425 research outputs found

    Near-field terahertz imaging using sub-wavelength apertures without cutoff

    Get PDF
    We demonstrate near-field imaging capabilities of a conical waveguide without cutoff using broadband terahertz (THz) radiation. In contrast to conventional conically tapered waveguides, which are characterized by strong suppression of transmission below the cutoff frequency, the proposed structure consists of two pieces, such that there is an adjustable gap along the length of the waveguide. We also ensure that the sidewalls are thin in the vicinity of the gap. The combination of these geometrical features allow for significantly enhanced transmission at frequencies below the cutoff frequency, without compromising the mode confinement and, consequently, the spatial resolution when used for imaging applications. We demonstrate near-field imaging with this probe simultaneously at several frequencies, corresponding to three regimes: above, near and below the cutoff frequency. We observe only mild degradation in the image quality as the frequency is reduced below the cutoff frequency. These results suggest that further refinements in the probe structure will allow for improved imaging capabilities at frequencies well below the cutoff frequency

    Distributed Cyber-Attack Detection in the Secondary Control of DC Microgrids

    Get PDF
    The paper considers the problem of detecting cyber-attacks occurring in communication networks typically used in the secondary control layer of DC microgrids. The proposed distributed methodology allows for scalable monitoring of a microgrid and is able to detect the presence of data injection attacks in the communications among Distributed Generation Units (DGUs) - governed by consensus-based control - and isolate the communication link over which the attack is injected. Each local attack detector requires limited knowledge regarding the dynamics of its neighbors. Detectability properties of the method are analyzed, as well as a class of undetectable attacks. Some results from numerical simulation are presented to demonstrate the effectiveness of the proposed approach

    SPREAD 4:Online visualisation of pathogen phylogeographic reconstructions

    Get PDF
    Phylogeographic analyses aim to extract information about pathogen spread from genomic data, and visualising spatio-temporal reconstructions is a key aspect of this process. Here we present SPREAD 4, a feature-rich web-based application that visualises estimates of pathogen dispersal resulting from Bayesian phylogeographic inference using BEAST on a geographic map, offering zoom-and-filter functionality and smooth animation over time. SPREAD 4 takes as input phylogenies with both discrete and continuous location annotation and offers customised visualisation as well as generation of publication-ready figures. SPREAD 4 now features account-based storage and easy sharing of visualisations by means of unique web addresses. SPREAD 4 is intuitive to use and is available online at https://spreadviz.org, with an accompanying web page containing answers to frequently asked questions at https://beast.community/spread4

    Terahertz imaging and spectroscopy of large-area single-layer graphene

    Full text link
    We demonstrate terahertz (THz) imaging and spectroscopy of a 15x15-mm^2 single-layer graphene film on Si using broadband THz pulses. The THz images clearly map out the THz carrier dynamics of the graphene-on-Si sample, allowing us to measure sheet conductivity with sub-mm resolution without fabricating electrodes. The THz carrier dynamics are dominated by intraband transitions and the THz-induced electron motion is characterized by a flat spectral response. A theoretical analysis based on the Fresnel coefficients for a metallic thin film shows that the local sheet conductivity varies across the sample from {\sigma}s = 1.7x10^-3 to 2.4x10^-3 {\Omega}^-1 (sheet resistance, {\rho}s = 420 - 590 {\Omega}/sq).Comment: 6 pages, 5 figure

    Manipulation of drugs to achieve the required dose is intrinsic to paediatric practice but is not supported by guidelines or evidence

    Get PDF
    Background: A lack of age-appropriate formulations can make it difficult to administer medicines to children. A manipulation of the dosage form may be required to achieve the required dose. This study aimed to describe medicines that are manipulated to achieve the required dose in paediatric practice.Method: A structured, undisguised observational study and postal survey. The observational study investigated drug manipulations occurring in clinical practice across three sites. The questionnaire, administered to a sample of paediatric nurses throughout the UK, surveyed manipulations conducted and nurses' experiences and views.Results: The observational study identified 310 manipulations, of which 62% involved tablets, 21% were intravenous drugs and 10% were sachets. Of the 54 observed manipulations 40 involved tablets with 65% of the tablets being cut and 30% dispersed to obtain a smaller dose. 188 manipulations were reported by questionnaire respondents, of these 46% involved tablets, 12% were intravenous drugs, and 12% were nebuliser solutions. Manipulations were predominantly, but not exclusively, identified in specialist clinical areas with more highly dependent patients. Questionnaire respondents were concerned about the accuracy of the dose achieved following manipulations and the lack of practice guidance.Conclusion: Manipulations to achieve the required dose occur throughout paediatric in-patient settings. The impact of manipulations on the efficacy of the drugs, the accuracy of the dose and any adverse effects on patients is not known. There is a need to develop evidence-based guidance for manipulations of medicines in children

    DC-electric-field-induced and low-frequency electromodulation second-harmonic generation spectroscopy of Si(001)-SiO2_2 interfaces

    Get PDF
    The mechanism of DC-Electric-Field-Induced Second-Harmonic (EFISH) generation at weakly nonlinear buried Si(001)-SiO2_2 interfaces is studied experimentally in planar Si(001)-SiO2_2-Cr MOS structures by optical second-harmonic generation (SHG) spectroscopy with a tunable Ti:sapphire femtosecond laser. The spectral dependence of the EFISH contribution near the direct two-photon E1E_1 transition of silicon is extracted. A systematic phenomenological model of the EFISH phenomenon, including a detailed description of the space charge region (SCR) at the semiconductor-dielectric interface in accumulation, depletion, and inversion regimes, has been developed. The influence of surface quantization effects, interface states, charge traps in the oxide layer, doping concentration and oxide thickness on nonlocal screening of the DC-electric field and on breaking of inversion symmetry in the SCR is considered. The model describes EFISH generation in the SCR using a Green function formalism which takes into account all retardation and absorption effects of the fundamental and second harmonic (SH) waves, optical interference between field-dependent and field-independent contributions to the SH field and multiple reflection interference in the SiO2_2 layer. Good agreement between the phenomenological model and our recent and new EFISH spectroscopic results is demonstrated. Finally, low-frequency electromodulated EFISH is demonstrated as a useful differential spectroscopic technique for studies of the Si-SiO2_2 interface in silicon-based MOS structures.Comment: 31 pages, 14 figures, 1 table, figures are also available at http://kali.ilc.msu.su/articles/50/efish.ht

    Phase-locking of a 2.7-THz quantum cascade laser to a mode-locked erbium-doped fibre laser

    Get PDF
    We demonstrate phase-locking of a 2.7-THz metalmetal waveguide quantum cascade laser (QCL) to an external microwave signal. The reference is the 15th harmonic, generated by a semiconductor superlattice nonlinear device, of a signal at 182 GHz, which itself is generated by a multiplier-chain (x2x3x2) from a microwave synthesizer at 15 GHz. Both laser and reference radiations are coupled into a hot electron bolometer mixer, resulting in a beat signal, which is fed into a phase-lock loop. Spectral analysis of the beat signal (see fig. 1) confirms that the QCL is phase locked. This result opens the possibility to extend heterodyne interferometers into the far-infrared range
    • 

    corecore