422 research outputs found

    XUV Opacity of Aluminum between the Cold-Solid to Warm-Plasma Transition

    Full text link
    We present calculations of the free-free XUV opacity of warm, solid-density aluminum at photon energies between the plasma frequency at 15 eV and the L-edge at 73 eV, using both density functional theory combined with molecular dynamics and a semi-analytical model in the RPA framework with the inclusion of local field corrections. As the temperature is increased from room temperature to 10 eV, with the ion and electron temperatures equal, we calculate an increase in the opacity in the range over which the degree of ionization is constant. The effect is less pronounced if only the electron temperature is allowed to increase. The physical significance of these increases is discussed in terms of intense XUV-laser matter interactions on both femtosecond and picosecond time-scales.Comment: 4 pages, 3 figure

    Leaf Eh and pH: A Novel Indicator of Plant Stress. Spatial, Temporal and Genotypic Variability in Rice (Oryza sativa L.)

    Get PDF
    A wealth of knowledge has been published in the last decade on redox regulations in plants. However, these works remained largely at cellular and organelle levels. Simple indicators of oxidative stress at the plant level are still missing. We developed a method for direct measurement of leaf Eh and pH, which revealed spatial, temporal, and genotypic variations in rice. Eh (redox potential) and Eh@pH7 (redox potential corrected to pH 7) of the last fully expanded leaf decreased after sunrise. Leaf Eh was high in the youngest leaf and in the oldest leaves, and minimum for the last fully expanded leaf. Leaf pH decreased from youngest to oldest leaves. The same gradients in Eh-pH were measured for various varieties, hydric conditions, and cropping seasons. Rice varieties differed in Eh, pH, and/or Eh@pH7. Leaf Eh increases and leaf pH decreases with plant age. These patterns and dynamics in leaf Eh-pH are in accordance with the pattern and dynamics of disease infections. Leaf Eh-pH can bring new insight on redox processes at plant level and is proposed as a novel indicator of plant stress/health. It could be used by agronomists, breeders, and pathologists to accelerate the development of crop cultivation methods leading to agroecological crop protection

    Frequency of silent brain infarction in transient global amnesia

    Get PDF
    Background: and purpose To determine the frequency and distribution pattern of acute DWI lesions outside the hippocampus in patients clinically presenting with Transient Global Amnesia (TGA). Methods: Consecutive patients clinically presenting with TGA between January 2010 and January 2017 admitted to our hospital were retrospectively evaluated. All patients fulfilled diagnostic criteria of TGA. We analyzed imaging and clinical data of all patients undergoing MRI with high-resolution diffusion-weighted imaging within 72 h from symptom onset. Results: A total of 126 cases were included into the study. Fifty-three percent (n = 71/126) presented with one or more acute lesions in hippocampal CA1-area. Additional acute DWI lesions in other cortical regions were found in 11% (n = 14/126). All patients with DWI lesions outside the hippocampus presented with neurological symptoms typical for TGA (without additional symptoms.) Conclusions: In a relevant proportion of clinical TGA patients, MRI reveals acute ischemic cerebral lesions. Therefore, cerebral MRI should be performed in patients with TGA to identify a possible cardiac involvement and to detect stroke chameleons

    Frequency of Hemorrhage on Follow Up Imaging in Stroke Patients Treated With rt-PA Depending on Clinical Course

    Get PDF
    Background: According to current guidelines, stroke patients treated with rt-PA should undergo brain imaging to exclude intracerebral bleeding 24 h after thrombolysis, before the start of medical secondary prevention. However, the usefulness of routine follow-up imaging with regard to changes in therapeutic management in patients without neurological deterioration is unclear. We hypothesized that follow up brain imaging solely to exclude bleeding in patients who clinically improved after rt-PA application may not be necessary. Methods: Retrospective single-center analysis including stroke patients treated with rt-PA. Records were reviewed for hemorrhagic transformation one day after systemic thrombolysis and brain imaging-based changes in therapeutic management. Twenty-four hour after thrombolysis patients were divided into four groups: (1) increased NIHSS score; (2) unchanged NIHSS score; (3) improved NIHSS score and; (4) NIHSS score = 0. Results: Out of 188 patients (mean age 73 years, 100 female) receiving rt-PA, 32 (17%) had imaging-proven hemorrhagic transformation including 11 (6%) patients with parenchymal hemorrhage. Patients in group (1, 2) more often had hypertension (p = 0.015) and more often had parenchymal hemorrhage (9 vs. 4%; p < 0.206) compared to group (3, 4) and imaging-based changes in therapeutic management were more frequent (19% vs. 6%; p = 0.007). Patients of group (3, 4) had no changes in therapeutic management in 94% of the cases. Patients in group (4) had no hemorrhagic transformation in routine follow-up brain imaging. Conclusions: Frequency of hemorrhagic transformation in Routine follow-up brain imaging and consecutive changes in therapeutic management were different depending on clinical course measured by NHISS score

    Frequency of Hemorrhage on Follow Up Imaging in Stroke Patients Treated With rt-PA Depending on Clinical Course

    Get PDF
    Background: According to current guidelines, stroke patients treated with rt-PA should undergo brain imaging to exclude intracerebral bleeding 24 h after thrombolysis, before the start of medical secondary prevention. However, the usefulness of routine follow-up imaging with regard to changes in therapeutic management in patients without neurological deterioration is unclear. We hypothesized that follow up brain imaging solely to exclude bleeding in patients who clinically improved after rt-PA application may not be necessary. Methods: Retrospective single-center analysis including stroke patients treated with rt-PA. Records were reviewed for hemorrhagic transformation one day after systemic thrombolysis and brain imaging-based changes in therapeutic management. Twenty-four hour after thrombolysis patients were divided into four groups: (1) increased NIHSS score; (2) unchanged NIHSS score; (3) improved NIHSS score and; (4) NIHSS score = 0. Results: Out of 188 patients (mean age 73 years, 100 female) receiving rt-PA, 32 (17%) had imaging-proven hemorrhagic transformation including 11 (6%) patients with parenchymal hemorrhage. Patients in group (1, 2) more often had hypertension (p = 0.015) and more often had parenchymal hemorrhage (9 vs. 4%; p < 0.206) compared to group (3, 4) and imaging-based changes in therapeutic management were more frequent (19% vs. 6%; p = 0.007). Patients of group (3, 4) had no changes in therapeutic management in 94% of the cases. Patients in group (4) had no hemorrhagic transformation in routine follow-up brain imaging. Conclusions: Frequency of hemorrhagic transformation in Routine follow-up brain imaging and consecutive changes in therapeutic management were different depending on clinical course measured by NHISS score

    Early recurrent ischemic lesions in patients with cryptogenic stroke and patent foramen ovale: an observational study

    Get PDF
    Background: Randomized controlled trials indicate that patent foramen ovate (PFO) closure reduces risk of stroke recurrence in patients with cryptogenic stroke and PFO. However, the optimal time point for PFO closure is unknown and depends on the risk of stroke recurrence. Objective: We aimed to investigate risk of early new ischemic lesions on cerebral magnetic resonance imaging (MRI) in cryptogenic stroke patients with and without PFO. Methods: Cryptogenic stroke patients underwent serial MRI examinations within 1 week after symptom onset to detect early new ischemic lesions. Diffusion-weighted imaging (DWI) lesions were delineated, co-registered, and analyzed visually for new hyperintensities by raters blinded to clinical details. A PFO was classified as stroke-related in patients with PFO and a Risk of Paradoxical Embolism (RoPE) score >5 points. Results: Out of 80 cryptogenic stroke patients, risk of early recurrent DWI lesions was not significantly different in cryptogenic stroke patients with and without PFO. Similar results were observed in patients <= 60 years of age. Patients with a stroke-related PFO even had a significantly lower risk of early recurrent ischemic lesions compared to all other patients with cryptogenic stroke (unadjusted odds ratio 0.23 [95% confidence interval 0.06-0.87], P = 0.030). Conclusion: Our data argue against a high risk of early stroke recurrence in patients with cryptogenic stroke and PFO

    Femtosecond Laser-Produced Plasma X-Rays from Periodically Modulated Surface Targets

    Get PDF
    We have studied theoretically and experimentally the x-ray production above 1 keV from femtosecond laser plasmas generated on periodically modulated surface targets. Laser energy coupling to plasma surface waves has been modeled using a numerical differential method. Almost total absorption of incident laser radiation is predicted for optimized interaction conditions. Silicon gratings have been irradiated by a 120fs Ti:sapphire laser at irradiances in excess of 1016 W/cm2. X-ray intensities above 1.5 keV (K-shell lines) have been measured as a function of the incidence angle. Results show a distinct x-ray emission maximum for the first order diffraction angle and are in good qualitative agreement with our theoretical predictions

    Synthesis and characterization of core-shell structure silica-coated Fe29.5Ni70.5 nanoparticles

    Full text link
    In view of potential applications of magnetic particles in biomedicine and electromagnetic devices, we made use of the classical Stober method base-catalysed hydrolysis and condensation of tetraethoxysilane (TEOS) to encapsulate FeNi nanoparticles within a silica shell. An original stirring system under high power ultrasounds made possible to disperse the otherwise agglomerated particles. Sonication guaranteed particles to remain dispersed during the Stober synthesis and also improved the efficiency of the method. The coated particles are characterized by electron microscopy (TEM) and spectroscopy (EDX) showing a core-shell structure with a uniform layer of silica. Silica-coating does not affect the core magnetic properties. Indeed, all samples are ferromagnetic at 77 K and room temperature and the Curie point remains unchanged. Only the coercive force shows an unexpected non-monotonous dependence on silica layer thickness.Comment: Regular paper submited to international peer-reveiwed journa

    Inflammatory Markers and Outcomes in Cardiovascular Disease

    Get PDF
    In a commentary on two new research studies in PLoS Medicine, Leonard Kritharides discusses the role of inflammatory markers in predicting cardiovascular outcomes and patients' responses to treatment

    Anomalous Self-Generated Electrostatic Fields in Nanosecond Laser-Plasma Interaction

    Full text link
    Electrostatic (E) fields associated with the interaction of a well-controlled, high-power, nanosecond laser pulse with an underdense plasma are diagnosed by proton radiography. Using a current 3D wave propagation code equipped with nonlinear and nonlocal hydrodynamics, we can model the measured E-fields that are driven by the laser ponderomotive force in the region where the laser undergoes filamentation. However, strong fields of up to 110 MV/m measured in the first millimeter of propagation cannot be reproduced in the simulations. This could point to the presence of unexpected strong thermal electron pressure gradients possibly linked to ion acoustic turbulence, thus emphasizing the need for the development of full kinetic collisional simulations in order to properly model laser-plasma interaction in these strongly nonlinear conditions.Comment: 12 pages, 4 figures, submitted to Physics of Plasma
    • …
    corecore