336 research outputs found
Effect of aging on the reinforcement efficiency of carbon nanotubes in epoxy matrix
The reinforcement efficiency of carbon nanotubes (CNTs) in epoxy matrix was
investigated in the elastic regime. Cyclic uniaxial tensile tests were
performed at constant strain amplitude and increasing maximum strain.
Post-curing of the epoxy and its composite at a temperature close to the glass
transition temperature allowed us to explore the effect of aging on the
reinforcement efficiency of CNT. It is found that the reinforcement efficiency
is compatible with a mean field mixture rule of stress reinforcement by random
inclusions. It also diminishes when the maximum strain increased and this
effect is amplified by aging. The decrease of elastic modulus with increasing
cyclic maximum strain is quite similar to the one observed for filled
elastomers with increasing strain amplitude, a phenomenon often referred as the
Payne effect
Diagnosis and localization of fault for a neutral point clamped inverter in wind energy conversion system using artificial neural network technique
Introduction. To attain high efficiency and reliability in the field of clean energy conversion, power electronics play a significant role in a wide range of applications. More effort is being made to increase the dependability of power electronics systems. Purpose. In order to avoid any undesirable effects or disturbances that negatively affect the continuity of service in the field of energy production, this research provides a fault detection technique for insulated-gate bipolar transistor open-circuit faults in a three-level diode-clamped inverter of a wind energy conversion system predicated on a doubly-fed induction generator. The novelty of the suggested work ensures the regulation of power exchanged between the system and the grid without faults, advanced intelligence approaches based on a multilayer artificial neural network are used to discover and locate this type of defect; the database is based on the module and phase angle of three-phase stator currents of induction generators. The proposed methods are designed for the detection of one or two open-circuit faults in the power switches of the side converter of a doubly-fed induction generator in a wind energy conversion system. Methods. In the proposed detection method, only the three-phase stator current module and phase angle are used to identify the faulty switch. The primary goal of this fault diagnosis system is to effectively detect and locate failures in one or even more neutral point clamped inverter switches. Practical value. The performance of the controllers is evaluated under different operating conditions of the power system, and the reliability, feasibility, and effectiveness of the proposed fault detection have been verified under various open-switch fault conditions. The diagnostic approach is also robust to transient conditions posed by changes in load and speed. The proposed diagnostic technique's performance and effectiveness are both proven by simulation in the SimPower /Simulink® MATLAB environment.Вступ. Для досягнення високої ефективності та надійності у галузі чистого перетворення енергії силова електроніка відіграє важливу роль у широкому спектрі застосування. Докладаються зусилля для підвищення надійності систем силової електроніки. Мета. Щоб уникнути будь-яких небажаних ефектів або перешкод, що негативно впливають на безперервність роботи в галузі виробництва енергії, у цьому дослідженні пропонується методика виявлення несправностей біполярних транзисторів із ізольованим затвором при обриві ланцюга в трирівневому інверторі з діодною фіксацією системи перетворення енергії вітру, що ґрунтується на асинхронному генераторі з подвійним живленням. Новизна запропонованої роботи забезпечує регулювання потужності, що обмінюється між системою та мережею, без збоїв, для виявлення та локалізації цього типу дефекту використовуються передові інтелектуальні підходи, засновані на багатошаровій штучній нейронній мережі; база даних заснована на модулі та фазовому куті трифазних статорних струмів асинхронних генераторів. Запропоновані методи призначені для виявлення одного або двох обривів у силових ключах бокового перетворювача асинхронного генератора подвійного живлення у системі перетворення енергії вітру. Методи. У запропонованому методі виявлення для ідентифікації несправного вимикача використовуються тільки трифазний модуль струму статора і фазовий кут. Основною метою цієї системи діагностики несправностей є ефективне виявлення та локалізація відмов в одному або навіть кількох інверторних перемикачах з фіксованою нейтральною точкою. Практична цінність. Робочі характеристики контролерів оцінюються за різних умов роботи енергосистеми, а надійність, здійсненність та ефективність запропонованого виявлення несправностей були перевірені за різних умов відмови розімкнутого вимикача. Діагностичний підхід також стійкий до перехідних станів, спричинених змінами навантаження та швидкості. Продуктивність та ефективність запропонованого діагностичного методу підтверджені моделюванням у середовищі SimPower/Simulink® MATLAB
Thérapies traditionnelles aux Comores
Cet article présente un tableau général des divers moyens de protection des dangers et de guérison des maux, mis en oeuvre dans la société comorienne. Islamisée de façon continue depuis des siècles, cette société développe aussi une vision populaire du monde et des pratiques magico-religieuses plus ou moins tolérées par l'indulgence de l'islam local. Religion et pratiques populaires ont été elles-mêmes apportées par des groupes de population d'origine africaine, indonésienne, arabe ou malgache, qui ont juxtaposé ou mêlé divers systèmes de représentations. Leurs points communs sont : une vision déterminée d'un monde dominé par des déséquilibres et des concordances à respecter, justifiant l'observance de l'astrologie et le respect d'interdits; un relativisme social qui attribue à l'autre les intentions malveillantes qui ont provoqué le mal, les désordres et les problèmes qui affectent l'être humain, ou sa famille, dans sa vie quotidienne. (Résumé d'auteur
Purifying Performance of the STEP of Mrirt (Natural lagoon)
AbstractThe purifying system of the domestic lagoon sewage remains one of the most widely used processes in Morocco (81% of lagoon-type wastewater treatment plants) since it is the most technical solution which is suited to the economic and climatic conditions of our country.Throughout this work, we tended to study the purifying performance of the wastewater treatment plant in the town of Mrirt, by measuring the parameters, which indicate the pollution degree, namely BOD5, COD and TSS. According to the results obtained from those parameters, we determined the causes of the non-conformity of rejection for the global parameters of pollution with respect to the unfiltered samples and proposed the solutions for the good purification of the STEP with a tertiary treatment, which is based on the physicochemical methods of the water discharged into the natural environments.In the light of this work, the monthly results throughout the last two years (2012-2013) concerning the parameters of the raw and purified wastewater studied and discharged from the town of Mrirt have shown that:* The average BOD5 which is recorded at the inlet and the outlet of the STEP is respectively 575 mg O2 / l and 159 mg O2 / l.* The average TSS which is recorded at the inlet is 450 mg / l and at the outlet is 169 mg / l* The average COD, which is recorded at the inlet and the outlet, is respectively 1015 mg O2 / l and 169 mg O2 / l.On the basis of the obtained results, it can be said that the most suitable kind of the natural lagooning process in Morocco (the town of Mrirt) remains very sensitive to the various factors influencing the effluent yield of the STEP such as the accumulation of sludge at the level of the anaerobic basins, the climate change out of the seasons (temperature variation), residence period, volumetric and superficial load, the algal development ...etc.
Malakoplakie pseudotumorale du sein
La malakoplakie est une maladie inflammatoire granulomateuse chronique, qui affecte généralement le tractus génito-urinaire et exceptionnellement la glande mammaire. Il faut savoir évoquer ce diagnostic devant une mastite pseudotumorale. Sa définition est anatomopathologique. Nous rapportons un cas inhabituel de malakoplakie mammaire chez une patiente ayant des antécédents de tuberculose. L'imagerie était en faveur d'une mastite carcinomateuse. L'analyse histologique de la biopsie mammaire révélait une inflammation granulomateuse faite d'histiocytes renfermant des granulations pathognomoniques de Michaelis-Gutmann. La patiente était mise sous traitement médical à base de ciprofloxacine avec bonne évolution clinique et radiologique après un recul d'un mois
Fault diagnosis of power converters in a grid connected photovoltaic system using artificial neural networks
Introduction. The widespread use of photovoltaic systems in various applications has spotlighted the pressing requirement for reliability, efficiency and continuity of service. The main impediment to a more effective implementation has been the reliability of the power converters. Indeed, the presence of faults in power converters that can cause malfunctions in the photovoltaic system, which can reduce its performance. Novelty. This paper presents a technique for diagnosing open circuit failures in the switches (IGBTs) of power converters (DC-DC converters and three-phase inverters) in a grid-connected photovoltaic system. Purpose. To ensure supply continuity, a fault-diagnosis process is required throughout all phases of energy production, transfer, and conversion. Methods. The diagnostic approach is based on artificial neural networks and the extraction of features corresponding to the open circuit fault of the IGBT switch. This approach is based on the Clarke transformation of the three-phase currents of the inverter output as well as the calculation of the average value of these currents to determine the exact angle of the open circuit fault. Results. This method is able to effectively identify and localize single or multiple open circuit faults of the DC-DC converter IGBT switch or the three-phase inverter IGBT switches.Вступ. Широке використання фотоелектричних систем у різних застосуваннях висунуло на перший план нагальні вимоги до надійності, ефективності та безперервності обслуговування. Основною перешкодою для ефективнішого застосування була надійність силових перетворювачів. Справді, наявність несправностей у силових перетворювачах може спричинити збої в роботі фотоелектричної системи, що може знизити її продуктивність. Новизна. У цій статті представлена методика діагностики обриву кола в перемикачах (IGBT) силових перетворювачів (перетворювачів постійного струму та трифазних інверторів) у фотоелектричній системі, підключеній до мережі. Мета. Для забезпечення безперервності постачання потрібен процес діагностики несправностей на всіх етапах виробництва, передачі та перетворення енергії. Методи. Діагностичний підхід заснований на штучних нейронних мережах та вилучення ознак, що відповідають обриву кола IGBT-перемикача. Цей підхід ґрунтується на перетворенні Кларка трифазних струмів на виході інвертора, а т акож розрахунку середнього значення цих струмів для визначення точного кута обриву кола. Результати. Цей метод дозволяє ефективно ідентифікувати та локалізувати одиночні або множинні несправності розімкнутого кола IGBT-перемикача DC-DC перетворювача або IGBT-перемикача трифазного інвертора
- …