171 research outputs found

    Skin-Integrated wearable systems and implantable biosensors: a comprehensive review

    Get PDF
    Biosensors devices have attracted the attention of many researchers across the world. They have the capability to solve a large number of analytical problems and challenges. They are future ubiquitous devices for disease diagnosis, monitoring, treatment and health management. This review presents an overview of the biosensors field, highlighting the current research and development of bio-integrated and implanted biosensors. These devices are micro- and nano-fabricated, according to numerous techniques that are adapted in order to offer a suitable mechanical match of the biosensor to the surrounding tissue, and therefore decrease the body’s biological response. For this, most of the skin-integrated and implanted biosensors use a polymer layer as a versatile and flexible structural support, combined with a functional/active material, to generate, transmit and process the obtained signal. A few challenging issues of implantable biosensor devices, as well as strategies to overcome them, are also discussed in this review, including biological response, power supply, and data communication.This research was funded by FCT- FUNDAÇÃO PARA A CIÊNCIA E TECNOLOGIA, grant numbers: PTDC/EMD-EMD/31590/2017 and PTDC/BTM-ORG/28168/2017

    Highly compliant planar Hall effect sensor with sub 200 nT sensitivity

    Get PDF
    Being a facet of flexible electronics, mechanically reshapeable magnetic field sensorics enable novel device ideas for soft robotics, interactive devices for virtual- and augmented reality and point of care diagnostics. These applications demand mechanically compliant yet robust sensor devices revealing high sensitivity to small magnetic fields. To push the detection limit of highly compliant and linear magnetic field sensors to be in the sub-µT range, we explore a new fundamental concept for magnetic field sensing, namely the planar Hall effect in magnetic thin films. With their remarkable bendability down to 1 mm, these compliant planar Hall effect sensors allow for an efficient detection of magnetic fields as small as 200 nT with a limit of detection of 20 nT. We demonstrate the application potential of these devices as a direction (angle) as well as proximity (distance) sensors of tiny magnetic fields emanating from magnetically functionalized objects. With their intrinsic linearity and simplicity of fabrication, these compliant planar Hall effect sensors have the potential to become a standard solution for low field applications of shapeable magnetoelectronics in point of care applications and on-skin interactive electronics.Fil: Granell, Pablo Nicolás. Instituto Nacional de Tecnología Industrial; Argentina. Universidad Nacional de San Martín. Escuela de Ciencia y Tecnología; ArgentinaFil: Wang, Guoliang. Institute of Ion Beam Physics and Materials Research; AlemaniaFil: Cañon Bermudez, Gilbert Santiago. Institute of Ion Beam Physics and Materials Research; AlemaniaFil: Kosub, Tobias. Institute of Ion Beam Physics and Materials Research; AlemaniaFil: Golmar, Federico. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Martín. Escuela de Ciencia y Tecnología; ArgentinaFil: Steren, Laura Beatriz. Consejo Nacional de Investigaciones Cientificas y Tecnicas. Oficina de Coordinacion Administrativa Ciudad Universitaria. Unidad Ejecutora Instituto de Nanociencia y Nanotecnologia. Unidad Ejecutora Instituto de Nanociencia y Nanotecnologia - Nodo Constituyentes | Comision Nacional de Energia Atomica. Unidad Ejecutora Instituto de Nanociencia y Nanotecnologia. Unidad Ejecutora Instituto de Nanociencia y Nanotecnologia - Nodo Constituyentes.; ArgentinaFil: Fassbender, Jürgen. Institute of Ion Beam Physics and Materials Research; AlemaniaFil: Makarov, Denys. Institute of Ion Beam Physics and Materials Research; Alemani

    소형동물의 뇌신경 자극을 위한 완전 이식형 신경자극기

    Get PDF
    학위논문(박사)--서울대학교 대학원 :공과대학 전기·정보공학부,2020. 2. 김성준.In this study, a fully implantable neural stimulator that is designed to stimulate the brain in the small animal is described. Electrical stimulation of the small animal is applicable to pre-clinical study, and behavior study for neuroscience research, etc. Especially, behavior study of the freely moving animal is useful to observe the modulation of sensory and motor functions by the stimulation. It involves conditioning animal's movement response through directional neural stimulation on the region of interest. The main technique that enables such applications is the development of an implantable neural stimulator. Implantable neural stimulator is used to modulate the behavior of the animal, while it ensures the free movement of the animals. Therefore, stable operation in vivo and device size are important issues in the design of implantable neural stimulators. Conventional neural stimulators for brain stimulation of small animal are comprised of electrodes implanted in the brain and a pulse generation circuit mounted on the back of the animal. The electrical stimulation generated from the circuit is conveyed to the target region by the electrodes wire-connected with the circuit. The devices are powered by a large battery, and controlled by a microcontroller unit. While it represents a simple approach, it is subject to various potential risks including short operation time, infection at the wound, mechanical failure of the device, and animals being hindered to move naturally, etc. A neural stimulator that is miniaturized, fully implantable, low-powered, and capable of wireless communication is required. In this dissertation, a fully implantable stimulator with remote controllability, compact size, and minimal power consumption is suggested for freely moving animal application. The stimulator consists of modular units of surface-type and depth-type arrays for accessing target brain area, package for accommodating the stimulating electronics all of which are assembled after independent fabrication and implantation using customized flat cables and connectors. The electronics in the package contains ZigBee telemetry for low-power wireless communication, inductive link for recharging lithium battery, and an ASIC that generates biphasic pulse for neural stimulation. A dual-mode power-saving scheme with a duty cycling was applied to minimize the power consumption. All modules were packaged using liquid crystal polymer (LCP) to avoid any chemical reaction after implantation. To evaluate the fabricated stimulator, wireless operation test was conducted. Signal-to-Noise Ratio (SNR) of the ZigBee telemetry were measured, and its communication range and data streaming capacity were tested. The amount of power delivered during the charging session depending on the coil distance was measured. After the evaluation of the device functionality, the stimulator was implanted into rats to train the animals to turn to the left (or right) following a directional cue applied to the barrel cortex. Functionality of the device was also demonstrated in a three-dimensional maze structure, by guiding the rats to navigate better in the maze. Finally, several aspects of the fabricated device were discussed further.본 연구에서는 소형 동물의 두뇌를 자극하기 위한 완전 이식형 신경자극기가 개발되었다. 소형 동물의 전기자극은 전임상 연구, 신경과학 연구를 위한 행동연구 등에 활용된다. 특히, 자유롭게 움직이는 동물을 대상으로 한 행동 연구는 자극에 의한 감각 및 운동 기능의 조절을 관찰하는 데 유용하게 활용된다. 행동 연구는 두뇌의 특정 관심 영역을 직접적으로 자극하여 동물의 행동반응을 조건화하는 방식으로 수행된다. 이러한 적용을 가능케 하는 핵심기술은 이식형 신경자극기의 개발이다. 이식형 신경자극기는 동물의 움직임을 방해하지 않으면서도 그 행동을 조절하기 위해 사용된다. 따라서 동물 내에서의 안정적인 동작과 장치의 크기가 이식형 신경자극기를 설계함에 있어 중요한 문제이다. 기존의 신경자극기는 두뇌에 이식되는 전극 부분과, 동물의 등 부분에 위치한 회로부분으로 구성된다. 회로에서 생산된 전기자극은 회로와 전선으로 연결된 전극을 통해 목표 지점으로 전달된다. 장치는 배터리에 의해 구동되며, 내장된 마이크로 컨트롤러에 의해 제어된다. 이는 쉽고 간단한 접근방식이지만, 짧은 동작시간, 이식부위의 감염이나 장치의 기계적 결함, 그리고 동물의 자연스러운 움직임 방해 등 여러 문제점을 야기할 수 있다. 이러한 문제의 개선을 위해 무선통신이 가능하고, 저전력, 소형화된 완전 이식형 신경자극기의 설계가 필요하다. 본 연구에서는 자유롭게 움직이는 동물에 적용하기 위하여 원격 제어가 가능하며, 크기가 작고, 소모전력이 최소화된 완전이식형 자극기를 제시한다. 설계된 신경자극기는 목표로 하는 두뇌 영역에 접근할 수 있는 표면형 전극과 탐침형 전극, 그리고 자극 펄스 생성 회로를 포함하는 패키지 등의 모듈들로 구성되며, 각각의 모듈은 독립적으로 제작되어 동물에 이식된 뒤 케이블과 커넥터로 연결된다. 패키지 내부의 회로는 저전력 무선통신을 위한 지그비 트랜시버, 리튬 배터리의 재충전을 위한 인덕티브 링크, 그리고 신경자극을 위한 이상성 자극파형을 생성하는 ASIC으로 구성된다. 전력 절감을 위해 두 개의 모드를 통해 사용률을 조절하는 방식이 장치에 적용된다. 모든 모듈들은 이식 후의 생물학적, 화학적 안정성을 위해 액정 폴리머로 패키징되었다. 제작된 신경자극기를 평가하기 위해 무선 동작 테스트가 수행되었다. 지그비 통신의 신호 대 잡음비가 측정되었으며, 해당 통신의 동작거리 및 데이터 스트리밍 성능이 검사되었고, 장치의 충전이 수행될 때 코일간의 거리에 따라 전송되는 전력의 크기가 측정되었다. 장치의 평가 이후, 신경자극기는 쥐에 이식되었으며, 해당 동물은 이식된 장치를 이용해 방향 신호에 따라 좌우로 이동하도록 훈련되었다. 또한, 3차원 미로 구조에서 쥐의 이동방향을 유도하는 실험을 통하여 장치의 기능성을 추가적으로 검증하였다. 마지막으로, 제작된 장치의 특징이 여러 측면에서 심층적으로 논의되었다.Chapter 1 : Introduction 1 1.1. Neural Interface 2 1.1.1. Concept 2 1.1.2. Major Approaches 3 1.2. Neural Stimulator for Animal Brain Stimulation 5 1.2.1. Concept 5 1.2.2. Neural Stimulator for Freely Moving Small Animal 7 1.3. Suggested Approaches 8 1.3.1. Wireless Communication 8 1.3.2. Power Management 9 1.3.2.1. Wireless Power Transmission 10 1.3.2.2. Energy Harvesting 11 1.3.3. Full implantation 14 1.3.3.1. Polymer Packaging 14 1.3.3.2. Modular Configuration 16 1.4. Objectives of This Dissertation 16 Chapter 2 : Methods 18 2.1. Overview 19 2.1.1. Circuit Description 20 2.1.1.1. Pulse Generator ASIC 21 2.1.1.2. ZigBee Transceiver 23 2.1.1.3. Inductive Link 24 2.1.1.4. Energy Harvester 25 2.1.1.5. Surrounding Circuitries 26 2.1.2. Software Description 27 2.2. Antenna Design 29 2.2.1. RF Antenna 30 2.2.1.1. Design of Monopole Antenna 31 2.2.1.2. FEM Simulation 31 2.2.2. Inductive Link 36 2.2.2.1. Design of Coil Antenna 36 2.2.2.2. FEM Simulation 38 2.3. Device Fabrication 41 2.3.1. Circuit Assembly 41 2.3.2. Packaging 42 2.3.3. Electrode, Feedthrough, Cable, and Connector 43 2.4. Evaluations 45 2.4.1. Wireless Operation Test 46 2.4.1.1. Signal-to-Noise Ratio (SNR) Measurement 46 2.4.1.2. Communication Range Test 47 2.4.1.3. Device Operation Monitoring Test 48 2.4.2. Wireless Power Transmission 49 2.4.3. Electrochemical Measurements In Vitro 50 2.4.4. Animal Testing In Vivo 52 Chapter 3 : Results 57 3.1. Fabricated System 58 3.2. Wireless Operation Test 59 3.2.1. Signal-to-Noise Ratio Measurement 59 3.2.2. Communication Range Test 61 3.2.3. Device Operation Monitoring Test 62 3.3. Wireless Power Transmission 64 3.4. Electrochemical Measurements In Vitro 65 3.5. Animal Testing In Vivo 67 Chapter 4 : Discussion 73 4.1. Comparison with Conventional Devices 74 4.2. Safety of Device Operation 76 4.2.1. Safe Electrical Stimulation 76 4.2.2. Safe Wireless Power Transmission 80 4.3. Potential Applications 84 4.4. Opportunities for Further Improvements 86 4.4.1. Weight and Size 86 4.4.2. Long-Term Reliability 93 Chapter 5 : Conclusion 96 Reference 98 Appendix - Liquid Crystal Polymer (LCP) -Based Spinal Cord Stimulator 107 국문 초록 138 감사의 글 140Docto

    Wireless thin film transistor based on micro magnetic induction coupling antenna

    Get PDF
    A wireless thin film transistor (TFT) structure in which a source/drain or a gate is connected directly to a micro antenna to receive or transmit signals or power can be an important building block, acting as an electrical switch, a rectifier or an amplifier, for various electronics as well as microelectronics, since it allows simple connection with other devices, unlike conventional wire connections. An amorphous indium gallium zinc oxide (α-IGZO) TFT with magnetic antenna structure was fabricated and studied for this purpose. To enhance the induction coupling efficiency while maintaining the same small antenna size, a magnetic core structure consisting of Ni and nanowires was formed under the antenna. With the micro-antenna connected to a source/drain or a gate of the TFT, working electrical signals were well controlled. The results demonstrated the device as an alternative solution to existing wire connections which cause a number of problems in various fields such as flexible/wearable devices, body implanted devices, micro/nano robots, and sensors for the 'internet of things' (IoT).1

    Doctor of Philosophy

    Get PDF
    dissertationThis thesis presents the design, fabrication and characterization of a microelectromechanical system (MEMS) based complete wireless microsystem for brain interfacing, with very high quality factor and low power consumption. Components of the neuron sensing system include TiW fixed-fixed bridge resonator, MEMS oscillator based action-potential-to-RF module, and high-efficiency RF coil link for power and data transmissions. First, TiW fixed-fixed bridge resonator on glass substrate was fabricated and characterized, with resonance frequency of 100 - 500 kHz, and a quality factor up to 2,000 inside 10 mT vacuum. The effect of surface conditions on resonator's quality factor was studied with 10s of nm Al2O3 layer deposition with ALD (atomic layer deposition). It was found that MEMS resonator's quality factor decreased with increasing surface roughness. Second, action-potential-to-RF module was realized with MEMS oscillator based on TiW bridge resonator. Oscillation signal with frequency of 442 kHz and phase noise of -84.75 dBc/Hz at 1 kHz offset was obtained. DC biasing of the MEMS oscillator was modulated with neural signal so that the output RF waveform carries the neural signal information. Third, high-efficiency RF coil link for power and data communications was designed and realized. Based on the coupled mode theory (CMT), intermediate resonance coil was introduced and increased voltage transfer efficiency by up to 5 times. Finally, a complete neural interfacing system was demonstrated with board-level integration. The system consists of both internal and external systems, with wireless powering, wireless data transfer, artificial neuron signal generation, neural signal modulation and demodulation, and computer interface displaying restored neuron signal

    Photovoltaic power harvesting technologies in biomedical implantable devices considering the optimal location

    Get PDF
    here are still many challenges in effectively harvesting and generating power for implantable medical devices. Most of today's research focuses on finding ways to harvest energy from the human body to avoid the use of batteries, which require surgical replacement. For example, current energy harvesters rely on piezoelectricity, thermoelectricity and solar electricity to drive the implantable device. However, the majority of these energy harvesting techniques suffer from a variety of limitations such as low power output, large size or poor efficiency. Due to their high efficiency, we focus our attention on solar photovoltaic cells. We demonstrate the tissue absorption losses severely influence their performance. We predict the performance of these cells using simulation through the verified experimental data. Our results show that our model can obtain 17.20% efficiency and 0.675 V open-circuit voltage in one sun condition. In addition, our device can also harvest up to 15 mW/ cm2 in dermis and 11.84 mW/ cm2 in hypodermis by using 100 mW/ cm2 light source at 800 nm and 850 nm, respectively. We propose implanting our device in hypodermis to obtain a stable power output

    Magnetosensitive e-skins for interactive electronics

    Get PDF
    The rapid progress of electronics and computer science in the last years has brought humans and machines closer than ever before. Current trends like the Internet of Things and artificial intelligence are closing the gap even further, by providing ubiquitous data processing and sensing. As this ongoing revolution advances, novel forms of human-machine interactions are required in an ever more connected world. A crucial component to enable these interactions is the field of flexible electronics, which aims to establish a seamless link between living and artificial entities using electronic skins (e-skins). E-skins combine the functionality of commercial electronics with the soft, stretchable and biocompatible characteristics of human skin or tissue. Until lately, the focus had been to replicate the standard functions associated with human skin, such as, temperature, pressure and chemical detection. Yet, recent developments have also introduced non-standard sensing capabilities like magnetic field detection to create the field of magnetosensitive e-skins. The addition of a supplementary information channel—an electronic sixth sense—has sparked a wide range of applications in the fields of cognitive psychology and human-machine interactions. In this thesis, we expand the concept of magnetosensitive e-skins to include the notion of directionality, which utilizes the full interaction potential of the magnetic field vector. Also, we introduce the use of flexible magnetoelectronics in virtual/augmented reality and human-computer interfaces. Three main results are attained in the course of this work: (i) we first demonstrate how magnetosensitive e-skins can be used as humanmachine interfaces driven by permanent magnet sources in the range of 5 mT. (ii) Building upon this milestone, we realize the first magnetosensitive e-skins which are driven by the earth’s magnetic field of 50 μT. (iii) We fabricate magnetosensitive e-skins which push the detection limit below 1 μT. The magnetosensitive e-skins in this work open exciting possibilities for sensory substitution experiments and sensory processing disorder therapies. Futhermore, for human-machine interactions, they provide a new interactive platform for touchless and gestural control in virtual and augmented reality scenarios beyond the limitations of optics-based systems.Der rasante Fortschritt der Elektronik und der Informatik in den letzten Jahren hat Mensch und Maschine nähergebracht als je zuvor. Aktuelle Trends wie das Internet der Dinge und künstliche Intelligenz schließen die Lücke noch weiter, indem sie eine allgegenwärtige Datenverarbeitung und -erfassung ermöglichen. Mit fortschreitender Revolution sind neue Formen der Mensch-Maschine-Interaktion in einer immer vernetzter werdenden Welt erforderlich. Eine entscheidende Komponente, um diese Interaktionen zu ermöglichen, ist das Gebiet der flexiblen Elektronik, das darauf abzielt, mithilfe elektronischer Häute (e-skins) eine nahtlose Verbindung zwischen lebenden und künstlichen Entitäten herzustellen. E-skins verbinden die Funktionalität kommerzieller Elektronik mit den weichen, dehnbaren und biokompatiblen Eigenschaften menschlicher Haut oder menschlichen Gewebes. Bis vor kurzem lag der Schwerpunkt auf der Nachbildung der mit der menschlichen Haut verbundenen Standardfunktionen wie Temperatur-, Druck- und Chemikalienerkennung. Jüngste Entwicklungen haben jedoch auch nicht standardmäßige Erfassungsfähigkeiten wie die Magnetfelderkennung eingeführt, um das Feld magnetoempfindlicher e-skins zu erzeugen. Die Hinzufügung eines zusätzlichen Informationskanals - eines elektronischen sechsten Sinns - hat eine breite Palette von Anwendungen auf den Gebieten der kognitiven Psychologie und der Mensch-Maschine-Interaktionen ausgelöst. In dieser Arbeit erweitern wir das Konzept der magnetoempfindlichen e-skins um den Begriff der Richtwirkung, bei dem das volle Wechselwirkungspotential des Magnetfeldvektors genutzt wird. Außerdem führen wir die Verwendung flexibler Magnetoelektronik in der virtuellen Realität / erweiterten Realität und in Mensch-Computer-Schnittstellen ein. Im Verlauf dieser Arbeit werden drei Hauptergebnisse erzielt: (i) Wir demonstrieren erstmals, wie magnetoempfindliche e-skins als Mensch-Maschine-Schnittstellen verwendet werden können, die von Permanentmagnetquellen im Bereich von 5 mT angetrieben werden. (ii) Aufbauend auf diesem Meilenstein realisieren wir die ersten magnetoempfindlichen e-skins, die vom Erdmagnetfeld von 50 μT angetrieben werden. (iii) Wir fertigen magnetoempfindliche e-skins, bei denen die Nachweisgrenze unter 1 μT liegt. Die magnetoempfindlichen e-skins in dieser Arbeit eröffnen aufregende Möglichkeiten für sensorische Substitutionsexperimente und Therapien bei sensorischen Verarbeitungsstörungen. Darüber hinaus bieten sie für die Mensch-Maschine-Interaktion eine neue interaktive Plattform für die berührungslose und gestische Steuerung in virtuellen und Augmented Reality-Szenarien, die über die Grenzen optikbasierter Systeme hinausgehen

    Wireless Power and Communication Transmission for Industrial Robots

    Get PDF
    Mid-range resonant wireless power transfer (WPT) gained tremendous attention due to the higher efficiency. However, the relatively narrow transmission band has been simply drawn the technology back from being implemented in an application where the data and a power transmission are required. In this paper both the simulation and a practical implementation of a Strongly Coupled Magnetic Resonant (SCMR) system with a high frequency band for simultaneous data and power transmission is proposed. With this method communication and a power transmission can be transmitted in an industrial robot applications. Multiple TX and a single RX loop are placed between the joint of the robot in order to increase frequency spectre. The simulation has been developed in the theoretical analysis of equivalent circuits of the improved SCMR system. The analysis eventually leads to the factual parameters of a WPT system to provide its maximum efficiency for both wireless power and data transmission for an industrial robot. Besides the analysis has been validated with a comparison between the simulation results and practical implementation

    Wireless Power and Communication Transmission for Industrial Robots

    Get PDF
    Mid-range resonant wireless power transfer (WPT) gained tremendous attention due to the higher efficiency. However, the relatively narrow transmission band has been simply drawn the technology back from being implemented in an application where the data and a power transmission are required. In this paper both the simulation and a practical implementation of a Strongly Coupled Magnetic Resonant (SCMR) system with a high frequency band for simultaneous data and power transmission is proposed. With this method communication and a power transmission can be transmitted in an industrial robot applications. Multiple TX and a single RX loop are placed between the joint of the robot in order to increase frequency spectre. The simulation has been developed in the theoretical analysis of equivalent circuits of the improved SCMR system. The analysis eventually leads to the factual parameters of a WPT system to provide its maximum efficiency for both wireless power and data transmission for an industrial robot. Besides the analysis has been validated with a comparison between the simulation results and practical implementation
    corecore