952 research outputs found

    Cystic lesions in multislice computed tomography of the chest: A diagnostic approach

    Get PDF
    AbstractPurposeTo evaluate the role of Multislice Computed Tomography (MSCT) in the detection, diagnosis and differentiation of possible causes of chest cystic lesions using different capabilities of MSCT.Patients and methodsThe study involved 43 patients. Clinical examination, history taking, relevant laboratory data, pulmonary function test if needed, together with different techniques of MSCT according to the assessed case were done to reach the possible diagnosis, and then pathology assessment was needed in 11 cases.ResultsMSCT showed that 30 (70%) of cases were lung cysts, 5 (12%) of cases were mediastinal, 4 (9%) of cases were pleural and 4 (9%) of cases were chest wall. 25 (42%) of cases were with single cyst and 18 (58%) of cases were with multiple cysts. 23 (47%) of cases were with air containing cysts and 20 (53%) of cases were with fluid containing cysts. We discussed the differentiating MSCT features of various cystic lesions and the approach used to reach final diagnosis.ConclusionCystic lesions of the thorax have a wide range of differential diagnosis, and to reach the cause a multidisciplinary approach should be done. The role of MSCT imaging is essential in diagnosis and evaluation of different chest cystic lesions

    Chest CT in patients after lung transplantation: A retrospective analysis to evaluate impact on image quality and radiation dose using spectral filtration tin-filtered imaging.

    Get PDF
    OBJECTIVES: The purpose of this study was to investigate the impact of a 150kV spectral filtration chest imaging protocol (Sn150kVp) combined with advanced modeled iterative reconstruction (ADMIRE) on radiation dose and image quality in patients after lung-transplantation. METHODS: This study included 102 patients who had unenhanced chest-CT examinations available on both, a second-generation dual-source CT (DSCT) using standard protocol (100kVp, filtered-back-projection) and, on a third-generation DSCT using Sn150kVp protocol with ADMIRE. Signal-to-noise-ratio (SNR) was measured in 6 standardized regions. A 5-point Likert scale was used to evaluate subjective image quality. Radiation metrics were compared. RESULTS: The mean time interval between the two acquisitions was 1.1±0.7 years. Mean-volume-CT-dose-index, dose-length-product and effective dose were significantly lower for Sn150kVp protocol (2.1±0.5mGy;72.6±16.9mGy*cm;1.3±0.3mSv) compared to 100kVp protocol (6.2±1.8mGy;203.6±55.6mGy*cm;3.7±1.0mSv) (p<0.001), equaling a 65% dose reduction. All studies were considered of diagnostic quality. SNR measured in lung tissue, air inside trachea, vertebral body and air outside the body was significantly higher in 100kVp protocol compared to Sn150kVp protocol (12.5±2.7vs.9.6±1.5;17.4±3.6vs.11.8±1.8;0.7±0.3vs.0.4±0.2;25.2±6.9vs.14.9±3.3;p<0.001). SNR measured in muscle tissue was significantly higher in Sn150kVp protocol (3.2±0.9vs.2.6±1.0;p<0.001). For SNR measured in descending aorta there was a trend towards higher values for Sn150kVp protocol (2.8±0.6 vs. 2.7±0.9;p = 0.3). Overall SNR was significantly higher in 100kVp protocol (5.0±4.0vs.4.0±4.0;p<0.001). On subjective analysis both protocols achieved a median Likert rating of 1 (25th-75th-percentile:1-1;p = 0.122). Interobserver agreement was good (intraclass correlation coefficient = 0.73). CONCLUSIONS: Combined use of 150kVp tin-filtered chest CT protocol with ADMIRE allows for significant dose reduction while maintaining highly diagnostic image quality in the follow up after lung transplantation when compared to a standard chest CT protocol using filtered back projection

    Image quality and dosimetry of a dual source computed tomography scanner with special emphasis on radiation dose of lung in a chest examination

    Get PDF
    The purpose of the current study was to evaluate the Dual Source Computed Tomography scanner in terms of Image quality and dosimetry with special emphasis of radiation dose of lung in a Chest examination.Zielsetzung der Studie war die Evaluation eines Dual-Source-Computertomographen hinsichtlich Bildqualität und Dosimetrie mit speziellem Fokus auf der Lungendosis in Thoraxuntersuchungen

    Use of 100 kV versus 120 kV in computed tomography pulmonary angiography in the detection of pulmonary embolism: effect on radiation dose and image quality.

    Get PDF
    Objective: To determine the effective radiation dose and image quality resulting from 100 versus 120 kilovoltage (kV) protocols among patients referred for computed tomography pulmonary angiography (CTPA). Methods: Sixty-six patients with clinical suspicion of pulmonary embolism (PE) were prospectively enrolled. Two CTPA protocols (group A: n=33, 100 kV/115 mAs; group B: n=33, 120 kV/90 mAs) were compared. Two experienced radiologists assessed image quality in terms of diagnostic performance and effect of artefacts. Image quality parameters [CT attenuation, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR)] and effective radiation dose between the two protocols were compared. Results: The contrast enhancement in central and peripheral pulmonary arteries was significantly higher in group A than in group B (P<0.001) with the identical SNR (P=0.26), whereas the CNR was significantly higher in group A than in group B (P<0.001). The effective radiation dose for the 100 and 120 kV scans was 3.2 and 6.8 mSv, respectively. Conclusions: Reducing the tube voltage from 120 to 100 kV in CTPA allows a significant reduction of radiation dose without significant loss of diagnostic image quality

    Radiation exposure from Chest CT: Issues and Strategies

    Get PDF
    Concerns have been raised over alleged overuse of CT scanning and inappropriate selection of scanning methods, all of which expose patients to unnecessary radiation. Thus, it is important to identify clinical situations in which techniques with lower radiation dose such as plain radiography or no radiation such as MRI and occasionally ultrasonography can be chosen over CT scanning. This article proposes the arguments for radiation dose reduction in CT scanning of the chest and discusses recommended practices and studies that address means of reducing radiation exposure associated with CT scanning of the chest

    Systematic review of the clinical effectiveness and cost-effectiveness of 64-slice or higher computed tomography angiography as an alternative to invasive coronary angiography in the investigation of coronary artery disease

    Get PDF
    Objectives: To assess the clinical effectiveness and cost-effectiveness, in different patient groups, of the use of 64-slice or higher computed tomography (CT) angiography, instead of invasive coronary angiography (CA), for diagnosing people with suspected coronary artery disease (CAD) and assessing people with known CAD. Data sources: Electronic databases were searched from 2002 to December 2006. Review methods: Included studies were tabulated and sensitivity, specificity, positive and negative predictive values calculated. Meta-analysis models were fitted using hierarchical summary receiver operating characteristic curves. Summary sensitivity, specificity, positive and negative likelihood ratios and diagnostic odds ratios for each model were reported as a median and 95% credible interval (CrI). Searches were also carried out for studies on the cost-effectiveness of 64-slice CT in the assessment of CAD. Results: The diagnostic accuracy and prognostic studies enrolled over 2500 and 1700 people, respectively. The overall quality of the studies was reasonably good. In the pooled estimates, 64-slice CT angiography was highly sensitive (99%, 95% CrI 97 to 99%) for patientbased detection of significant CAD (defined as 50% or more stenosis), while across studies the negative predictive value (NPV) was very high (median 100%, range 86 to 100%). In segment-level analysis compared with patient-based detection, sensitivity was lower (90%, 95% CrI 85 to 94%, versus 99%, 95% CrI 97 to 99%) and specificity higher (97%, 95% CrI 95 to 98%, versus 89%, 95% CrI 83 to 94%), while across studies the median NPV was similar (99%, range 95 to 100%, versus 100%, range 86 to 100%). At individual coronary artery level the pooled estimates for sensitivity ranged from 85% for the left circumflex (LCX) artery to 95% for the left main artery, specificity ranged from 96% for both the left anterior descending (LAD) artery and LCX to 100% for the left main artery, while across studies the positive predictive value (PPV) ranged from 81% for the LCX to 100% for the left main artery and NPV was very high, ranging from 98% for the LAD (range 95 to 100%), LCX (range 93 to 100%) and right coronary artery (RCA) (range 94 to 100%) to 100% for the left main artery. The pooled estimates for bypass graft analysis were 99% (95% CrI 95 to 100%) sensitivity, 96% (95% CrI 86 to 99%) specificity, with median PPV and NPV values across studies of 93% (range 90 to 95%) and 99% (range 98 to 100%), respectively. This compares with, for stent analysis, a pooled sensitivity of 89% (95% CrI 68 to 97%), specificity 94% (95% CrI 83 to 98%), and median PPV and NPV values across studies of 77% (range 33 to 100%) and 96% (range 71 to 100%), respectively. Sixty-four-slice CT is almost as good as invasive CA in terms of detecting true positives. However, it is somewhat poorer in its rate of false positives. It seems likely that diagnostic strategies involving 64-slice CT will still require invasive CA for CT test positives, partly to identify CT false positives, but also because CA provides other information that CT currently does not, notably details of insertion site and distal run-off for possible coronary artery bypass graft (CABG). The high sensitivity of 64-slice CT avoids the costs of unnecessary CA in those referred for investigation but who do not have CAD. Given the possible, although small, associated death rate, avoiding these unnecessary CAs through the use of 64-slice CT may also confer a small immediate survival advantage. This in itself may be sufficient to outweigh the very marginally inferior rates of detection of true positives by strategies involving 64-slice CT. The avoidance of unnecessary CA through the use of 64-slice CT also appears likely to result in overall cost savings in the diagnostic pathway. Only if both the cost of CA is relatively low and the prevalence of CAD in the presenting population is relatively high (so that most patients will go on to CA) will the use of 64-slice CT be likely to result in a higher overall diagnostic cost per patient. Conclusions: The main value of 64-slice CT may at present be to rule out significant CAD. It is unlikely to replace CA in assessment for revascularisation of patients, particularly as angiography and angioplasty are often done on the same occasion. Further research is needed into the marginal advantages and costs of 256-slice machines compared with 64-sliceCT, the usefulness of 64-slice CT in people with suspected acute coronary syndrome, the potential of multislice computed tomography to examine plaque morphology, the role of CT in identifying patients suitable for CABG, and the concerns raised about repetitive use, or use of 64-slice or higher CT angiography in younger individuals or women of childbearing age.The Health Services Research Unit, Institute of Applied Health Sciences, University of Aberdeen, is core-funded by the Chief Scientist Office of the Scottish Government Health Directorates

    64-slice computed tomography angiography in the diagnosis and assessment of coronary artery disease : systematic review and meta-analysis

    Get PDF
    Objective To assess whether 64-slice computed tomography (CT) angiography might replace some coronary angiography (CA) for diagnosis and assessment of coronary artery disease (CAD). Methods We searched electronic databases, conference proceedings and scanned reference lists of included studies. Eligible studies compared 64-slice CT with a reference standard of CA in adults with suspected/known CAD, reporting sensitivity and specificity or true and false positives and negatives. Data were pooled using the hierarchical summary receiver operating characteristic model. Results Forty studies were included; 28 provided sufficient data for inclusion in the meta-analyses, all using a cutoff of ≥ 50% stenosis to define significant CAD. In patient-based detection (n=1286) 64-slice CT pooled sensitivity was 99% (95% credible interval (CrI) 97 to 99%), specificity 89% (95% CrI 83 to 94%), median positive predictive value (PPV) across studies 93% (range 64 to 100%) and negative predictive value (NPV) 100% (range 86 to 100%). In segment-based detection (n=14,199) 64-slice CT pooled sensitivity was 90% (95% CrI 85 to 94%), specificity 97% (95% CrI 95 to 98%), median positive predictive value (PPV) across studies 76% (range 44 to 93%) and negative predictive value (NPV) 99% (range 95 to 100%). Conclusions 64-slice CT is highly sensitive for patient-based detection of CAD and has high NPV. An ability to rule out significant CAD means that it may have a role in the assessment of chest pain, particularly when the diagnosis remains uncertain despite clinical evaluation and simple non-invasive testing.UK National Institute for Health Research Health Technology Assessment programme (project number 06/15/01). The Health Services Research Unit is core funded by the Chief Scientist Office of the Scottish Government Health Directorates.Peer reviewedAuthor versio

    Systematic analysis on the relationship between luminal enhancement, convolution kernel, plaque density, and luminal diameter of coronary artery stenosis: a CT phantom study

    Get PDF
    To systematically investigate into the relationships between luminal enhancement, convolution kernel, plaque density, and stenosis severity in coronary computed tomography (CT) angiography. A coronary phantom including 63 stenoses (stenosis severity, 10-90%; plaque densities, −100 to 1,000HU) was loaded with increasing solutions of contrast material (luminal enhancement, 0-700HU) and scanned in an anthropomorphic chest. CT data was acquired with prospective triggering using 64-section dual-source CT; reconstructions were performed with soft-tissue (B26f) and sharp convolution kernels (B46f). Two blinded and independent readers quantitatively assessed luminal diameter and CT number of plaque using electronic calipers. Measurement bias between phantom dimensions and CT measurements were calculated. Multivariate linear regression models identified predictors of bias. Inter- and intra-reader agreements of luminal diameter and CT number measurements were excellent (ICCs>0.91, p200HU. Measurement bias was significantly (p<0.01, each) correlated (ρ=0.37-55 and ρ=−0.70-85) with the differences between luminal enhancement and plaque density. In multivariate models, bias of luminal diameter assessment with CT was correlated with plaque density (β=0.09, p<0.05). Convolution kernel (β=−0.29 and −0.38), stenosis severity (β=−0.45 and −0.38), and luminal enhancement (β=−0.11 and −0.29) represented independent (p<0.05,each) predictors of measurement bias of luminal diameter and plaque number, respectively. Significant independent relationships exist between luminal enhancement, convolution kernel, plaque density, and luminal diameter, which have to be taken into account when performing, evaluating, and interpreting coronary CT angiograph

    Deep Learning Reconstruction Shows Better Lung Nodule Detection for Ultra-Low-Dose Chest CT

    Get PDF
    Background Ultra-low-dose (ULD) CT could facilitate the clinical implementation of large-scale lung cancer screening while minimizing the radiation dose. However, traditional image reconstruction methods are associated with image noise in low-dose acquisitions. Purpose To compare the image quality and lung nodule detectability of deep learning image reconstruction (DLIR) and adaptive statistical iterative reconstruction-V (ASIR-V) in ULD CT. Materials and Methods Patients who underwent noncontrast ULD CT (performed at 0.07 or 0.14 mSv, similar to a single chest radiograph) and contrast-enhanced chest CT (CECT) from April to June 2020 were included in this prospective study. ULD CT images were reconstructed with filtered back projection (FBP), ASIR-V, and DLIR. Three-dimensional segmentation of lung tissue was performed to evaluate image noise. Radiologists detected and measured nodules with use of a deep learning-based nodule assessment system and recognized malignancy-related imaging features. Bland-Altman analysis and repeated-measures analysis of variance were used to evaluate the differences between ULD CT images and CECT images. Results A total of 203 participants (mean age ± standard deviation, 61 years ± 12; 129 men) with 1066 nodules were included, with 100 scans at 0.07 mSv and 103 scans at 0.14 mSv. The mean lung tissue noise ± standard deviation was 46 HU ± 4 for CECT and 59 HU ± 4, 56 HU ± 4, 53 HU ± 4, 54 HU ± 4, and 51 HU ± 4 in FBP, ASIR-V level 40%, ASIR-V level 80% (ASIR-V-80%), medium-strength DLIR, and high-strength DLIR (DLIR-H), respectively, of ULD CT scans (P < .001). The nodule detection rates of FBP reconstruction, ASIR-V-80%, and DLIR-H were 62.5% (666 of 1066 nodules), 73.3% (781 of 1066 nodules), and 75.8% (808 of 1066 nodules), respectively (P < .001). Bland-Altman analysis showed the percentage difference in long diameter from that of CECT was 9.3% (95% CI of the mean: 8.0, 10.6), 9.2% (95% CI of the mean: 8.0, 10.4), and 6.2% (95% CI of the mean: 5.0, 7.4) in FBP reconstruction, ASIR-V-80%, and DLIR-H, respectively (P < .001). Conclusion Compared with adaptive statistical iterative reconstruction-V, deep learning image reconstruction reduced image noise, increased nodule detection rate, and improved measurement accuracy on ultra-low-dose chest CT images. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Lee in this issue
    corecore