    Long-term outcomes after stenting versus endarterectomy for treatment of symptomatic carotid stenosis: the International Carotid Stenting Study (ICSS) randomised trial.

    Get PDF
    BACKGROUND: Stenting is an alternative to endarterectomy for treatment of carotid artery stenosis, but long-term efficacy is uncertain. We report long-term data from the randomised International Carotid Stenting Study comparison of these treatments. METHODS: Patients with symptomatic carotid stenosis were randomly assigned 1:1 to open treatment with stenting or endarterectomy at 50 centres worldwide. Randomisation was computer generated centrally and allocated by telephone call or fax. Major outcomes were assessed by an independent endpoint committee unaware of treatment assignment. The primary endpoint was fatal or disabling stroke in any territory after randomisation to the end of follow-up. Analysis was by intention to treat ([ITT] all patients) and per protocol from 31 days after treatment (all patients in whom assigned treatment was completed). Functional ability was rated with the modified Rankin scale. This study is registered, number ISRCTN25337470. FINDINGS: 1713 patients were assigned to stenting (n=855) or endarterectomy (n=858) and followed up for a median of 4·2 years (IQR 3·0-5·2, maximum 10·0). Three patients withdrew immediately and, therefore, the ITT population comprised 1710 patients. The number of fatal or disabling strokes (52 vs 49) and cumulative 5-year risk did not differ significantly between the stenting and endarterectomy groups (6·4% vs 6·5%; hazard ratio [HR] 1·06, 95% CI 0·72-1·57, p=0·77). Any stroke was more frequent in the stenting group than in the endarterectomy group (119 vs 72 events; ITT population, 5-year cumulative risk 15·2% vs 9·4%, HR 1·71, 95% CI 1·28-2·30, p<0·001; per-protocol population, 5-year cumulative risk 8·9% vs 5·8%, 1·53, 1·02-2·31, p=0·04), but were mainly non-disabling strokes. The distribution of modified Rankin scale scores at 1 year, 5 years, or final follow-up did not differ significantly between treatment groups. INTERPRETATION: Long-term functional outcome and risk of fatal or disabling stroke are similar for stenting and endarterectomy for symptomatic carotid stenosis. FUNDING: Medical Research Council, Stroke Association, Sanofi-Synthélabo, European Union

    Length of carotid stenosis predicts peri-procedural stroke or death and restenosis in patients randomized to endovascular treatment or endarterectomy.

    Get PDF
    BACKGROUND: The anatomy of carotid stenosis may influence the outcome of endovascular treatment or carotid endarterectomy. Whether anatomy favors one treatment over the other in terms of safety or efficacy has not been investigated in randomized trials. METHODS: In 414 patients with mostly symptomatic carotid stenosis randomized to endovascular treatment (angioplasty or stenting; n = 213) or carotid endarterectomy (n = 211) in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS), the degree and length of stenosis and plaque surface irregularity were assessed on baseline intraarterial angiography. Outcome measures were stroke or death occurring between randomization and 30 days after treatment, and ipsilateral stroke and restenosis ≥50% during follow-up. RESULTS: Carotid stenosis longer than 0.65 times the common carotid artery diameter was associated with increased risk of peri-procedural stroke or death after both endovascular treatment [odds ratio 2.79 (1.17-6.65), P = 0.02] and carotid endarterectomy [2.43 (1.03-5.73), P = 0.04], and with increased long-term risk of restenosis in endovascular treatment [hazard ratio 1.68 (1.12-2.53), P = 0.01]. The excess in restenosis after endovascular treatment compared with carotid endarterectomy was significantly greater in patients with long stenosis than with short stenosis at baseline (interaction P = 0.003). Results remained significant after multivariate adjustment. No associations were found for degree of stenosis and plaque surface. CONCLUSIONS: Increasing stenosis length is an independent risk factor for peri-procedural stroke or death in endovascular treatment and carotid endarterectomy, without favoring one treatment over the other. However, the excess restenosis rate after endovascular treatment compared with carotid endarterectomy increases with longer stenosis at baseline. Stenosis length merits further investigation in carotid revascularisation trials

    Factors associated with time delay to carotid stenting in patients with a symptomatic carotid artery stenosis

    Get PDF
    Treatment of a symptomatic stenosis is known to be most beneficial within 14 days after the presenting event but this can frequently not be achieved in daily practice. The aim of this study was the assessment of factors responsible for this time delay to treatment. A retrospective analysis of a prospective two-center CAS database was carried out to investigate the potential factors that influence a delayed CAS treatment. Of 374 patients with a symptomatic carotid stenosis, 59.1% were treated beyond ≥14 days. A retinal TIA event (OR = 3.59, 95% CI 1.47–8.74, p < 0.01) was found to be a predictor for a delayed treatment, whereas the year of the intervention (OR = 0.32, 95% CI 0.20–0.50, p < 0.01) and a contralateral carotid occlusion (OR = 0.42, 95% CI 0.21–0.86, p = 0.02) were predictive of an early treatment. Similarly, within the subgroup of patients with transient symptoms, the year of the intervention (OR = 0.28, 95% CI 0.14–0.59, p < 0.01) was associated with an early treatment, whereas a retinal TIA as the qualifying event (OR = 6.96, 95% CI 2.37–20.47, p < 0.01) was associated with a delayed treatment. Treatment delay was most pronounced in patients with an amaurosis fugax, whereas a contralateral carotid occlusion led to an early intervention. Although CAS is increasingly performed faster in the last years, there is still scope for an even more accelerated treatment strategy, which might prevent future recurrent strokes prior to treatment

    Inflammation and In-Stent Restenosis: The Role of Serum Markers and Stent Characteristics in Carotid Artery Stenting

    Get PDF
    BACKGROUND: Carotid angioplasty and stenting (CAS) may currently be recommended especially in younger patients with a high-grade carotid artery stenosis. However, evidence is accumulating that in-stent restenosis (ISR) could be an important factor endangering the long-term efficacy of CAS. The aim of this study was to investigate the influence of inflammatory serum markers and procedure-related factors on ISR as diagnosed with duplex sonography. METHODS: We analyzed 210 CAS procedures in 194 patients which were done at a single university hospital between May 2003 and June 2010. Periprocedural C-reactive protein (CRP) and leukocyte count as well as stent design and geometry, and other periprocedural factors were analyzed with respect to the occurrence of an ISR as diagnosed with serial carotid duplex ultrasound investigations during clinical long-term follow-up. RESULTS: Over a median of 33.4 months follow-up (IQR: 14.9-53.7) of 210 procedures (mean age of 67.9±9.7 years, 71.9% male, 71.0% symptomatic) an ISR of ≥70% was detected in 5.7% after a median of 8.6 months (IQR: 3.4-17.3). After multiple regression analysis, leukocyte count after CAS-intervention (odds ratio (OR): 1.31, 95% confidence interval (CI): 1.02-1.69; p = 0.036), as well as stent length and width were associated with the development of an ISR during follow-up (OR: 1.25, 95% CI: 1.05-1.65, p = 0.022 and OR: 0.28, 95% CI: 0.09-0.84, p = 0.010). CONCLUSIONS: The majority of ISR during long-term follow-up after CAS occur within the first year. ISR is associated with periinterventional inflammation markers and influenced by certain stent characteristics such as stent length and width. Our findings support the assumption that stent geometry leading to vessel injury as well as periprocedural inflammation during CAS plays a pivotal role in the development of carotid artery ISR

    Carotid endarterectomy and carotid artery stenting utilization trends over time

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Carotid endarterectomy (CEA) has been the standard in atherosclerotic stroke prevention for over 2 decades. More recently, carotid artery stenting (CAS) has emerged as a less invasive alternative for revascularization. The purpose of this study was to investigate whether an increase in stenting parallels a decrease in endarterectomy, if there are specific patient factors that influence one intervention over the other, and how these factors may have changed over time.</p> <p>Methods</p> <p>Using a nationally representative sample of US hospital discharge records, data on CEA and CAS procedures performed from 1998 to 2008 were obtained. In total, 253,651 cases of CEA and CAS were investigated for trends in utilization over time. The specific data elements of age, gender, payer source, and race were analyzed for change over the study period, and their association with type of intervention was examined by multiple logistic regression analysis.</p> <p>Results</p> <p>Rates of intervention decreased from 1998 to 2008 (P < 0.0001). Throughout the study period, endarterectomy was the much more widely employed procedure. Its use displayed a significant downward trend (P < 0.0001), with the lowest rates of intervention occurring in 2007. In contrast, carotid artery stenting displayed a significant increase in use over the study period (P < 0.0001), with the highest intervention rates occurring in 2006. Among the specific patient factors analyzed that may have altered utilization of CEA and CAS over time, the proportion of white patients who received intervention decreased significantly (P < 0.0001). In multivariate modeling, increased age, male gender, white race, and earlier in the study period were significant positive predictors of CEA use.</p> <p>Conclusions</p> <p>Rates of carotid revascularization have decreased over time, although this has been the result of a reduction in CEA despite an overall increase in CAS. Among the specific patient factors analyzed, age, gender, race, and time were significantly associated with the utilization of these two interventions.</p

    Biosensors for Brain Trauma and Dual Laser Doppler Flowmetry: Enoxaparin Simultaneously Reduces Stroke-Induced Dopamine and Blood Flow while Enhancing Serotonin and Blood Flow in Motor Neurons of Brain, In Vivo

    Get PDF
    Neuromolecular Imaging (NMI) based on adsorptive electrochemistry, combined with Dual Laser Doppler Flowmetry (LDF) is presented herein to investigate the brain neurochemistry affected by enoxaparin (Lovenox®), an antiplatelet/antithrombotic medication for stroke victims. NMI with miniature biosensors enables neurotransmitter and neuropeptide (NT) imaging; each NT is imaged with a response time in milliseconds. A semiderivative electronic reduction circuit images several NT’s selectively and separately within a response time of minutes. Spatial resolution of NMI biosensors is in the range of nanomicrons and electrochemically-induced current ranges are in pico- and nano-amperes. Simultaneously with NMI, the LDF technology presented herein operates on line by illuminating the living brain, in this example, in dorso-striatal neuroanatomic substrates via a laser sensor with low power laser light containing optical fiber light guides. NMI biotechnology with BRODERICK PROBE® biosensors has a distinct advantage over conventional electrochemical methodologies both in novelty of biosensor formulations and on-line imaging capabilities in the biosensor field. NMI with unique biocompatible biosensors precisely images NT in the body, blood and brain of animals and humans using characteristic experimentally derived half-wave potentials driven by oxidative electron transfer. Enoxaparin is a first line clinical treatment prescribed to halt the progression of acute ischemic stroke (AIS). In the present studies, BRODERICK PROBE® laurate biosensors and LDF laser sensors are placed in dorsal striatum (DStr) dopaminergic motor neurons in basal ganglia of brain in living animals; basal ganglia influence movement disorders such as those correlated with AIS. The purpose of these studies is to understand what is happening in brain neurochemistry and cerebral blood perfusion after causal AIS by middle cerebral artery occlusion in vivo as well as to understand consequent enoxaparin and reperfusion effects actually while enoxaparin is inhibiting blood clots to alleviate AIS symptomatology. This research is directly correlated with the medical and clinical needs of stroke victims. The data are clinically relevant, not only to movement dysfunction but also to the depressive mood that stroke patients often endure. These are the first studies to image brain neurotransmitters while any stroke medications, such as anti-platelet/anti-thrombotic and/or anti-glycoprotein are working in organ systems to alleviate the debilitating consequences of brain trauma and stroke/brain attacks

    Impact of Carotid Artery Stenosis on Quality of Life: A Systematic Review

    Get PDF
    © 2018, Springer Nature Switzerland AG. Objectives: The aim of this study was to identify themes that determine health-related quality of life (HRQoL) in patients with carotid artery stenosis and identify the patient-reported outcome measures (PROMs) that best cover the identified themes. Methods: A systematic review of the main six databases from inception to September 2018 was undertaken to identify primary qualitative studies reporting on the HRQoL of patients with carotid artery stenosis. The quality of studies was assessed using the Critical Appraisal Skills Programme (CASP) criteria. Findings from the included studies were analysed using framework analysis methodology. The identified themes were mapped against the items/domains from the PROMs used previously in patients with carotid artery stenosis. Results: The systematic review identified four papers that fulfilled the inclusion criteria. The included papers reported the views of 62 patients with symptomatic carotid artery stenosis; 24 of the patients were awaiting assessment for intervention, 26 had carotid endarterectomy, and 12 were turned down for intervention and received best medical therapy. The overall quality of the included studies was good based on CASP criteria. Framework analysis identified 16 themes that were divided into five main domains: anxiety, impact on personal roles and activities, effect on independence, psychological impact, and symptoms. The best-fit generic and disease-specific PROMs were the Medical Outcomes Study 36-Item Short Form (SF-36®) and the Carotid Stenosis Specific Outcome Measure (CSSOM), respectively. None of the PROMs covered all the themes identified in the qualitative systematic review. Conclusion: The findings from the review identified the important themes that affect patients with carotid stenosis disease. The current generic and disease-specific PROMs do not cover all themes that impact the HRQoL of patients suffering with this disease. The proposed themes can be used to develop a new disease-specific PROM to measure HRQoL

    Testing devices for the prevention and treatment of stroke and its complications

    Get PDF
    We are entering a challenging but exciting period when many new interventions may appear for stroke based on the use of devices. Hopefully these will lead to improved outcomes at a cost that can be afforded in most parts of the world. Nevertheless, it is vital that lessons are learnt from failures in the development of pharmacological interventions (and from some early device studies), including inadequate preclinical testing, suboptimal trial design and analysis, and underpowered studies. The device industry is far more disparate than that seen for pharmaceuticals; companies are very variable in size and experience in stroke, and are developing interventions across a wide range of stroke treatment and prevention. It is vital that companies work together where sales and marketing are not involved, including in understanding basic stroke mechanisms, prospective systematic reviews, and education of physicians. Where possible, industry and academics should also work closely together to ensure trials are designed to be relevant to patient care and outcomes. Additionally, regulation of the device industry lags behind that for pharmaceuticals, and it is critical that new interventions are shown to be safe and effective rather than just feasible. Phase IV postmarketing surveillance studies will also be needed to ensure that devices are safe when used in the ‘real-world’ and to pick up uncommon adverse events

    Carotid artery disease in older people: clinical features and management

    No full text