14 research outputs found

    Amplitude analysis of the decays D0 → π+π−π+π− and D0 → π+π−π0π0*

    No full text
    Using e+e− annihilation data corresponding to an integrated luminosity of 2.93 fb−1 taken at the center-of-mass energy √s = 3.773 GeV with the BESIII detector, a joint amplitude analysis is performed on the decays D0 → π+π−π+π− and D0 → π+π−π0π0 (non-η). The fit fractions of individual components are obtained, and large interferences among the dominant components of the decays D0 → a1(1260)π, D0 → π(1300)π, D0 → ρ(770)ρ(770), and D0 → 2(ππ)S are observed in both channels. With the obtained amplitude model, the CP-even fractions of D0 → π+π−π+π− and D0 → π+π−π0π0 (non-η) are determined to be (75.2 ± 1.1stat. ± 1.5syst.) % and (68.9 ± 1.5stat. ± 2.4syst.)%, respectively. The branching fractions of D0 → π+π−π+π− and D0 → π+π−π0π0 (non-η) are measured to be (0.688 ± 0.010stat. ± 0.010syst.)% and (0.951 ± 0.025stat. ± 0.021syst.)%, respectively. The amplitude analysis provides an important model for the binning strategy in measuring the strong phase parameters of D0 → 4π when used to determine the CKM angle γ(φ3) via the B− → DK− decay

    JUNO Sensitivity on Proton Decay pνˉK+p\to \bar\nu K^+ Searches

    Get PDF
    The Jiangmen Underground Neutrino Observatory (JUNO) is a large liquid scintillator detector designed to explore many topics in fundamental physics. In this paper, the potential on searching for proton decay in pνˉK+p\to \bar\nu K^+ mode with JUNO is investigated.The kaon and its decay particles feature a clear three-fold coincidence signature that results in a high efficiency for identification. Moreover, the excellent energy resolution of JUNO permits to suppress the sizable background caused by other delayed signals. Based on these advantages, the detection efficiency for the proton decay via pνˉK+p\to \bar\nu K^+ is 36.9% with a background level of 0.2 events after 10 years of data taking. The estimated sensitivity based on 200 kton-years exposure is 9.6×10339.6 \times 10^{33} years, competitive with the current best limits on the proton lifetime in this channel

    Measurement of integrated luminosity of data collected at 3.773 GeV by BESIII from 2021 to 2024

    No full text
    We present a measurement of the integrated luminosity e+e- of collision data collected by the BESIII detector at the BEPCII collider at a center-of-mass energy of Ecm = 3.773 GeV. The integrated luminosities of the datasets taken from December 2021 to June 2022, from November 2022 to June 2023, and from October 2023 to February 2024 were determined to be 4.995±0.019 fb-1, 8.157±0.031 fb-1, and 4.191±0.016 fb-1, respectively, by analyzing large angle Bhabha scattering events. The uncertainties are dominated by systematic effects, and the statistical uncertainties are negligible. Our results provide essential input for future analyses and precision measurements

    JUNO sensitivity on proton decay pνK+p → νK^{+} searches

    No full text

    JUNO sensitivity on proton decay p → ν K + searches*

    No full text
    The Jiangmen Underground Neutrino Observatory (JUNO) is a large liquid scintillator detector designed to explore many topics in fundamental physics. In this study, the potential of searching for proton decay in the pνˉK+ p\to \bar{\nu} K^+ mode with JUNO is investigated. The kaon and its decay particles feature a clear three-fold coincidence signature that results in a high efficiency for identification. Moreover, the excellent energy resolution of JUNO permits suppression of the sizable background caused by other delayed signals. Based on these advantages, the detection efficiency for the proton decay via pνˉK+ p\to \bar{\nu} K^+ is 36.9% ± 4.9% with a background level of 0.2±0.05(syst)±0.2\pm 0.05({\rm syst})\pm 0.2(stat) 0.2({\rm stat}) events after 10 years of data collection. The estimated sensitivity based on 200 kton-years of exposure is 9.6×1033 9.6 \times 10^{33} years, which is competitive with the current best limits on the proton lifetime in this channel and complements the use of different detection technologies
    corecore