4,128 research outputs found

    Effects of wind on turbofan engines in outdoor static test stands

    Get PDF
    Wind can affect measured thrust and can cause turbofan engine speed to fluctuate during outdoor testing. Techniques used at an outdoor test stand at NASA Lewis Research Center to make testing easier and faster and to improve data repeatability include using an inflow control device (ICD) to make fan speed steadier, taking many raw data samples for better averaging, and correcting thrust for wind direction and speed. Data from engine tests are presented to show that the techniques improve repeatability of thrust and airflow measurements under various wind conditions

    Static and transient performance of YF-102 engine with up to 14 percent core airbleed for the quiet short-haul research aircraft

    Get PDF
    An outdoor static test stand was used to measure the steady-state and transient performance of the YF-102 turbofan engine with core airbleed. The test configuration included a bellmouth inlet and a confluent-flow exhaust system similar in size to the quiet short-haul research aircraft (QSRA) exhaust system. For the steady-state tests, the engine operated satisfactorily with core bleed up to 14 percent of the core inlet flow. For the transient tests the engine accelerated and decelerated satisfactorily with no core bleed and with core bleed up to 11 percent of the core inlet flow (maximum tested). For some of the tests the core-bleed flow rate was scheduled to vary with fan discharge pressure, to simulate the QSRA bleed requirements. No stability, surge, stall, overtemperature, combustor flameout, or other operating problems were encountered in any of the tests. Steady-state and transient engine performance data are presented in graphs, and fuel-control trajectories for typical transient tests are shown

    Internal reversing flow in a tailpipe offtake configuration for SSTOVL aircraft

    Get PDF
    A generic one-third scale model of a tailpipe offtake system for a supersonic short takeoff vertical landing (SSTOVL) aircraft was tested at LeRC Powered Lift Facility. The model consisted of a tailpipe with twin elbows, offtake ducts, and flow control nozzles, plus a small ventral nozzle and a blind flange to simulate a blocked cruise nozzle. The offtake flow turned through a total angle of 177 degrees relative to the tailpipe inlet axis. The flow split was 45 percent to each offtake and 10 percent to the ventral nozzle. The main test objective was to collect data for comparison to the performance of the same configuration predicted by a computational fluid dynamics (CFD) analysis. Only the experimental results are given - the analytical results are published in a separate paper. Performance tests were made with unheated air at tailpipe-to-ambient pressure ratios up to 5. The total pressure loss through the offtakes was as high as 15.5 percent. All test results are shown as graphs, contour plots, and wall pressure distributions. The complex flow patterns in the tailpipe and elbows at the offtake openings are described with traversing flow angle probe and paint streak flow visualization data

    Are there functional consequences of a reduction in selenium intake in UK subjects?

    Get PDF
    Dietary Se levels in the UK have fallen over the last 20 years and recent surveys indicate that average Se intakes are 30-40 microg/d, which is well below the current UK reference nutrient intake for adult men (75 microg/d) or women (60 microg/d). Functional consequences of this decline have not been recognised, although epidemiological data suggest it may contribute to increased risk of infections and incidence of some cancers. Previous data have indicated that biochemical changes in Se-dependent proteins occur in otherwise healthy UK subjects given small Se supplements. The current studies have focused on the effect of small Se supplements on the immune response since there is evidence of specific interactions between Se intake and viral replication, and since the potential anti-cancer effects of Se may be mediated by non-antioxidant effects of Se such as changes in immune function. Data indicate that subjects given small Se supplements (50 or 100 microg Se/d) have changes in the activity of Se-dependent enzymes and evidence of improved immune function and clearance of an administered live attenuated virus in the form of poliovirus vaccine. Responses of individual subjects to Se supplements are variable, and current work is evaluating potential explanations for this variability, including genetic variability and pre-existing Se status

    Core noise measurements on a YF-102 turbofan engine

    Get PDF
    Core noise from a YF-102 high bypass ratio turbofan engine was investigated through the use of simultaneous measurements of internal fluctuating pressures and far field noise. Acoustic waveguide probes, located in the engine at the compressor exit, in the combustor, at the turbine exit, and in the core nozzle, were employed to measure internal fluctuating pressures. Spectra showed that the internal signals were free of tones, except at high frequency where machinery noise was present. Data obtained over a wide range of engine conditions suggest that below 60% of maximum fan speed the low frequency core noise contributes significantly to the far field noise

    Opportunistic detection of atrial fibrillation using blood pressure monitors: a systematic review

    Get PDF
    Background: Atrial Fibrillation (AF) affects around 2% of the population and early detection is beneficial, allowing patients to begin potentially life-saving anticoagulant therapies. Blood pressure (BP) monitors may offer an opportunity to screen for AF. Aim: To identify and appraise studies which report the diagnostic accuracy of automated BP monitors used for opportunistic AF detection. Methods: A systematic search was performed of the Medline, Medline-in-process and Embase literature databases. Papers were eligible if they described primary studies of the evaluation of a BP device for AF detection, were published in a peer reviewed journal and reported values for the sensitivity and specificity. Included studies were appraised using the QUADAS-2 tool to assess their risk of bias and applicability to opportunistic AF detection. Values for the sensitivity and specificity of AF detection were extracted from each paper and compared. Results and Conclusion: We identified seven papers evaluating six devices from two manufacturers. Only one study scored low risk in all of the QUADAS-2 domains. All studies reported specificity greater than 85% and six reported sensitivity greater than 90%. The studies showed that blood pressure devices with embedded algorithms for detecting arrhythmias show promise as screening tools for AF, comparing favourably with manual pulse palpation. But the studies used different methodologies and many were subject to potential bias. More studies are needed to more precisely define the sensitivity and specificity of opportunistic screening for AF during blood pressure measurement before its clinical utility in the population of interest can be assessed fully

    Accuracy of pulse interval timing in ambulatory blood pressure measurement

    Get PDF
    Blood pressure (BP) monitors rely on pulse detection. Some blood pressure monitors use pulse timings to analyse pulse interval variability for arrhythmia screening, but this assumes that the pulse interval timings detected from BP cuffs are accurate compared with RR intervals derived from ECG. In this study we compared the accuracy of pulse intervals detected using an ambulatory blood pressure monitor (ABPM) with single lead ECG. Twenty participants wore an ABPM for three hours and a data logger which synchronously measured cuff pressure and ECG. RR intervals were compared with corresponding intervals derived from the cuff pressure tracings using three different pulse landmarks. Linear mixed effects models were used to assess differences between ECG and cuff pressure timings and to investigate the effect of potential covariates. In addition, the maximum number of successive oscillometric beats detectable in a measurement was assessed. From 243 BP measurements, the foot landmark of the oscillometric pulse was found to be associated with fewest covariates and had a random error of 9.5 ms. 99% of the cuff pressure recordings had more than 10 successive detectable oscillometric beats. RR intervals can be accurately estimated using an ABPM

    Academic Research and Reform: A History of the Empirical Basis for NCAA Academic Policy

    Get PDF
    The purpose of this article is to provide an historical overview of the National Collegiate Athletic Association’s (NCAA) academic reform, with a particular focus on the empirical basis for the decisions made. The authors outline four eras of academic reform, examine the types of information the NCAA has collected and used to make decisions about academic policy, and explore the limits of such academic data
    • …
    corecore