409 research outputs found

    Laser impulse coupling measurements at 400 fs and 80 ps using the LULI facility at 1057 nm wavelength

    Get PDF
    At the École Polytechnique « LULI » facility, we have measured the impulse coupling coefficient Cm (target momentum per joule of incident laser light) with several target materials in vacuum, at 1057 nm and 400 fs and 80 ps pulse duration. A total of 64 laser shots were completed in a two-week experimental campaign, divided between the two pulse durations and among the materials. Our main purpose was to resolve wide discrepancies among reported values for Cm in the 100 ps region, where many applications exist. A secondary purpose was to compare Cm at 400 fs and 80 ps pulse duration. The 80 ps pulse was obtained by partial compression. Materials were Al, Ta, W, Au, and POM (polyoxymethylene, trade name Delrin). One application of these results is to pulsed laser ablation propulsion in space, including space debris re-entry, where narrow ranges in Cm and specific impulse Isp spell the difference between dramatic and uneconomical performance. We had difficulty measuring mass loss from single shots. Imparted momentum in single laser shots was determined using pendulum deflection and photonic Doppler velocimetry. Cm was smaller at the 400 fs pulse duration than at 80 ps. To our surprise, Cm for Al at 80 ps was at most 30 N/MW with 30 kJ/m2 incident fluence. On the other extreme, polyoxymethylene (POM, trade name Delrin) demonstrated 770 N/MW under these conditions. Together, these results offer the possibility of designing a Cm value suited to an application, by mixing the materials appropriately

    Geometric Hyperplanes of the Near Hexagon L_3 times GQ(2, 2)

    Full text link
    Having in mind their potential quantum physical applications, we classify all geometric hyperplanes of the near hexagon that is a direct product of a line of size three and the generalized quadrangle of order two. There are eight different kinds of them, totalling to 1023 = 2^{10} - 1 = |PG(9, 2)|, and they form two distinct families intricately related with the points and lines of the Veldkamp space of the quadrangle in question.Comment: 10 pages, 5 figures and 2 tables; Version 2 - more detailed discussion of the properties of hyperplane

    Validation of Multiplex Serology detecting human herpesviruses 1-5

    Get PDF
    Human herpesviruses (HHV) cause a variety of clinically relevant conditions upon primary infection of typically young and immunocompetent hosts. Both primary infection and reactivation after latency can lead to more severe disease, such as encephalitis, congenital defects and cancer. Infections with HHV are also associated with cardiovascular and neuro-degenerative disease. However, most of the associations are based on retrospective case-control analyses and well-powered prospective cohort studies are needed for assessing temporality and causality. To enable comprehensive investigations of HHV-related disease etiology in large prospective population-based cohort studies, we developed HHV Multiplex Serology. This methodology represents a low-cost, high-throughput technology that allows simultaneous measurement of specific antibodies against five HHV species: Herpes simplex viruses 1 and 2, Varicella zoster virus, Epstein-Barr virus, and Cytomegalovirus. The newly developed HHV species-specific (‘Monoplex’) assays were validated against established gold-standard reference assays. The specificity and sensitivity of the HHV species-specific Monoplex Serology assays ranged from 92.3% to 100.0% (median 97.4%) and 91.8% to 98.7% (median 96.6%), respectively. Concordance with reference assays was very high with kappa values ranging from 0.86 to 0.96 (median kappa 0.93). Multiplexing the Monoplex Serology assays resulted in no loss of performance and allows simultaneous detection of antibodies against the 5 HHV species in a high-throughput manner

    Parity nonconserving cold neutron-parahydrogen interactions

    Full text link
    Three pion dominated observables of the parity nonconserving interactions between the cold neutrons and parahydrogen are calculated. The transversely polarized neutron spin rotation, unpolarized neutron longitudinal polarization, and photon-asymmetry of the radiative polarized neutron capture are considered. For the numerical evaluation of the observables, the strong interactions are taken into account by the Reid93 potential and the parity nonconserving interactions by the DDH model along with the two-pion exchange.Comment: 17 pages, 2 figure

    Transfers from Earth to LEO and LEO to interplanetary space using lasers

    Get PDF
    New data on some materials at 80ps pulse duration and 1057 nm wavelength give us the option of proportionally combining them to obtain arbitrary values between 35 (aluminum) and 800 N/MW (POM, polyoxymethylene) for momentum coupling coefficient Cm. Laser ablation physics lets us transfer to LEO from Earth, or to interplanetary space using repetitively pulsed lasers and Cm values appropriate for each mission. We discuss practical results for lifting small payloads from Earth to LEO, and space missions such as a cis-Mars orbit with associated laser system parameters

    Reflections

    Get PDF
    The American Society of International Law Committee recommended that the Manley 0. Hudson Medal be awarded to Professor Eric Stein for his lifetime of significant contributions to international and comparative law. Stein, the Hessel E. Yntema Professor of Law, Emeritus, at the University of Michigan Law School, had been an active supporter of ASIL as Honorary Vice President, Counsellor, and Honorary Editor of, and frequent contributor to, the American Journal of International Law. His many books and articles established him as a leading thinker and writer on European Community law and on what he described in a famous article as the Uses, Misuses, and Nonuses of Comparative Law

    Search for the glueball candidates f0(1500) and fJ(1710) in gamma gamma collisions

    Full text link
    Data taken with the ALEPH detector at LEP1 have been used to search for gamma gamma production of the glueball candidates f0(1500) and fJ(1710) via their decay to pi+pi-. No signal is observed and upper limits to the product of gamma gamma width and pi+pi- branching ratio of the f0(1500) and the fJ(1710) have been measured to be Gamma_(gamma gamma -> f0(1500)). BR(f0(1500)->pi+pi-) < 0.31 keV and Gamma_(gamma gamma -> fJ(1710)). BR(fJ(1710)->pi+pi-) < 0.55 keV at 95% confidence level.Comment: 10 pages, 3 figure
    corecore