2,736 research outputs found

    Escherichia coli contamination and health aspects of soil and tomatoes (Solanum lycopersicum L.) subsurface drip irrigated with on-site treated domestic wastewater.

    No full text
    Faecal contamination of soil and tomatoes irrigated by sprinkler as well as surface and subsurface drip irrigation with treated domestic wastewater were compared in 2007 and 2008 at experimental sites in Crete and Italy. Wastewater was treated by Membrane Bio Reactor (MBR) technology, gravel filtration or UV-treatment before used for irrigation. Irrigation water, soil and tomato samples were collected during two cropping seasons and enumerated for the faecal indicator bacterium Escherichia coli and helminth eggs. The study found elevated levels of E. coli in irrigation water (mean: Italy 1753 cell forming unit (cfu) per 100 ml and Crete 488 cfu per 100 ml) and low concentrations of E. coli in soil (mean: Italy 95 cfu g(-1) and Crete 33 cfu g(-1)). Only two out of 84 tomato samples in Crete contained E. coli (mean: 2700 cfu g(-1)) while tomatoes from Italy were free of E. coli. No helminth eggs were found in the irrigation water or on the tomatoes from Crete. Two tomato samples out of 36 from Italy were contaminated by helminth eggs (mean: 0.18 eggs g(-1)) and had been irrigated with treated wastewater and tap water, respectively. Pulsed Field Gel Electrophoresis DNA fingerprints of E. coli collected during 2008 showed no identical pattern between water and soil isolates which indicates contribution from other environmental sources with E. coli, e.g. wildlife. A quantitative microbial risk assessment (QMRA) model with Monte Carlo simulations adopted by the World Health Organization (WHO) found the use of tap water and treated wastewater to be associated with risks that exceed permissible limits as proposed by the WHO (1.0 × 10(-3) disease risk per person per year) for the accidental ingestion of irrigated soil by farmers (Crete: 0.67 pppy and Italy: 1.0 pppy). The QMRA found that the consumption of tomatoes in Italy was deemed to be safe while permissible limits were exceeded in Crete (1.0 pppy). Overall the quality of tomatoes was safe for human consumption since the disease risk found on Crete was based on only two contaminated tomato samples. It is a fundamental limitation of the WHO QMRA model that it is not based on actual pathogen numbers, but rather on numbers of E. coli converted to estimated pathogen numbers, since it is widely accepted that there is poor correlation between E. coli and viral and parasite pathogens. Our findings also stress the importance of the external environment, typically wildlife, as sources of faecal contamination

    Design considerations for a new generation of SiPMs with unprecedented timing resolution

    Full text link
    The potential of photon detectors to achieve precise timing information is of increasing importance in many domains, PET and CT scanners in medical imaging and particle physics detectors, amongst others. The goal to increase by an order of magnitude the sensitivity of PET scanners and to deliver, via time-of-flight (TOF), true space points for each event, as well as the constraints set by future particle accelerators require a further leap in time resolution of scintillator-based ionizing radiation detectors, reaching eventually a few picoseconds resolution for sub MeV energy deposits. In spite of the impressive progress made in the last decade by several manufacturers, the Single Photon Time Resolution (SPTR) of SiPMs is still in the range of 70-120ps FWHM, whereas a value of 10ps or even less would be desirable. Such a step requires a break with traditional methods and the development of novel technologies. The possibility of combining the extraordinary potential of nanophotonics with new approaches offered by modern microelectronics and 3D electronic integration opens novel perspectives for the development of a new generation of metamaterial-based SiPMs with unprecedented photodetection efficiency and timing resolution.Comment: 16 pages, 6 figures, submitted to JINS

    Communication, digital media and future: new scenarios and future changes

    Get PDF
    Proceedings of the MEDCOM 2020+1 International Conferenc

    SiPM and front-end electronics development for Cherenkov light detection

    Full text link
    The Italian Institute of Nuclear Physics (INFN) is involved in the development of a demonstrator for a SiPM-based camera for the Cherenkov Telescope Array (CTA) experiment, with a pixel size of 6Ă—\times6 mm2^2. The camera houses about two thousands electronics channels and is both light and compact. In this framework, a R&D program for the development of SiPMs suitable for Cherenkov light detection (so called NUV SiPMs) is ongoing. Different photosensors have been produced at Fondazione Bruno Kessler (FBK), with different micro-cell dimensions and fill factors, in different geometrical arrangements. At the same time, INFN is developing front-end electronics based on the waveform sampling technique optimized for the new NUV SiPM. Measurements on 1Ă—\times1 mm2^2, 3Ă—\times3 mm2^2, and 6Ă—\times6 mm2^2 NUV SiPMs coupled to the front-end electronics are presentedComment: In Proceedings of the 34th International Cosmic Ray Conference (ICRC2015), The Hague, The Netherlands. All CTA contributions at arXiv:1508.0589

    Scratching Cu|Au nanolaminates

    Get PDF
    We used molecular dynamics simulations to study the scratching of CujAu nanolaminates of 5 nm layer thickness with a nanoscale indenter of 15 nm radius at normal forces between 0.5 µN and 2 µN. Our simulations show that Au layers wear quickly while Cu layers are more resistant to wear. Plowing was accompanied by the roughening of the Cu|Au heterointerface that lead to the folding of the nanolaminate structure at the edge of the wear track. Our explorative simulations hint at the complex deformation processes occurring in nanolaminates under tribological load

    The prediction of blood–tissue partitions, water–skin partitions and skin permeation for agrochemicals

    Get PDF
    YesBACKGROUND: There is considerable interest in the blood–tissue distribution of agrochemicals, and a number of researchershave developed experimental methods for in vitro distribution. These methods involve the determination of saline–blood andsaline–tissue partitions; not only are they indirect, but they do not yield the required in vivo distribution.RESULTS: The authors set out equations for gas–tissue and blood–tissue distribution, for partition from water into skin andfor permeation from water through human skin. Together with Abraham descriptors for the agrochemicals, these equationscan be used to predict values for all of these processes. The present predictions compare favourably with experimental in vivoblood–tissue distribution where available. The predictions require no more than simple arithmetic.CONCLUSIONS: The present method represents a much easier and much more economic way of estimating blood–tissuepartitions than the method that uses saline–blood and saline–tissue partitions. It has the added advantages of yielding therequired in vivo partitions and being easily extended to the prediction of partition of agrochemicals from water into skin andpermeation from water through skin

    NUV-HD SiPMs with metal-filled trenches

    Get PDF
    In this paper we present the performance of a new SiPM that is sensitive to blue light and features narrow metal-filled trenches placed in the area around the single-photon avalanche diodes (SPADs) that allow an almost complete suppression the internal optical crosstalk. In particular, we show the benefits of this technological upgrade in terms of electro-optical SiPM performance when compared to the previous technology which had only a partial optical screening between the SPADs. The most relevant effect is the much higher bias voltage that can be applied to the new device before the noise diverges. This allows to optimize and improve both the photon detection efficiency and the single-photon time resolution. We also coupled the SiPMs to LYSO scintillators to verify the performance for possible application in Positron-Emission Tomography. Thanks to the better electro-optical features we were able to measure an improved coincidence time resolution. Furthermore, the optimal voltage operation region is substantially larger, making this SiPM more suitable for real system application where thousands of channels have to provide stable and reproducible performance
    • …
    corecore