92 research outputs found

    Surveillance of Airborne Adenovirus and Mycoplasma pneumoniae in a Hospital Pediatric Department

    Get PDF
    This investigation evaluated the distributions of airborne adenovirus and Mycoplasma pneumoniae in public areas in the pediatric department of Children's Hospital in northern Taiwan. The airborne viral and bacterial concentrations were evaluated twice a week for a year using filter sampling with an airflow rate of 12 liters per minute for eight hours in the pediatric outpatient department and 24 hours in the pediatric emergency room. Real-time polymerase chain reaction assays were conducted for analysis. Approximately 18% of the air samples from the pediatric emergency room were found to contain adenovirus. Approximately forty-six percent of the air samples from the pediatric outpatient department contained Mycoplasma pneumoniae DNA products. High detection rates of airborne adenovirus DNA were obtained in July and August in the pediatric public areas. Airborne Mycoplasma pneumoniae was detected only in July in the pediatric emergency room and the peak levels were found from August to January in the pediatric outpatient department. Airborne particles that contained adenovirus and Mycoplasma pneumoniae were the most prevalent in the pediatric public areas. The potential relationship between these airborne viral/bacterial particles and human infection should be examined further

    Airborne rhinovirus detection and effect of ultraviolet irradiation on detection by a semi-nested RT-PCR assay

    Get PDF
    BACKGROUND: Rhinovirus, the most common cause of upper respiratory tract infections, has been implicated in asthma exacerbations and possibly asthma deaths. Although the method of transmission of rhinoviruses is disputed, several studies have demonstrated that aerosol transmission is a likely method of transmission among adults. As a first step in studies of possible airborne rhinovirus transmission, we developed methods to detect aerosolized rhinovirus by extending existing technology for detecting infectious agents in nasal specimens. METHODS: We aerosolized rhinovirus in a small aerosol chamber. Experiments were conducted with decreasing concentrations of rhinovirus. To determine the effect of UV irradiation on detection of rhinoviral aerosols, we also conducted experiments in which we exposed aerosols to a UV dose of 684 mJ/m(2). Aerosols were collected on Teflon filters and rhinovirus recovered in Qiagen AVL buffer using the Qiagen QIAamp Viral RNA Kit (Qiagen Corp., Valencia, California) followed by semi-nested RT-PCR and detection by gel electrophoresis. RESULTS: We obtained positive results from filter samples that had collected at least 1.3 TCID(50 )of aerosolized rhinovirus. Ultraviolet irradiation of airborne virus at doses much greater than those used in upper-room UV germicidal irradiation applications did not inhibit subsequent detection with the RT-PCR assay. CONCLUSION: The air sampling and extraction methodology developed in this study should be applicable to the detection of rhinovirus and other airborne viruses in the indoor air of offices and schools. This method, however, cannot distinguish UV inactivated virus from infectious viral particles

    Novel insights into an old controversy: Is coronary artery ectasia a variant of coronary atherosclerosis?

    Get PDF
    Coronary artery ectasia (CAE) is defined as a localized or diffuse non-obstructive lesion of the epicardial coronary arteries with a luminal dilation exceeding 1.5-fold the diameter of the normal adjacent arterial segment. The incidence of CAE has been reported to range between 2% and 4%, which might be an overestimation of the true frequency. The coincidence of CAE with other systemic vascular dilatations has suggested that the mechanism underlying CAE is not only localized to coronary arteries, but also to other vascular compartments such as aorta or peripheral veins. Although the pathophysiology of CAE remains largely unknown, it was supposed to represent a variant of coronary atherosclerosis. This review focuses on this controversy of whether CAE and coronary artery disease (CAD) are two manifestations of the same underlying process. There are clear differences between CAD and CAE with respect to cardiovascular risk factors such as diabetes mellitus, and pathogenic steps in disease progress such as inflammation or extracellular matrix remodeling. As this review will underscore, the current knowledge of the field is insufficient to finally clarify the causative interrelation between CAE and CAD. The clinical course and treatment of CAE mainly depends on its coexistence with CAD. When coexisting with CAD, the prognosis and treatment of CAE are the same as for CAD alone. In isolated CAE, prognosis is better and anti-platelet drugs are the mainstay of treatment. Surgical treatment can be considered in selected patients. For clarifying the mechanism underlying CAE, additional clinical, histopathological and pathophysiological investigations are required. In fact, every patient with CAE should be evaluated systematically for pathological changes in other vascular territories, both in the arterial system as well as in the venous system, which might occur in the disease process

    Prevalence and morphology of coronary artery ectasia with dual-source CT coronary angiography

    Full text link
    To assess the prevalence and morphological characteristics of coronary artery ectasia (CAE) with CT coronary angiography (CTCA) in comparison to conventional catheterangiography (CCA). Dual-source CTCA examinations from 677 consecutive patients (223 women; median age 57 years) were retrospectively evaluated by two blinded observers for the presence of CAE defined as a diameter enlargement >/=1.5 times the diameter of adjacent normal coronary segments. Vessel diameters and contrast attenuation within and proximal to ectatic segments were measured. CCA was used to compare measurements obtained from CTCA with the coronary flow velocity by using the thrombolysis in myocardial infarction (TIMI) frame count. CTCA identified CAE in 20 of 677 (3%) patients. CCA was performed in ten of these patients. CAE diameter measurements with CTCA (10.0 +/- 5.4 mm) correlated significantly (r = 0.92, p < 0.001) with the CCA measurements (8.8 +/- 4.9 mm), but had higher diameters (levels of agreement: -1.0 to 3.4 mm). Contrast attenuation was significantly lower in the ectatic (343 +/- 63 HU) than in the proximal (394 +/- 60 HU) segments (p < 0.01). The attenuation difference significantly correlated with the CAE ratio (r = 0.67, p < 0.01) and the TIMI frame count (r = 0.58, p < 0.05). The prevalence of CAE in a population examined by CTCA is around 3%. Contrast attenuation measurements with CTCA correlate well with the flow alterations assessed with CCA

    Graduate recitals

    No full text
    [no abstract]Arts, Faculty ofMusic, School ofGraduat
    • …
    corecore