11,087 research outputs found

    ILC Beam Energy Measurement by means of Laser Compton Backscattering

    Full text link
    A novel, non-invasive method of measuring the beam energy at the International Linear Collider is proposed. Laser light collides head-on with beam particles and either the energy of the Compton scattered electrons near the kinematic end-point is measured or the positions of the Compton backscattered γ\gamma-rays, the edge electrons and the unscattered beam particles are recorded. A compact layout for the Compton spectrometer is suggested. It consists of a bending magnet and position sensitive detectors operating in a large radiation environment. Several options for high spatial resolution detectors are discussed. Simulation studies support the use of an infrared or green laser and quartz fiber detectors to monitor the backscattered photons and edge electrons. Employing a cavity monitor, the beam particle position downstream of the magnet can be recorded with submicrometer precision. Such a scheme provides a feasible and promising method to access the incident beam energy with precisions of 10−410^{-4} or better on a bunch-to-bunch basis while the electron and positron beams are in collision.Comment: 47 pages, 26 figures, version as accepted by Nucl. Instr. Meth. A after improvement

    A Medial Congruent Polyethylene Offers Satisfactory Early Outcomes and Patient Satisfaction in Total Knee Arthroplasty

    Get PDF
    Background Although a successful operation, almost 20% of patients are dissatisfied with total knee arthroplasty (TKA). The purpose of this retrospective cohort study was to see if a medial congruent (MC) polyethylene would offer satisfactory early outcomes and patient satisfaction after TKA. Methods We reviewed prospectively collected data on 327 TKAs using multiple bearings within the same implant system. Ninety-six received an MC bearing, 70 received a cruciate-retaining (CR) bearing, and 161 received a posterior-stabilized (PS) bearing. We evaluated the visual analog scale pain scores and range of motion (ROM) at 2 weeks, 6 weeks, 3 months, and 1 year; Patient-Reported Outcomes Measurement Information System (PROMIS-10) score and Knee Injury and Osteoarthritis Outcome Score (KOOS) at 3 months and 1 year; and Forgotten Joint Score (FJS-12) at 1 year. Results All groups had similar KOOS and PROMIS-10 scores. MC knees had lower visual analog scale scores than PS knees at all time points (P \u3c .05) and a higher ROM than PS at 2 weeks (98.6 vs 93.7, P = .002). MC knees had a significantly higher FJS-12 than CR knees (71.6 vs 58.7, P = .02). More MC knees were “very satisfied” than CR (92.6% vs 81.5%, P = .04). Fewer MC knees were “not at all satisfied” than CR (1.2% vs 9.2%, P = .04). There were similar satisfaction ratings with MC and PS. Conclusions An MC bearing provided similar or improved early pain, ROM, KOOS, PROMIS-10, FJS-12, and patient satisfaction as compared with standard bearings in TKA

    Understanding disease control: influence of epidemiological and economic factors

    Get PDF
    We present a local spread model of disease transmission on a regular network and compare different control options ranging from treating the whole population to local control in a well-defined neighborhood of an infectious individual. Comparison is based on a total cost of epidemic, including cost of palliative treatment of ill individuals and preventive cost aimed at vaccination or culling of susceptible individuals. Disease is characterized by pre- symptomatic phase which makes detection and control difficult. Three general strategies emerge, global preventive treatment, local treatment within a neighborhood of certain size and only palliative treatment with no prevention. The choice between the strategies depends on relative costs of palliative and preventive treatment. The details of the local strategy and in particular the size of the optimal treatment neighborhood weakly depends on disease infectivity but strongly depends on other epidemiological factors. The required extend of prevention is proportional to the size of the infection neighborhood, but this relationship depends on time till detection and time till treatment in a non-nonlinear (power) law. In addition, we show that the optimal size of control neighborhood is highly sensitive to the relative cost, particularly for inefficient detection and control application. These results have important consequences for design of prevention strategies aiming at emerging diseases for which parameters are not known in advance

    Validation of Kalman Filter alignment algorithm with cosmic-ray data using a CMS silicon strip tracker endcap

    Full text link
    A Kalman Filter alignment algorithm has been applied to cosmic-ray data. We discuss the alignment algorithm and an experiment-independent implementation including outlier rejection and treatment of weakly determined parameters. Using this implementation, the algorithm has been applied to data recorded with one CMS silicon tracker endcap. Results are compared to both photogrammetry measurements and data obtained from a dedicated hardware alignment system, and good agreement is observed.Comment: 11 pages, 8 figures. CMS NOTE-2010/00

    CfAIR2: Near Infrared Light Curves of 94 Type Ia Supernovae

    Get PDF
    CfAIR2 is a large homogeneously reduced set of near-infrared (NIR) light curves for Type Ia supernovae (SN Ia) obtained with the 1.3m Peters Automated InfraRed Imaging TELescope (PAIRITEL). This data set includes 4607 measurements of 94 SN Ia and 4 additional SN Iax observed from 2005-2011 at the Fred Lawrence Whipple Observatory on Mount Hopkins, Arizona. CfAIR2 includes JHKs photometric measurements for 88 normal and 6 spectroscopically peculiar SN Ia in the nearby universe, with a median redshift of z~0.021 for the normal SN Ia. CfAIR2 data span the range from -13 days to +127 days from B-band maximum. More than half of the light curves begin before the time of maximum and the coverage typically contains ~13-18 epochs of observation, depending on the filter. We present extensive tests that verify the fidelity of the CfAIR2 data pipeline, including comparison to the excellent data of the Carnegie Supernova Project. CfAIR2 contributes to a firm local anchor for supernova cosmology studies in the NIR. Because SN Ia are more nearly standard candles in the NIR and are less vulnerable to the vexing problems of extinction by dust, CfAIR2 will help the supernova cosmology community develop more precise and accurate extragalactic distance probes to improve our knowledge of cosmological parameters, including dark energy and its potential time variation.Comment: 31 pages, 15 figures, 10 tables. Accepted to ApJS. v2 modified to more closely match journal versio

    Negotiating the inhuman: Bakhtin, materiality and the instrumentalization of climate change

    Get PDF
    The article argues that the work of literary theorist Mikhail M. Bakhtin presents a starting point for thinking about the instrumentalization of climate change. Bakhtin’s conceptualization of human–world relationships, encapsulated in the concept of ‘cosmic terror’, places a strong focus on our perception of the ‘inhuman’. Suggesting a link between the perceived alienness and instability of the world and in the exploitation of the resulting fear of change by political and religious forces, Bakhtin asserts that the latter can only be resisted if our desire for a false stability in the world is overcome. The key to this overcoming of fear, for him, lies in recognizing and confronting the worldly relations of the human body. This consciousness represents the beginning of one’s ‘deautomatization’ from following established patterns of reactions to predicted or real changes. In the vein of several theorists and artists of his time who explored similar ‘deautomatization’ strategies – examples include Shklovsky’s ‘ostranenie’, Brecht’s ‘Verfremdung’, Artaud’s emotional ‘cruelty’ and Bataille’s ‘base materialism’ – Bakhtin proposes a more playful and widely accessible experimentation to deconstruct our ‘habitual picture of the world’. Experimentation is envisioned to take place across the material and the textual to increase possibilities for action. Through engaging with Bakhtin’s ideas, this article seeks to draw attention to relations between the imagination of the world and political agency, and the need to include these relations in our own experiments with creating climate change awareness

    Lineshape of the Lambda(1405) Hyperon Measured Through its Sigma0 pion0 Decay

    Get PDF
    The pp -> p K+ Y0 reaction has been studied for hyperon masses m(Y0)<1540 MeV/c2 at COSY-Juelich by using a 3.65 GeV/c circulating proton beam incident on an internal hydrogen target. Final states comprising two protons, one positively charged kaon and one negatively charged pion have been identified with the ANKE spectrometer. Such configurations are sensitive to the production of the ground state Lambda and Sigma0 hyperons as well as the Sigma0(1385) and Lambda(1405) resonances. Applying invariant- and missing-mass techniques, the two overlapping excited states could be well separated, though with limited statistics. The shape and position of the Lambda(1405) distribution, reconstructed cleanly in the Sigma0 pion0 channel, are similar to those found from other decay modes and there is no obvious mass shift. This finding constitutes a challenging test for models that predict Lambda(1405) to be a two-state resonance.Comment: 10 pages, 4 figures, accepted for publication in Phys. Lett.
    • 

    corecore