epilepsy (nine men, seven women, ages 21–58 years) underwent baseline polysomnograms (PSGs). Three months after VNS therapy was initiated, PSGs were repeated. In addition, patient 7 had a study with esophageal pressure monitoring, and patient 1 had a continuous positive airway pressure (CPAP) trial. Results: Baseline PSGs: One of 16 patients had an apnea–hypopnea index (AHI) >5 (6.8). Treatment PSGs: Five of 16 patients had treatment AHIs >5. Respiratory events were more frequent during periods with VNS activation (on-time) than without VNS activation (off-time; p = 0.016 ). Follow-up studies: Esophageal pressure monitoring in patient 7 showed crescendos in esophageal pressure during VNS activation, supporting an obstructive pattern. The CPAP trial of patient 1 showed that all respiratory events were associated with VNS stimulation at low CPAP levels. They were resolved at higher CPAP levels. Conclusions: Treatment with VNS affects respiration during sleep and should be used with care, particularly in patients with preexisting obstructive sleep apnea. The AHI after VNS treatment remained <5 in the majority of patients and was only mildly elevated (<12) in five patients. In one patient, CPAP resolved VNS-related respiratory events.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/66447/1/j.1528-1157.2003.56202.x.pd

    Efficacy and patient satisfaction with autoadjusting CPAP with variable expiratory pressure vs standard CPAP: a two-night randomized crossover trial

    Get PDF
    Expiratory pressure relief (C-Flex) technology monitors the patient’s airflow during expiration and reduces the pressure in response to the patient. Increased comfort levels associated with C-Flex therapy have potential to improve patient adherence to therapy. The purpose of this study was to assess the combination of autoadjusting CPAP (APAP) and C-Flex in terms of (1) treatment efficacy, and (2) patient preference when compared to standard CPAP. Fifteen patients who had previously undergone formal CPAP titration polysomnography were treated with either one night of the APAP with C-Flex or one night of conventional CPAP, in a crossover trial. Patient satisfaction levels were recorded using visual analog scales (VAS) on the morning after the study. Mean patient age was 50 ± 12 years, body mass index (BMI) was 36 ± 6 kg/m(2), baseline AHI was 53 ± 31 events/h, and CPAP Pressure was 11 ± 2 cm/H(2)O. APAP with C-Flex was as effective as CPAP, with no differences detected in sleep latency (17 ± 5 vs 12.3 ± 3 min, p = 0.4), or respiratory indices (AHI of 4.2 ± 2 vs 2.4 ± 0.7 events/h, p = 0.1). VAS scores (scale 0–10) indicated a trend towards increased patient satisfaction while using APAP with C-Flex (7.9 vs 7.2, p = 0.07). 10 patients expressed a preference for APAP with C-Flex (VAS, 0 to10) over standard CPAP (total positive score of 68, mean score of 4.8 ± 4.3). One patient expressed no preference. Four patients expressed a preference for CPAP (total positive score of 13, mean score of 0.9 ± 1.9) (APAP with C-Flex vs standard CPAP, p < 0.01 paired t test). APAP with C-Flex eliminates sleep disordered breathing as effectively as standard CPAP. Patients indicated a preference for APAP with C-Flex suggesting a possible advantage in terms of patient adherence for this mode of treatment

    How are normal sleeping controls selected? A systematic review of cross-sectional insomnia studies, and a standardised method to select healthy controls for sleep research

    Get PDF
    There appears to be some inconsistency in how normal sleepers (controls) are selected and screened for participation in research studies for comparison with insomnia patients. The purpose of the current study is to assess and compare methods of identifying normal sleepers in insomnia studies, with reference to published standards. We systematically reviewed the literature on insomnia patients which included control subjects. The resulting 37 articles were systematically reviewed with reference to the five criteria for normal sleep specified by Edinger et al. (2004). In summary, these criteria are: evidence of sleep disruption; sleep scheduling; general health; substance/medication use; and other sleep disorders. We found sleep diaries, PSG, and clinical screening examinations to be widely used with both control subjects and insomnia participants. However, there are differences between research groups in the precise definitions applied to the components of normal sleep. We found that none of reviewed studies applied all of the Edinger et al. criteria, and 16% met four criteria. In general, screening is applied most rigorously at the level of a clinical disorder, whether physical, psychiatric, or sleep. While the Edinger et al. criteria seem to be applied in some form by most researchers, there is scope to improve standards and definitions in this area. Ideally, different methods such as sleep diaries and questionnaires would be used concurrently with objective measures to ensure normal sleepers are identified, and descriptive information for control subjects would be reported. Here, we have devised working criteria and methods to be used for assessment of normal sleepers. This would help clarify the nature of the control group, in contrast to insomnia subjects and other patient groups

    Sleep characteristics of persons with chronic fatigue syndrome and non-fatigued controls: results from a population-based study

    Get PDF
    BACKGROUND: The etiology and pathophysiology of chronic fatigue syndrome (CFS) remain inchoate. Attempts to elucidate the pathophysiology must consider sleep physiology, as unrefreshing sleep is the most commonly reported of the 8 case-defining symptoms of CFS. Although published studies have consistently reported inefficient sleep and documented a variable occurrence of previously undiagnosed primary sleep disorders, they have not identified characteristic disturbances in sleep architecture or a distinctive pattern of polysomnographic abnormalities associated with CFS. METHODS: This study recruited CFS cases and non-fatigued controls from a population based study of CFS in Wichita, Kansas. Participants spent two nights in the research unit of a local hospital and underwent overnight polysomnographic and daytime multiple sleep latency testing in order to characterize sleep architecture. RESULTS: Approximately 18% of persons with CFS and 7% of asymptomatic controls were diagnosed with severe primary sleep disorders and were excluded from further analysis. These rates were not significantly different. Persons with CFS had a significantly higher mean frequency of obstructive apnea per hour (p = .003); however, the difference was not clinically meaningful. Other characteristics of sleep architecture did not differ between persons with CFS and controls. CONCLUSION: Although disordered breathing during sleep may be associated with CFS, this study generally did not provide evidence that altered sleep architecture is a critical factor in CFS. Future studies should further scrutinize the relationship between subjective sleep quality relative to objective polysomnographic measures

    Obstructive sleep apnoea: A review of the orofacial implications

    Get PDF
    The document attached has been archived with permission from the Australian Dental Association (8th Jan 2008). An external link to the publisher’s copy is included.Obstructive sleep apnoea is a complex multifactorial condition produced by a combination of anatomical and physiological factors. There is a significant associated mortality and morbidity to obstructive sleep apnoea. There is an at least 25 per cent increased mortality from cardiovascular disease when obstructive sleep apnoea patients are compared to age and gender matched healthy people. Obstructive sleep apnoea sufferers also have a much higher industrial and motor vehicle accident rate. Management of the condition should be undertaken by a multidisciplinary team including respiratory physicians, sleep laboratory technicians, otorhinolaryngologists, oral and maxillofacial surgeons and dental specialists. The diagnostic and therapeutic interactions of team members are the key to successful treatment. The treatment regime utilises nasal continuous positive airway pressure devices, mandibular advancement splints and soft and hard tissue surgery. This review provides the dental practitioner with an introduction to obstructive sleep apnoea with particular emphasis on the orofacial aspects.David Sherring, Norman Vowles, Ral Antic, Suren Krishnan and Alastair N Gos

    Interictal Spiking Increases with Sleep Depth in Temporal Lobe Epilepsy

    Full text link
    Purpose : To test the hypothesis that deepening sleep activates focal interictal epileptiform discharges (IEDs), we performed EEG-polysomnography in 21 subjects with medically refractory temporal lobe epilepsy. Methods: At the time of study, subjects were seizure-free for 224 h and were taking stable doses of antiepileptic medications (AEDs). Sleep depth was measured by log delta power (LDP). Visual sleep scoring and visual detection of IEDs also were performed. Logistic-regression analyses of IED occurrence in relation to LDP were carried out for two groups of subjects, nine with frequent IEDs (group 1) and 12 with rare IEDs (group 2). Results: The LDP differentiated visually scored non-rapid eye movement (NREM) sleep stages (p = 0.0001). The IEDs were most frequent in NREM stages 3/4 and least frequent in REM sleep. Within NREM sleep, in both groups, IEDs were more frequent at higher levels of LDP (p < 0.05). In group 1, after accounting for the level of LDP, IEDs were more frequent (a) on the ascending limb of LDP and with more rapid increases in LDP (p = 0.007), (b) in NREM than in REM sleep (p = 0.002), and (c) closer to sleep onset (p < 0.0001). Fewer than 1% of IEDs occurred within 10 s of an EEG arousal. Conclusions: Processes underlying the deepening of NREM sleep, including progressive hyperpolarization in thalamocortical projection neurons, may contribute to IED activation in partial epilepsy. Time from sleep onset and NREM versus REM sleep also influence IED occurrence.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/65422/1/j.1528-1157.1998.tb01329.x.pd

    HLA-DQB1 Allele and Hypocretin in Korean Narcoleptics with Cataplexy

    Get PDF
    Cataplexy is one of the most pathognomonic symptoms in narcolepsy. This study was designed to investigate the frequency of the HLA-DQB1 allele and cerebrospinal fluid (CSF) hypocretin levels in Korean narcoleptics with cataplexy as compared with those who do not have cataplexy. Seventy-two narcoleptics were selected based on polysomnography and multiple sleep latency test as well as their history and clinical symptoms at Sleep Disorders Clinic. The patients were divided into a narcolepsy with cataplexy group (n=56) and a narcolepsy without cataplexy group (n=16). All patients were subjected to HLA typing to determine the frequency of DQB1 allele and to spinal tapping to measure the level of CSF hypocretin. In cataplexy-positive patients, as compared with cataplexy-negative patients, the frequency of HLA-DQB1*0602 was found to be significantly high (89.3% vs. 50.0%) (p=0.003). On the other hand, the frequency of HLA-DQB1*0601 was found to be significantly low (0% vs. 43.8%) (p<0.001). In 48 of 56 cataplexy-positive patients (85.7%), hypocretin levels were decreased (≤110 pg/mL). However, only 6 of 16 cataplexy-negative patients (37.5%) exhibited a decreased hyopcretin level (p<0.001). The high frequency of HLA-DQB1*0602, low frequency of HLA-DQB1*0601 and low hypocretin levels in cataplexy-positive groups suggest that cataplexy-positive narcolepsy might be an etiologically different disease entity from the cataplexy-negative
    corecore