9,641 research outputs found

    Using quality models in software package selection

    Get PDF
    The growing importance of commercial off-the-shelf software packages requires adapting some software engineering practices, such as requirements elicitation and testing, to this emergent framework. Also, some specific new activities arise, among which selection of software packages plays a prominent role. All the methodologies that have been proposed recently for choosing software packages compare user requirements with the packages' capabilities. There are different types of requirements, such as managerial, political, and, of course, quality requirements. Quality requirements are often difficult to check. This is partly due to their nature, but there is another reason that can be mitigated, namely the lack of structured and widespread descriptions of package domains (that is, categories of software packages such as ERP systems, graphical or data structure libraries, and so on). This absence hampers the accurate description of software packages and the precise statement of quality requirements, and consequently overall package selection and confidence in the result of the process. Our methodology for building structured quality models helps solve this drawback.Peer ReviewedPostprint (published version

    Understanding the saturation power of Josephson Parametric Amplifiers made from SQUIDs arrays

    Full text link
    We report on the implementation and detailed modelling of a Josephson Parametric Amplifier (JPA) made from an array of eighty Superconducting QUantum Interference Devices (SQUIDs), forming a non-linear quarter-wave resonator. This device was fabricated using a very simple single step fabrication process. It shows a large bandwidth (45 MHz), an operating frequency tunable between 5.9 GHz and 6.8 GHz and a large input saturation power (-117 dBm) when biased to obtain 20 dB of gain. Despite the length of the SQUID array being comparable to the wavelength, we present a model based on an effective non-linear LC series resonator that quantitatively describes these figures of merit without fitting parameters. Our work illustrates the advantage of using array-based JPA since a single-SQUID device showing the same bandwidth and resonant frequency would display a saturation power 15 dB lower.Comment: 12 pages, 9 figures, Appendices include

    Nonlinear resonant behavior of the dispersive readout scheme for a superconducting flux qubit

    Full text link
    A nonlinear resonant circuit comprising a SQUID magnetometer and a parallel capacitor is studied as a readout scheme for a persistent-current (PC) qubit. The flux state of the qubit is detected as a change in the Josephson inductance of the SQUID magnetometer, which in turn mediates a shift in the resonance frequency of the readout circuit. The nonlinearity and resulting hysteresis in the resonant behavior are characterized as a function of the power of both the input drive and the associated resonance peak response. Numerical simulations based on a phenomenological circuit model are presented which display the features of the observed nonlinearity.Comment: 9 pages, 9 figure

    A nonlinear mechanism of charge qubit decoherence in a lossy cavity: the quasi normal mode approach

    Full text link
    In the viewpoint of quasi normal modes, we describe a novel decoherence mechanism of charge qubit of Josephson Junctions (JJ) in a lossy micro-cavity, which can appear in the realistic experiment for quantum computation based on JJ qubit. We show that the nonlinear coupling of a charge qubit to quantum cavity field can result in an additional dissipation of resonant mode due to its effective interaction between those non-resonant modes and a resonant mode, which is induced by the charge qubit itself. We calculate the characterized time of the novel decoherence by making use of the system plus bath method.Comment: 6 pages, 2 figur

    Testing collapse models with levitated nanoparticles: the detection challenge

    Get PDF
    We consider a nanoparticle levitated in a Paul trap in ultrahigh cryogenic vacuum, and look for the conditions which allow for a stringent noninterferometric test of spontaneous collapse models. In particular we compare different possible techniques to detect the particle motion. Key conditions which need to be achieved are extremely low residual pressure and the ability to detect the particle at ultralow power. We compare three different detection approaches based respectively on a optical cavity, optical tweezer and a electrical readout, and for each one we assess advantages, drawbacks and technical challenges

    Improving chronic disease prevention and screening in primary care: results of the BETTER pragmatic cluster randomized controlled trial.

    Get PDF
    BackgroundPrimary care provides most of the evidence-based chronic disease prevention and screening services offered by the healthcare system. However, there remains a gap between recommended preventive services and actual practice. This trial (the BETTER Trial) aimed to improve preventive care of heart disease, diabetes, colorectal, breast and cervical cancers, and relevant lifestyle factors through a practice facilitation intervention set in primary care.MethodsPragmatic two-way factorial cluster RCT with Primary Care Physicians' practices as the unit of allocation and individual patients as the unit of analysis. The setting was urban Primary Care Team practices in two Canadian provinces. Eight Primary Care Team practices were randomly assigned to receive the practice-level intervention or wait-list control; 4 physicians in each team (32 physicians) were randomly assigned to receive the patient-level intervention or wait-list control. Patients randomly selected from physicians' rosters were stratified into two groups: 1) general and 2) moderate mental illness. The interventions involved a multifaceted, evidence-based, tailored practice-level intervention with a Practice Facilitator, and a patient-level intervention involving a one-hour visit with a Prevention Practitioner where patients received a tailored 'prevention prescription'. The primary outcome was a composite Summary Quality Index of 28 evidence-based chronic disease prevention and screening actions with pre-defined targets, expressed as the ratio of eligible actions at baseline that were met at follow-up. A cost-effectiveness analysis was conducted.Results789 of 1,260 (63%) eligible patients participated. On average, patients were eligible for 8.96 (SD 3.2) actions at baseline. In the adjusted analysis, control patients met 23.1% (95% CI: 19.2% to 27.1%) of target actions, compared to 28.5% (95% CI: 20.9% to 36.0%) receiving the practice-level intervention, 55.6% (95% CI: 49.0% to 62.1%) receiving the patient-level intervention, and 58.9% (95% CI: 54.7% to 63.1%) receiving both practice- and patient-level interventions (patient-level intervention versus control, P < 0.001). The benefit of the patient-level intervention was seen in both strata. The extra cost of the intervention was 26.43CAN(9526.43CAN (95% CI: 16 to $44) per additional action met.ConclusionsA Prevention Practitioner can improve the implementation of clinically important prevention and screening for chronic diseases in a cost-effective manner

    Paramagnetic effect in YBaCuO grain boundary junctions

    Full text link
    A detailed investigation of the magnetic response of YBaCuO grain boundary Josephson junctions has been carried out using both radio-frequency measurements and Scanning SQUID Microscopy. In a nominally zero-field-cooled regime we observed a paramagnetic response at low external fields for 45 degree asymmetric grain boundaries. We argue that the observed phenomenology results from the d-wave order parameter symmetry and depends on Andreev bound states.Comment: To be published in Phys. Rev.

    Josephson effect in a CeCoIn5CeCoIn_5 microbridge

    Full text link
    We report DC Josephson effects observed in a microbridge prepared from an individual crystalline growth domain of CeCoIn5CeCoIn_5 thin film. Josephson effects were observed by periodic voltage modulations under external magnetic field ΔV(B)\Delta V(B) with the expected periodicity and by the temperature dependence of the Josephson critical current Ic(T)I_c(T). The shape of ΔV(B)\Delta V(B) was found to be asymmetric, as it is expected for microbridges. The dependence Ic(T)I_c(T) follows the Ambegaokar-Baratoff relation, which is unexpected for microbridges. Features in the dynamical resistance curves were attributed to the periodic motion of Abricosov vortices within the microbridge.Comment: 12 pages, 5 figures, submitted to Physica

    BICEP2 II: Experiment and Three-Year Data Set

    Full text link
    We report on the design and performance of the BICEP2 instrument and on its three-year data set. BICEP2 was designed to measure the polarization of the cosmic microwave background (CMB) on angular scales of 1 to 5 degrees (ℓ\ell=40-200), near the expected peak of the B-mode polarization signature of primordial gravitational waves from cosmic inflation. Measuring B-modes requires dramatic improvements in sensitivity combined with exquisite control of systematics. The BICEP2 telescope observed from the South Pole with a 26~cm aperture and cold, on-axis, refractive optics. BICEP2 also adopted a new detector design in which beam-defining slot antenna arrays couple to transition-edge sensor (TES) bolometers, all fabricated on a common substrate. The antenna-coupled TES detectors supported scalable fabrication and multiplexed readout that allowed BICEP2 to achieve a high detector count of 500 bolometers at 150 GHz, giving unprecedented sensitivity to B-modes at degree angular scales. After optimization of detector and readout parameters, BICEP2 achieved an instrument noise-equivalent temperature of 15.8 μ\muK sqrt(s). The full data set reached Stokes Q and U map depths of 87.2 nK in square-degree pixels (5.2 μ\muK arcmin) over an effective area of 384 square degrees within a 1000 square degree field. These are the deepest CMB polarization maps at degree angular scales to date. The power spectrum analysis presented in a companion paper has resulted in a significant detection of B-mode polarization at degree scales.Comment: 30 pages, 24 figure
    • …
    corecore