47 research outputs found

    Vancomycin therapy in critically ill patients on continuous renal replacement therapy; are we doing enough?

    Get PDF
    AbstractBackgroundRecommendations regarding vancomycin dosing and monitoring in critically ill patients on continuous renal replacement therapy (CRRT) are limited. This is a retrospective study to assess the adequacy of current vancomycin dosing and monitoring practice for patients on CRRT in a tertiary hospital in Riyadh, Saudi Arabia.MethodsA retrospective chart review of adult patients admitted between 1 April 2011 and 30 March 2013 to critical care and received intravenous vancomycin therapy whilst on CRRT was performed.ResultsA total of 68 patients received intravenous vancomycin therapy whilst on CRRT, of which 32 met the inclusion criteria. Fifty-one percent were males and median (range) age was 62.5 (19 – 90) years. Median APACHE II score was 33.5 (22–43) and median Charlson Comorbidity Score was 4 (0–8). The mean (±standard deviation) dose of vancomycin was 879.9mg (±281.2mg) for an average duration of 5.9days (±3.7days). All patients received continuous veno-venous haemofiltration (CVVH). A total of 55 vancomycin level readings were available from the study population, ranging from 6.6 to 41.3, with wide variations within the same sampling time frames. Vancomycin levels of>15mg/L or were achieved at least once in 24 patients (75.0%), but only 11 patients (34.3%) had 2 or more serum vancomycin level readings of 15mg/L or more.ConclusionTherapeutic vancomycin levels are difficult to maintain in critically ill patients who are receiving IV vancomycin therapy whilst on CRRT. Aggressive dosing schedules and frequent monitoring are required to ensure adequate vancomycin therapy in this setting

    Viral shedding and antibody response in 37 patients with MERS-coronavirus infection

    Get PDF
    Background. The Middle East respiratory syndrome (MERS) coronavirus causes isolated cases and outbreaks of severe respiratory disease. Essential features of the natural history of disease are poorly understood. Methods. We studied 37 adult patients infected with MERS coronavirus for viral load in the lower and upper respiratory tracts (LRT and URT, respectively), blood, stool, and urine. Antibodies and serum neutralizing activities were determined over the course of disease. Results. One hundred ninety-nine LRT samples collected during the 3 weeks following diagnosis yielded virus RNA in 93% of tests. Average (maximum) viral loads were 5 × 106 (6 × 1010) copies/mL. Viral loads (positive detection frequencies) in 84 URT samples were 1.9 × 104 copies/mL (47.6%). Thirty-three percent of all 108 serum samples tested yielded viral RNA. Only 14.6% of stool and 2.4% of urine samples yielded viral RNA. All seroconversions occurred during the first 2 weeks after diagnosis, which corresponds to the second and third week after symptom onset. Immunoglobulin M detection provided no advantage in sensitivity over immunoglobulin G (IgG) detection. All surviving patients, but only slightly more than half of all fatal cases, produced IgG and neutralizing antibodies. The levels of IgG and neutralizing antibodies were weakly and inversely correlated with LRT viral loads. Presence of antibodies did not lead to the elimination of virus from LRT. Conclusions. The timing and intensity of respiratory viral shedding in patients with MERS closely matches that of those with severe acute respiratory syndrome. Blood viral RNA does not seem to be infectious. Extrapulmonary loci of virus replication seem possible. Neutralizing antibodies do not suffice to clear the infection

    Steady improvement of infection control services in six community hospitals in Makkah following annual audits during Hajj for four consecutive years

    Get PDF
    BACKGROUND: the objective of this study was to evaluate the impact of annual review of the infection control practice in all Ministry of Health hospitals in the holy city of Makkah, Saudi Arabia, during the Hajj period of four lunar Islamic years, 1423 to 1426 corresponding to 2003 to 2006. METHODS: audit of infection control service was conducted annually over a 10-day period in six community hospitals with bed capacities ranging from 140 to 557 beds. Data were collected on standardized checklists on various infection control service items during surprise visits to the medical, pediatric, surgical, and critical care units, and the kitchens. Percentage scores were calculated for audited items. The results of the audit for hospitals were confidentially sent to them within four weeks after the end of Hajj. RESULTS: deficiencies observed in the first audit included lack of infection control committees, infection control units, infection control educational activities, and surveillance system and shortage of staff. These deficiencies were resolved in the subsequent audits. The average (range) scores of hospitals in 11 infection control items increased from 43% (20–67%) in the first audit to 78% (61–93%) in the fourth audit. CONCLUSION: regular hospital infection control audits lead to significant improvement of infection control practice. There is a need to build a rigorous infection control audit into hospitals' ongoing monitoring and reporting to the Ministry of Health and to provide these hospitals with feed back on such audits to continuously strengthen the safety standards for patients, visitors, and employees

    An Adaptive Early Stopping Technique for DenseNet169-Based Knee Osteoarthritis Detection Model

    Get PDF
    Knee osteoarthritis (OA) detection is an important area of research in health informatics that aims to improve the accuracy of diagnosing this debilitating condition. In this paper, we investigate the ability of DenseNet169, a deep convolutional neural network architecture, for knee osteoarthritis detection using X-ray images. We focus on the use of the DenseNet169 architecture and propose an adaptive early stopping technique that utilizes gradual cross-entropy loss estimation. The proposed approach allows for the efficient selection of the optimal number of training epochs, thus preventing overfitting. To achieve the goal of this study, the adaptive early stopping mechanism that observes the validation accuracy as a threshold was designed. Then, the gradual cross-entropy (GCE) loss estimation technique was developed and integrated to the epoch training mechanism. Both adaptive early stopping and GCE were incorporated into the DenseNet169 for the OA detection model. The performance of the model was measured using several metrics including accuracy, precision, and recall. The obtained results were compared with those obtained from the existing works. The comparison shows that the proposed model outperformed the existing solutions in terms of accuracy, precision, recall, and loss performance, which indicates that the adaptive early stopping coupled with GCE improved the ability of DenseNet169 to accurately detect knee OA

    Presentation and outcome of Middle East respiratory syndrome in Saudi intensive care unit patients.

    Get PDF
    BACKGROUND: Middle East respiratory syndrome coronavirus infection is associated with high mortality rates but limited clinical data have been reported. We describe the clinical features and outcomes of patients admitted to an intensive care unit (ICU) with Middle East respiratory syndrome coronavirus (MERS-CoV) infection. METHODS: Retrospective analysis of data from all adult (>18 years old) patients admitted to our 20-bed mixed ICU with Middle East respiratory syndrome coronavirus infection between October 1, 2012 and May 31, 2014. Diagnosis was confirmed in all patients using real-time reverse transcription polymerase chain reaction on respiratory samples. RESULTS: During the observation period, 31 patients were admitted with MERS-CoV infection (mean age 59 ± 20 years, 22 [71 %] males). Cough and tachypnea were reported in all patients; 22 (77.4 %) patients had bilateral pulmonary infiltrates. Invasive mechanical ventilation was applied in 27 (87.1 %) and vasopressor therapy in 25 (80.6 %) patients during the intensive care unit stay. Twenty-three (74.2 %) patients died in the ICU. Nonsurvivors were older, had greater APACHE II and SOFA scores on admission, and were more likely to have received invasive mechanical ventilation and vasopressor therapy. After adjustment for the severity of illness and the degree of organ dysfunction, the need for vasopressors was an independent risk factor for death in the ICU (odds ratio = 18.33, 95 % confidence interval: 1.11-302.1, P = 0.04). CONCLUSIONS: MERS-CoV infection requiring admission to the ICU is associated with high morbidity and mortality. The need for vasopressor therapy is the main risk factor for death in these patients

    Estimating potential incidence of MERS-CoV associated with Hajj pilgrims to Saudi Arabia, 2014

    Get PDF
    Between March and June 2014 the Kingdom of Saudi Arabia (KSA) had a large outbreak of MERS-CoV, renewing fears of a major outbreak during the Hajj this October. Using KSA Ministry of Health data, the MERS-CoV Scenario and Modeling Working Group forecast incidence under three scenarios. In the expected incidence scenario, we estimate 6.2 (95% Prediction Interval [PI]: 1-17) pilgrims will develop MERS-CoV symptoms during the Hajj, and 4.0 (95% PI: 0-12) foreign pilgrims will be infected but return home before developing symptoms. In the most pessimistic scenario, 47.6 (95% PI: 32-66) cases will develop symptoms during the Hajj, and 29.0 (95% PI: 17-43) will be infected but return home asymptomatic. Large numbers of MERS-CoV cases are unlikely to occur during the 2014 Hajj even under pessimistic assumptions, but careful monitoring is still needed to detect possible mass infection events and minimize introductions into other countries

    Geoeconomic variations in epidemiology, ventilation management, and outcomes in invasively ventilated intensive care unit patients without acute respiratory distress syndrome: a pooled analysis of four observational studies

    Get PDF
    Background: Geoeconomic variations in epidemiology, the practice of ventilation, and outcome in invasively ventilated intensive care unit (ICU) patients without acute respiratory distress syndrome (ARDS) remain unexplored. In this analysis we aim to address these gaps using individual patient data of four large observational studies. Methods: In this pooled analysis we harmonised individual patient data from the ERICC, LUNG SAFE, PRoVENT, and PRoVENT-iMiC prospective observational studies, which were conducted from June, 2011, to December, 2018, in 534 ICUs in 54 countries. We used the 2016 World Bank classification to define two geoeconomic regions: middle-income countries (MICs) and high-income countries (HICs). ARDS was defined according to the Berlin criteria. Descriptive statistics were used to compare patients in MICs versus HICs. The primary outcome was the use of low tidal volume ventilation (LTVV) for the first 3 days of mechanical ventilation. Secondary outcomes were key ventilation parameters (tidal volume size, positive end-expiratory pressure, fraction of inspired oxygen, peak pressure, plateau pressure, driving pressure, and respiratory rate), patient characteristics, the risk for and actual development of acute respiratory distress syndrome after the first day of ventilation, duration of ventilation, ICU length of stay, and ICU mortality. Findings: Of the 7608 patients included in the original studies, this analysis included 3852 patients without ARDS, of whom 2345 were from MICs and 1507 were from HICs. Patients in MICs were younger, shorter and with a slightly lower body-mass index, more often had diabetes and active cancer, but less often chronic obstructive pulmonary disease and heart failure than patients from HICs. Sequential organ failure assessment scores were similar in MICs and HICs. Use of LTVV in MICs and HICs was comparable (42\ub74% vs 44\ub72%; absolute difference \u20131\ub769 [\u20139\ub758 to 6\ub711] p=0\ub767; data available in 3174 [82%] of 3852 patients). The median applied positive end expiratory pressure was lower in MICs than in HICs (5 [IQR 5\u20138] vs 6 [5\u20138] cm H2O; p=0\ub70011). ICU mortality was higher in MICs than in HICs (30\ub75% vs 19\ub79%; p=0\ub70004; adjusted effect 16\ub741% [95% CI 9\ub752\u201323\ub752]; p<0\ub70001) and was inversely associated with gross domestic product (adjusted odds ratio for a US$10 000 increase per capita 0\ub780 [95% CI 0\ub775\u20130\ub786]; p<0\ub70001). Interpretation: Despite similar disease severity and ventilation management, ICU mortality in patients without ARDS is higher in MICs than in HICs, with a strong association with country-level economic status. Funding: No funding

    Hyperoxemia and excess oxygen use in early acute respiratory distress syndrome : Insights from the LUNG SAFE study

    Get PDF
    Publisher Copyright: © 2020 The Author(s). Copyright: Copyright 2020 Elsevier B.V., All rights reserved.Background: Concerns exist regarding the prevalence and impact of unnecessary oxygen use in patients with acute respiratory distress syndrome (ARDS). We examined this issue in patients with ARDS enrolled in the Large observational study to UNderstand the Global impact of Severe Acute respiratory FailurE (LUNG SAFE) study. Methods: In this secondary analysis of the LUNG SAFE study, we wished to determine the prevalence and the outcomes associated with hyperoxemia on day 1, sustained hyperoxemia, and excessive oxygen use in patients with early ARDS. Patients who fulfilled criteria of ARDS on day 1 and day 2 of acute hypoxemic respiratory failure were categorized based on the presence of hyperoxemia (PaO2 > 100 mmHg) on day 1, sustained (i.e., present on day 1 and day 2) hyperoxemia, or excessive oxygen use (FIO2 ≥ 0.60 during hyperoxemia). Results: Of 2005 patients that met the inclusion criteria, 131 (6.5%) were hypoxemic (PaO2 < 55 mmHg), 607 (30%) had hyperoxemia on day 1, and 250 (12%) had sustained hyperoxemia. Excess FIO2 use occurred in 400 (66%) out of 607 patients with hyperoxemia. Excess FIO2 use decreased from day 1 to day 2 of ARDS, with most hyperoxemic patients on day 2 receiving relatively low FIO2. Multivariate analyses found no independent relationship between day 1 hyperoxemia, sustained hyperoxemia, or excess FIO2 use and adverse clinical outcomes. Mortality was 42% in patients with excess FIO2 use, compared to 39% in a propensity-matched sample of normoxemic (PaO2 55-100 mmHg) patients (P = 0.47). Conclusions: Hyperoxemia and excess oxygen use are both prevalent in early ARDS but are most often non-sustained. No relationship was found between hyperoxemia or excessive oxygen use and patient outcome in this cohort. Trial registration: LUNG-SAFE is registered with ClinicalTrials.gov, NCT02010073publishersversionPeer reviewe

    Smart piezoelectric-based wearable system for calorie intake estimation using machine learning

    Get PDF
    Eating an appropriate food volume, maintaining the required calorie count, and making good nutritional choices are key factors for reducing the risk of obesity, which has many consequences such as Osteoarthritis (OA) that affects the patient’s knee. In this paper, we present a wearable sensor in the form of a necklace embedded with a piezoelectric sensor, that detects skin movement from the lower trachea while eating. In contrast to the previous state-of-the-art piezoelectric sensor-based system that used spectral features, our system fully exploits temporal amplitude-varying signals for optimal features, and thus classifies foods more accurately. Through evaluation of the frame length and the position of swallowing in the frame, we found the best performance was with a frame length of 30 samples (1.5 s), with swallowing located towards the end of the frame. This demonstrates that the chewing sequence carries important information for classification. Additionally, we present a new approach in which the weight of solid food can be estimated from the swallow count, and the calorie count of food can be calculated from their estimated weight. Our system based on a smartphone app helps users live healthily by providing them with real-time feedback about their ingested food types, volume, and calorie count
    corecore