896 research outputs found

    Gravitational-wave astrophysics with effective-spin measurements: asymmetries and selection biases

    Get PDF
    Gravitational waves emitted by coalescing compact objects carry information about the spin of the individual bodies. However, with present detectors only the mass-weighted combination of the components of the spin along the orbital angular momentum can be measured accurately. This quantity, the effective spin χeff\chi_{\mathrm{eff}}, is conserved up to at least the second post-Newtonian order. The measured distribution of χeff\chi_{\mathrm{eff}} values from a population of detected binaries, and in particular whether this distribution is symmetric about zero, encodes valuable information about the underlying compact-binary formation channels. In this paper we focus on two important complications of using the effective spin to study astrophysical population properties: (i) an astrophysical distribution for χeff\chi_{\mathrm{eff}} values which is symmetric does not necessarily lead to a symmetric distribution for the detected effective spin values, leading to a \emph{selection bias}; and (ii) the posterior distribution of χeff\chi_{\mathrm{eff}} for individual events is \emph{asymmetric} and it cannot usually be treated as a Gaussian. We find that the posterior distributions for χeff\chi_{\mathrm{eff}} systematically show fatter tails toward larger positive values, unless the total mass is large or the mass ratio m2/m1m_2/m_1 is smaller than 1/2\sim 1/2. Finally we show that uncertainties in the measurement of χeff\chi_{\mathrm{eff}} are systematically larger when the true value is negative than when it is positive. All these factors can bias astrophysical inference about the population when we have more than 100\sim 100 events and should be taken into account when using gravitational-wave measurements to characterize astrophysical populations.Comment: An online generator for synthetic χeff\chi_{\mathrm{eff}} posteriors can be found at: http://superstring.mit.edu/welcome.html Comments are welcom

    An inkjet printed, roll-coated digital microfluidic device for inexpensive, miniaturized diagnostic assays

    Get PDF
    The diagnosis of infectious disease is typically carried out at the point-of-care (POC) using the lateral flow assay (LFA). While cost-effective and portable, LFAs often lack the clinical sensitivity and specificity required for accurate diagnoses. In response to this challenge, we introduce a new digital microfluidic (DMF) platform fabricated using a custom inkjet printing and roll-coating process that is scalable to mass production. The performance of the new devices is on par with that of traditional DMF devices fabricated in a cleanroom, with a materials cost for the new devices of only US $0.63 per device. To evaluate the usefulness of the new platform, we performed a 13-step rubella virus (RV) IgG immunoassay on the inkjet printed, roll-coated devices, which yielded a limit of detection of 0.02 IU mL^(−1), well below the diagnostic cut-off of 10 IU mL^(−1) for RV infection and immunity. We propose that this represents a breakthrough for DMF, lowering the costs to a level such that the new platforms will be an attractive alternative to LFAs for the diagnosis of infectious disease at the POC

    Electrochemiluminescence on digital microfluidics for microRNA analysis

    Get PDF
    Electrochemiluminescence (ECL) is a sensitive analytical technique with great promise for biological applications, especially when combined with microfluidics. Here, we report the first integration of ECL with digital microfluidics (DMF). ECL detectors were fabricated into the ITO-coated top plates of DMF devices, allowing for the generation of light from electrically excited luminophores in sample droplets. The new system was characterized by making electrochemical and ECL measurements of soluble mixtures of tris(phenanthroline)ruthenium(II) and tripropylamine (TPA) solutions. The system was then validated by application to an oligonucleotide hybridization assay, using magnetic particles bearing 21-mer, deoxyribose analogues of the complement to microRNA-143 (miRNA-143). The system detects single nucleotide mismatches with high specificity, and has a limit of detection of 1.5 femtomoles. The system is capable of detecting miRNA-143 in cancer cell lysates, allowing for the discrimination between the MCF-7 (less aggressive) and MDA-MB-231 (more aggressive) cell lines. We propose that DMF-ECL represents a valuable new tool in the microfluidics toolbox for a wide variety of applications

    OpenContrails: Benchmarking Contrail Detection on GOES-16 ABI

    Full text link
    Contrails (condensation trails) are line-shaped ice clouds caused by aircraft and are likely the largest contributor of aviation-induced climate change. Contrail avoidance is potentially an inexpensive way to significantly reduce the climate impact of aviation. An automated contrail detection system is an essential tool to develop and evaluate contrail avoidance systems. In this paper, we present a human-labeled dataset named OpenContrails to train and evaluate contrail detection models based on GOES-16 Advanced Baseline Imager (ABI) data. We propose and evaluate a contrail detection model that incorporates temporal context for improved detection accuracy. The human labeled dataset and the contrail detection outputs are publicly available on Google Cloud Storage at gs://goes_contrails_dataset

    The Effect of Compositional Context on Synthetic Gene Networks

    Get PDF
    It is well known that synthetic gene expression is highly sensitive to how genetic elements (promoter structure, spacing regions between promoter and coding sequences, ribosome binding sites, etc.) are spatially configured. An important topic that has received far less attention is how the compositional context, or spatial arrangement, of entire genes within a synthetic gene network affects their individual expression levels. In this paper we show, both quantitatively and qualitatively, that compositional context significantly alters transcription levels in synthetic gene networks. We demonstrate that key characteristics of gene induction, such as ultra-sensitivity and dynamic range, strongly depend on compositional context. We postulate that supercoiling can be used to explain this interference and validate this hypothesis through modeling and a series of in vitro supercoiling relaxation experiments. This compositional interference enables a novel form of feedback in synthetic gene networks. We illustrate the use of this feedback by redesigning the toggle switch to incorporate compositional context. We show the context-optimized toggle switch has improved threshold detection and memory properties

    An inkjet printed, roll-coated digital microfluidic device for inexpensive, miniaturized diagnostic assays

    Get PDF
    The diagnosis of infectious disease is typically carried out at the point-of-care (POC) using the lateral flow assay (LFA). While cost-effective and portable, LFAs often lack the clinical sensitivity and specificity required for accurate diagnoses. In response to this challenge, we introduce a new digital microfluidic (DMF) platform fabricated using a custom inkjet printing and roll-coating process that is scalable to mass production. The performance of the new devices is on par with that of traditional DMF devices fabricated in a cleanroom, with a materials cost for the new devices of only US $0.63 per device. To evaluate the usefulness of the new platform, we performed a 13-step rubella virus (RV) IgG immunoassay on the inkjet printed, roll-coated devices, which yielded a limit of detection of 0.02 IU mL^(−1), well below the diagnostic cut-off of 10 IU mL^(−1) for RV infection and immunity. We propose that this represents a breakthrough for DMF, lowering the costs to a level such that the new platforms will be an attractive alternative to LFAs for the diagnosis of infectious disease at the POC
    corecore