83 research outputs found

    Capsule endoscopy of the future: What's on the horizon?

    Get PDF
    Capsule endoscopes have evolved from passively moving diagnostic devices to actively moving systems with potential therapeutic capability. In this review, we will discuss the state of the art, define the current shortcomings of capsule endoscopy, and address research areas that aim to overcome said shortcomings. Developments in capsule mobility schemes are emphasized in this text, with magnetic actuation being the most promising endeavor. Research groups are working to integrate sensor data and fuse it with robotic control to outperform today's standard invasive procedures, but in a less intrusive manner. With recent advances in areas such as mobility, drug delivery, and therapeutics, we foresee a translation of interventional capsule technology from the bench-top to the clinical setting within the next 10 years

    Acoustic Sensing and Ultrasonic Drug Delivery in Multimodal Theranostic Capsule Endoscopy

    Get PDF
    Video capsule endoscopy (VCE) is now a clinically accepted diagnostic modality in which miniaturized technology, an on-board power supply and wireless telemetry stand as technological foundations for other capsule endoscopy (CE) devices. However, VCE does not provide therapeutic functionality, and research towards therapeutic CE (TCE) has been limited. In this paper, a route towards viable TCE is proposed, based on multiple CE devices including important acoustic sensing and drug delivery components. In this approach, an initial multimodal diagnostic device with high-frequency quantitative microultrasound that complements video imaging allows surface and subsurface visualization and computer-assisted diagnosis. Using focused ultrasound (US) to mark sites of pathology with exogenous fluorescent agents permits follow-up with another device to provide therapy. This is based on an US-mediated targeted drug delivery system with fluorescence imaging guidance. An additional device may then be utilized for treatment verification and monitoring, exploiting the minimally invasive nature of CE. While such a theranostic patient pathway for gastrointestinal treatment is presently incomplete, the description in this paper of previous research and work under way to realize further components for the proposed pathway suggests it is feasible and provides a framework around which to structure further work

    Small bowel capsule endoscopy : where are we after almost 15 years of use?

    Get PDF
    The development of capsule endoscopy (CE) in 2001 has given gastroenterologists the opportunity to investigate the small bowel in a non-invasive way. CE is most commonly performed for obscure gastrointestinal bleeding, but other indications include diagnosis or follow-up of Crohn's disease, suspicion of a small bowel tumor, diagnosis and surveillance of hereditary polyposis syndromes, Nonsteroidal anti-inflammatory drug-induced small bowel lesions and celiac disease. Almost fifteen years have passed since the release of the small bowel capsule. The purpose of this review is to offer the reader a brief but complete overview on small bowel CE anno 2014, including the technical and procedural aspects, the possible complications and the most important indications. We will end with some future perspectives of CE

    Magnetically Assisted Capsule Endoscopy: A Viable Alternative to Conventional Flexible Endoscopy of the Stomach?

    Get PDF
    INTRODUCTION: Oesophagogastroduodenoscopy is the investigation of choice to identify mucosal lesions of the upper gastrointestinal tract, but it is poorly tolerated by patients. A simple non-invasive technique to image the upper gastrointestinal tract, which could be made widely available, would be beneficial to patients. Capsule endoscopy is well tolerated by patients but the stomach has proved difficult to visualise accurately with capsule technology due to its’ capacious nature and mucosal folds, which can obscure pathology. MiroCam Navi (Intromedic Ltd, Seoul, Korea) is a capsule endoscope containing a small amount of magnetic material which has been made available with a handheld magnet which might allow a degree of control. This body of work aims to address whether this new technology could be a feasible alternative to conventional flexible endoscopy of the stomach. METHODS: Four studies were conducted to test this research question. The first explores the feasibility of magnetically assisted capsule endoscopy of the stomach and operator learning curve in an ex vivo porcine model. This was followed by a randomised, blinded trial comparing magnetically assisted capsule endoscopy to conventional flexible endoscopy in ex vivo porcine stomach models. Subsequently a prospective, single centre randomised controlled trial in humans examined whether magnetically assisted capsule endoscopy could enhance conventional small bowel capsule endoscopy by reducing gastric transit time. Finally a blinded comparison of diagnostic yield of magnetically assisted capsule endoscopy compared to oesophagogastroduodenoscopy was performed in patients with recurrent or refractory iron deficiency anaemia. RESULTS: In the first study all stomach tags were identified in 87.2% of examinations and a learning curve was demonstrated (mean examination times for the first 23 and second 23 procedures 10.28 and 6.26 minutes respectively (p<0.001). In the second study the difference in sensitivities between oesophagogastroduodenoscopy and conventional flexible endoscopy for detecting beads within an ex vivo porcine stomach model was 1.11 (95% CI 0.06, 28.26) proving magnetically assisted capsule endoscopy to be non-inferior to flexible endoscopy. In the first human study, although there was no significant difference in gastric transit time or capsule endoscopy completion rate between the two groups (p=0.12 and p=0.39 respectively), the time to first pyloric image was significantly shorter in the intervention group (p=0.03) suggesting that magnetic control hastens capsular transit to the gastric antrum but cannot impact upon duodenal passage. In the last study, a total of 38 pathological findings were identified in this comparative study of magnetically assisted capsule endoscopy and conventional endoscopy. Of these, 16 were detected at both procedures, while flexible endoscopy identified 14 additional lesions not seen at magnetically assisted capsule endoscopy and magnetically assisted capsule endoscopy detected 8 abnormalities not seen by oesophagogastroduodenoscopy. No adverse events occurred in either of the human trials. Finally magnetically steerable capsule endoscopy induced less procedural pain, discomfort and distress than oesophagogastroduodenoscopy (p=0.0009, p=0.001 and p=0.006 respectively). CONCLUSION: Magnetically assisted capsule endoscopy is safe, well tolerated and a viable alternative to conventional endoscopy. Further research to develop and improve this new procedure is recommended

    New Techniques in Gastrointestinal Endoscopy

    Get PDF
    As result of progress, endoscopy has became more complex, using more sophisticated devices and has claimed a special form. In this moment, the gastroenterologist performing endoscopy has to be an expert in macroscopic view of the lesions in the gut, with good skills for using standard endoscopes, with good experience in ultrasound (for performing endoscopic ultrasound), with pathology experience for confocal examination. It is compulsory to get experience and to have patience and attention for the follow-up of thousands of images transmitted during capsule endoscopy or to have knowledge in physics necessary for autofluorescence imaging endoscopy. Therefore, the idea of an endoscopist has changed. Examinations mentioned need a special formation, a superior level of instruction, accessible to those who have already gained enough experience in basic diagnostic endoscopy. This is the reason for what these new issues of endoscopy are presented in this book of New techniques in Gastrointestinal Endoscopy

    LOCAL CONTROL ROBOTIC SURGICAL DEVICES AND RELATED METHODS

    Get PDF
    The various robotic medical devices include robotic devices that are disposed within a body cavity and positioned using a support component disposed through an orifice or opening in the body cavity. Additional embodiments relate to devices having arms coupled to a device body wherein the device has a minimal profile such that the device can be easily inserted through smaller incisions in comparison to other devices without such a small profile. Further embodiments relate to methods of operating the above devices

    LOCAL CONTROL ROBOTIC SURGICAL DEVICES AND RELATED METHODS

    Get PDF
    The various robotic medical devices include robotic devices that are disposed within a body cavity and positioned using a support component disposed through an orifice or opening in the body cavity. Additional embodiments relate to devices having arms coupled to a device body wherein the device has a minimal profile such that the device can be easily inserted through smaller incisions in comparison to other devices without such a small profile. Further embodiments relate to methods of operating the above devices

    Conformal antenna-based wireless telemetry system for capsule endoscopy

    Get PDF
    Capsule endoscopy for imaging the gastrointestinal tract is an innovative tool for carrying out medical diagnosis and therapy. Additional modalities beyond optical imaging would enhance current capabilities at the expense of denser integration, due to the limited space available within the capsule. We therefore need new designs and technologies to increase the smartness of the capsules for a given volume. This thesis presents the design, manufacture and performance characterisation of a helical antenna placed conformally outside an endoscopic capsule, and the characterisation in-silico, in-vitro and in-vivo of the telemetry system in alive and euthanised pigs. This method does not use the internal volume of the capsule, but does use an extra coating to protect the antenna from the surrounding tissue and maintain biocompatibility for safe use inside the human body. The helical antenna, radiating at 433 MHz with a bandwidth of 20 MHz within a muscle-type tissue, presents a low gain and efficiency, which is typical for implantable and ingestible medical devices. Telemetry capsule prototypes were simulated, manufactured and assembled with the necessary internal electronics, including a commercially available transceiver unit. Thermistors were embedded into each capsule shell, to record any temperature increase in the tissue surrounding the antenna during the experiments. A temperature increase of less than 1°C was detected for the tissue surrounding the antenna. The process of coating the biocompatible insulation layer over the full length of the capsule is described in detail. Data transmission programmes were established to send programmed data packets to an external receiver. The prototypes radiated at different power levels ranging from -10 to 10 dBm, and all capsules demonstrated a satisfactory performance at a data rate of 16 kbps during phantom and in-vivo experiments. Data transmission was achieved with low bit-error rates below 10-5. A low signal strength of only -54 dBm still provided effective data transfer, irrespective of the orientation and location of the capsule, and this successfully demonstrated the feasibility of the system
    • …
    corecore