12 research outputs found

    AC voltage regulation of a bidirectional high-frequency link converter using a deadbeat controller

    Get PDF
    This paper presents a digital controller for AC voltage regulation of a bidirectional high-frequency link (BHFL) inverter using Deadbeat control. The proposed controller consists of inner current loop, outer voltage loop and a feed-forward controller, which imposes a gain scheduling effect according to the reference signal to compensate the steady-state error of the system. The main property of the proposed controller is that the current- and the voltage-loop controllers have the same structure, and use the same sampling period. This simplifies the design and implementation processes. To improve the overall performance of the system, additional disturbance decoupling networks are employed. This takes into account the model discretization effect. Therefore, accurate disturbance decoupling can be achieved, and the system robustness towards load variations is increased. To avoid transformer saturation due to low frequency voltage envelopes, an equalized pulse width modulation (PWM) technique has been introduced. The proposed controller has been realized using the DS1104 digital signal processor (DSP) from dSPACE. Its performances have been tested on a one kVA prototype inverter. Experimental results showed that the proposed controller has very fast dynamic and good steady-state responses even under highly nonlinear loads

    Intelligent UPS Inverter Control Design Using Microcontroller

    Get PDF
    This paper presents many control algorithms using microcontroller for an uninterruptible power supply (UPS) inverter, in order to provide pure sinusoidal wave 50 Hz, controlled by the PIC-microcontroller. The strategy is to utilize the PIC microcontroller and its special features in controlling the UPS inverter. The first approach accomplished with a classical control Proportional-Integral-Derivative (PID) algorithm. The second approach accomplished with the Fuzzy Logic Control (FLC). The third approach accomplished with nonlinear PID-fuzzy logic controller. The ability of the proposed scheme is validated via a successful implementation on a microcontroller-based UPS inverter. The proposed scheme has shown its robustness on low output voltage distortion, excellent voltage regulation, and it is insensitive to load variation, even under nonlinear loads. Experimental studies are performed to further validate the effectiveness of this scheme. This system may be used with grid-solar energy systems. Keywords: PID Controller, Fuzzy Logic Control, Nonlinear PID-Fuzzy Logic, Takagi Sugeno, Microcontroller Application

    AC Voltage Regulation of a Bidirectional High-Frequency Link Converter Using a Deadbeat Controller

    Get PDF
    This paper presents a digital controller for ac voltage regulation of a bidirectional high-frequency link (BHFL) inverter using deadbeat control. The proposed controller consists of inner current loop, outer voltage loop and a feed-forward controller, which imposes a gain scheduling effect according to the reference signal to compensate the steady-state error of the system. The main property of the proposed controller is that the current- and the voltage-loop controllers have the same structure, and use the same sampling period. This simplifies the design and implementation processes. To improve the overall performance of the system, additional disturbance decoupling networks are employed. This takes into account the model discretization effect. Therefore, accurate disturbance decoupling can be achieved, and the system robustness towards load variations is increased. To avoid transformer saturation due to low frequency voltage envelopes, an equalized pulse width modulation (PWM) technique has been introduced. The proposed controller has been realized using the DS1104 digital signal processor (DSP) from dSPACE. Its performances have been tested on a one kVA prototype inverter. Experimental results showed that the proposed controller has very fast dynamic and good steady-state responses even under highly nonlinear load

    Control of power electronic interfaces in distributed generation.

    Get PDF
    Renewable energy has gained popularity as an alternative resource for electric power generation. As such, Distributed Generation (DG) is expected to open new horizons to electric power generation. Most renewable energy sources cannot be connected to the load directly. Integration of the renewable energy sources with the load has brought new challenges in terms of the system’s stability, voltage regulation and power quality issues. For example, the output power, voltage and frequency of an example wind turbine depend on the wind speed, which fluctuate over time and cannot be forecasted accurately. At the same time, the nonlinearity of residential electrical load is steadily increasing with the growing use of devices with rectifiers at their front end. This nonlinearity of the load deviates both current and voltage waveforms in the distribution feeder from their sinusoidal shape, hence increasing the Total Harmonics Distortions (THD) and polluting the grid. Advances in Power Electronic Interfaces (PEI) have increased the viability of DG systems and enhanced controllability and power transfer capability. Power electronic converter as an interface between energy sources and the grid/load has a higher degree of controllability compared to electrical machine used as the generator. This controllability can be used to not only overcome the aforementioned shortfalls of integration of renewable energy with the grid/load but also to reduce THD and improve the power quality. As a consequence, design of a sophisticated controller that can take advantage of this controllability provided by PEIs to facilitate the integration of DG with the load and generate high quality power has become of great interest. In this study a set of nonlinear controllers and observers are proposed for the control of PEIs with different DG technologies. Lyapunov stability analysis, simulation and experimental results are used to validate the effectiveness of the proposed control solution in terms of tracking objective and meeting the THD requirements of IEEE 519 and EN 50160 standards for US and European power systems, respectively

    Control of high performance single phase DC-AC inverter

    Get PDF
    Master'sMASTER OF ENGINEERIN

    A Virtual Space Vectors based Model Predictive Control for Three-Level Converters

    Get PDF
    Three-phase three-level (3-L) voltage source converters (VSC), e.g., neutral-point clamped (NPC) converters, T-type converters, etc., have been deemed to be suitable for a wide range of medium- to high-power applications in microgrids (MGs) and bulk power systems. Compared to their two-level (2-L) counterparts, adopting 3-L VSCs in the MG applications not only reduces the voltage stress across the power semiconductor devices, which allows achieving higher voltage levels, but also improves the quality of the converter output waveforms, which further leads to considerably smaller output ac passive filters. Various control strategies have been proposed and implemented for 3-L VSCs. Among all the existing control methods, finite-control-set model predictive control (FCS-MPC) has been extensively investigated and applied due to its simple and intuitive design, fast-dynamic response and robustness against parameter uncertainties. However, to implement an FCS-MPC on a 3-L VSC, a multi-objective cost function, which consists of a term dedicated specifically to control the dc-link capacitor voltages such that the neutral-point voltage (NP-V) oscillations are minimized, must be designed. Nevertheless, selecting proper weighting factors for the multiple control objectives is difficult and time consuming. Additionally, adding the dc-link capacitor voltages balancing term to the cost function distributes the controller effort among different control targets, which severely impacts the primary goal of the FCS-MPC. Furthermore, to control the dc-link capacitor voltages, additional sensing circuitries are usually necessary to measure the dc-link capacitor voltages and currents, which consequently increases the system cost, volume and wiring complexity as well as reduces overall reliability. To address all the aforementioned challenges, in this dissertation research, a novel FCS-MPC method using virtual space vectors (VSVs), which do not affect the dc-link capacitor voltages of the 3-L VSCs, was proposed, implemented and validated. The proposed FCS-MPC strategy has the capability to achieve inherent balanced dc-link capacitor voltages. Additionally, the demonstrated control technique not only simplifies the controller design by allowing the use of a simplified cost function, but also improves the quality of the 3-L VSC output waveforms. Furthermore, the execution time of the proposed control algorithm was significantly reduced compared to that of the existing one. Lastly, the proposed FCS-MPC using the VSVs reduces the hardware cost and complexity as the additional dc-link capacitor voltages and current sensors are not required, which further enhances the overall system reliability

    Uncertainty and disturbance estimator design to shape and reduce the output impedance of inverter

    Get PDF
    Power inverters are becoming more and more common in the modern grid. Due to their switching nature, a passive filter is installed at the inverter output. This generates high output impedance which limits the inverter ability to maintain high power quality at the inverter output. This thesis deals with an impedance shaping approach to the design of power inverter control. The Uncertainty and Disturbance Estimator (UDE) is proposed as a candidate for direct formation of the inverter output impedance. The selection of UDE is motivated by the desire for the disturbance rejection control and the tracking controller to be decoupled. It is demonstrated in the thesis that due to this fact the UDE filter design directly influences the inverter output impedance and the reference model determines the inverter internal electromotive force. It was recently shown in the literature and further emphasized in this thesis that the classic low pass frequency design of the UDE cannot estimate periodical disturbances under the constraint of finite control bandwidth. Since for a power inverter both the reference signal and the disturbance signal are of periodical nature, the classic UDE lowpass filter design does not give optimal results. A new design approach is therefore needed. The thesis develops four novel designs of the UDE filter to significantly reduce the inverter output impedance and maintain low Total Harmonic Distortion (THD) of the inverter output voltage. The first design is the based on a frequency selective filter. This filter design shows superiority in both observing and rejecting periodical disturbances over the classic low pass filter design. The second design uses a multi-band stop design to reject periodical disturbances with some uncertainty in the frequency. The third solution uses a classic low pass filter design combined with a time delay to match zero phase estimation of the disturbance at the relevant spectrum. Furthermore, this solution is combined with a resonant tracking controller to reduce the tracking steady-state error in the output voltage. The fourth solution utilizes a low-pass filter combined with multiple delays to increase the frequency robustness. This method shows superior performance over the multi-band-stop and the time delayed filter in steady-state. All the proposed methods are validated through extensive simulation and experimental results
    corecore