229 research outputs found
Overpressure Petroleum System Analysis Northern Area Field ‘’X’’ East Kalimantan
Analysis method of overpressure was known in dilling operation to obtain drilling strategy information. Mahakam Deltaic as main giant gas producer in Indonesia specially located on northern area was studied to gain information about pressure profile area. Analysis Normal Compaction, Overburden Gradient using Eaton and Bower’s method from wireline data is used to define pressure profile. Correlation with drilling event hopefully could established the prediction of pressure profile while drilling without supporting from wireline data. Three pressurre profile area has been detected by combination log data and drilling event which are top lower pressure signature by high gas, transition zone signature by occured gas cut mud due to high gas and hard ovepressure signature by issued well control
Measurement of the Positive Muon Lifetime and Determination of the Fermi Constant to Part-per-Million Precision
We report a measurement of the positive muon lifetime to a precision of 1.0
parts per million (ppm); it is the most precise particle lifetime ever
measured. The experiment used a time-structured, low-energy muon beam and a
segmented plastic scintillator array to record more than 2 x 10^{12} decays.
Two different stopping target configurations were employed in independent
data-taking periods. The combined results give tau_{mu^+}(MuLan) =
2196980.3(2.2) ps, more than 15 times as precise as any previous experiment.
The muon lifetime gives the most precise value for the Fermi constant:
G_F(MuLan) = 1.1663788 (7) x 10^-5 GeV^-2 (0.6 ppm). It is also used to extract
the mu^-p singlet capture rate, which determines the proton's weak induced
pseudoscalar coupling g_P.Comment: Accepted for publication in Phys. Rev. Let
Improved Measurement of the Positive Muon Lifetime and Determination of the Fermi Constant
The mean life of the positive muon has been measured to a precision of 11 ppm
using a low-energy, pulsed muon beam stopped in a ferromagnetic target, which
was surrounded by a scintillator detector array. The result, tau_mu =
2.197013(24) us, is in excellent agreement with the previous world average. The
new world average tau_mu = 2.197019(21) us determines the Fermi constant G_F =
1.166371(6) x 10^-5 GeV^-2 (5 ppm). Additionally, the precision measurement of
the positive muon lifetime is needed to determine the nucleon pseudoscalar
coupling g_P.Comment: As published version (PRL, July 2007
Histone Deacetylase Inhibitors Globally Enhance H3/H4 Tail Acetylation Without Affecting H3 Lysine 56 Acetylation
Histone deacetylase inhibitors (HDACi) represent a promising avenue for cancer therapy. We applied mass spectrometry (MS) to determine the impact of clinically relevant HDACi on global levels of histone acetylation. Intact histone profiling revealed that the HDACi SAHA and MS-275 globally increased histone H3 and H4 acetylation in both normal diploid fibroblasts and transformed human cells. Histone H3 lysine 56 acetylation (H3K56ac) recently elicited much interest and controversy due to its potential as a diagnostic and prognostic marker for a broad diversity of cancers. Using quantitative MS, we demonstrate that H3K56ac is much less abundant than previously reported in human cells. Unexpectedly, in contrast to H3/H4 N-terminal tail acetylation, H3K56ac did not increase in response to inhibitors of each class of HDACs. In addition, we demonstrate that antibodies raised against H3K56ac peptides cross-react against H3 N-terminal tail acetylation sites that carry sequence similarity to residues flanking H3K56
Expression of COX-2, NF-κB-p65, NF-κB-p50 and IKKα in malignant and adjacent normal human colorectal tissue
Peer reviewedPublisher PD
- …