11,008 research outputs found

    Review of sensors for remote patient monitoring

    Get PDF
    Remote patient monitoring (RPM) of physiological measurements can provide an efficient method and high quality care to patients. The physiological signals measurement is the initial and the most important factor in RPM. This paper discusses the characteristics of the most popular sensors, which are used to obtain vital clinical signals in prevalent RPM systems. The sensors discussed in this paper are used to measure ECG, heart sound, pulse rate, oxygen saturation, blood pressure and respiration rate, which are treated as the most important vital data in patient monitoring and medical examination

    Multimodal optical diagnostics of the microhaemodynamics in upper and lower limbs

    Get PDF
    The introduction of optical non-invasive diagnostic methods into clinical practice can substantially advance in the detection of early microcirculatory disorders in patients with different diseases. This paper is devoted to the development and application of the optical non-invasive diagnostic approach for the detection and evaluation of the severity of microcirculatory and metabolic disorders in rheumatic diseases and diabetes mellitus. The proposed methods include the joint use of laser Doppler flowmetry, absorption spectroscopy and fluorescence spectroscopy in combination with functional tests. This technique showed the high diagnostic importance for the detection of disturbances in peripheral microhaemodynamics. These methods have been successfully tested as additional diagnostic techniques in the field of rheumatology and endocrinology. The sensitivity and specificity of the proposed diagnostic procedures have been evaluated.<br/

    NIH Workshop 2018: Towards Minimally-invasive or Non-invasive Approaches to Assess Tissue Oxygenation Pre- and Post-Transfusion

    Get PDF
    Because blood transfusion is one of the most common therapeutic interventions in hospitalized patients, much recent research has focused on improving the storage quality in vitro of donor red blood cells (RBCs) that are then used for transfusion. However, there is a significant need for enhancing our understanding of the efficacy of the transfused RBCs in vivo. To this end, the NIH sponsored a one-and-a-half-day workshop that brought together experts in multiple disciplines relevant to tissue oxygenation (e.g., transfusion medicine, critical care medicine, cardiology, neurology, neonatology and pediatrics, bioengineering, biochemistry, and imaging). These individuals presented their latest findings, discussed key challenges, and aimed to construct recommendations for facilitating development of new technologies and/or biomarker panels to assess tissue oxygenation in a minimally-invasive to non-invasive fashion, before and after RBC transfusion. The workshop was structured into four sessions: (1) Global Perspective; (2) Organ Systems; (3) Neonatology; and (4) Emerging Technologies. The first day provided an overview of current approaches in the clinical setting, both from a global perspective, including the use of metabolomics for studying RBCs and tissue perfusion, and from a more focused perspective, including tissue oxygenation assessments in neonates and in specific adult organ systems. The second day focused on emerging technologies, which could be applied pre- and post-RBC transfusion, to assess tissue oxygenation in minimally-invasive or non-invasive ways. Each day concluded with an open-microphone discussion among the speakers and workshop participants. The workshop presentations and ensuing interdisciplinary discussions highlighted the potential of technologies to combine global “omics” signatures with additional measures (e.g., thenar eminence measurements or various imaging methods) to predict which patients could potentially benefit from a RBC transfusion and whether the ensuing RBC transfusion was effective. The discussions highlighted the need for collaborations across the various disciplines represented at the meeting to leverage existing technologies and to develop novel approaches for assessing RBC transfusion efficacy in various clinical settings. Although the Workshop took place in April, 2018, the concepts described and the ensuing discussions were, perhaps, even more relevant in April, 2020, at the time of writing this manuscript, during the explosive growth of the COVID-19 pandemic in the United States. Thus, issues relating to maintaining and improving tissue oxygenation and perfusion are especially pertinent because of the extensive pulmonary damage resulting from SARS-CoV-2 infection [1], compromises in perfusion caused by thrombotic-embolic phenomena [2], and damage to circulating RBCs, potentially compromising their oxygen-carrying capacity [3]. The severe end organ effects of SARS-CoV-2 infection mandate even more urgency for improving our understanding of tissue perfusion and oxygenation, improve methods for measuring and monitoring them, and develop novel ways of enhancing them

    NIH Workshop 2018: Towards Minimally Invasive or Noninvasive Approaches to Assess Tissue Oxygenation Pre- and Post-transfusion

    Get PDF
    Because blood transfusion is one of the most common therapeutic interventions in hospitalized patients, much recent research has focused on improving the storage quality in vitro of donor red blood cells (RBCs) that are then used for transfusion. However, there is a significant need for enhancing our understanding of the efficacy of the transfused RBCs in vivo. To this end, the NIH sponsored a one-and-a-half-day workshop that brought together experts in multiple disciplines relevant to tissue oxygenation (eg, transfusion medicine, critical care medicine, cardiology, neurology, neonatology and pediatrics, bioengineering, biochemistry, and imaging). These individuals presented their latest findings, discussed key challenges, and aimed to identify opportunities for facilitating development of new technologies and/or biomarker panels to assess tissue oxygenation in a minimally-invasive to non-invasive fashion, before and after RBC transfusion

    The Challenges of O2 Detection in Biological Fluids: Classical Methods and Translation to Clinical Applications

    Get PDF
    Dissolved oxygen (DO) is deeply involved in preserving the life of cellular tissues and human beings due to its key role in cellular metabolism: its alterations may reflect important pathophysiological conditions. DO levels are measured to identify pathological conditions, explain pathophysiological mechanisms, and monitor the efficacy of therapeutic approaches. This is particularly relevant when the measurements are performed in vivo but also in contexts where a variety of biological and synthetic media are used, such as ex vivo organ perfusion. A reliable measurement of medium oxygenation ensures a high-quality process. It is crucial to provide a high-accuracy, real-time method for DO quantification, which could be robust towards different medium compositions and temperatures. In fact, biological fluids and synthetic clinical fluids represent a challenging environment where DO interacts with various compounds and can change continuously and dynamically, and further precaution is needed to obtain reliable results. This study aims to present and discuss the main oxygen detection and quantification methods, focusing on the technical needs for their translation to clinical practice. Firstly, we resumed all the main methodologies and advancements concerning dissolved oxygen determination. After identifying the main groups of all the available techniques for DO sensing based on their mechanisms and applicability, we focused on transferring the most promising approaches to a clinical in vivo/ex vivo settin

    Development, Design, and Utilization of a Reflective Based Photoplethysmography Sensor

    Get PDF
    Plethysmography refers to the dynamic measurement of biological tissue volumes that, for example, may change due to fluctuations in blood volume. Photoplethysmography (PPG) makes use of the attenuation of light penetrating into vascular tissues to determine these changes in blood volume. Modern PPG is an optical technique involving low cost photosensors and light emitting diodes (LED), and is capable of measuring multiple biological vitals simultaneously. For example, in addition to heart rate determination, PPG devices can be used as pulse oximeters, capable of calculating the blood oxygen saturation (SpO2) through a series of simple optical calculations performed on either reflectance or transmittance data. In this project, a reflectance-based PPG pulse oximeter was designed to collect blood volume measurements on the foot of a patient. This project also involves using the PPG sensor to determine the effect of vibrational signal on vasoconstriction in the tissue, to provide more information on biological properties, including diabetic nerve damage. The device is constructed via dual wavelength light sources and a phototransistor where the light sources are determined based on the isosbestic point, for oxygenated and deoxygenated hemoglobin

    Tissue hemoglobin index: a non-invasive optical measure of total tissue hemoglobin

    Get PDF
    Introduction: The tissue hemoglobin index (THI) is a hemoglobin signal strength metric provided on the InSpectra ™ StO2 Tissue Oxygenation Monitor, Model 650. There is growing interest regarding the physiologic meaning of THI and whether a clinically useful correlation between THI and blood hemoglobin concentratio

    Enhanced monitoring of the preterm infant during stabilization in the delivery room

    Get PDF
    Monitoring of preterm infants in the delivery room (DR) remains limited. Current guidelines suggest that pulse oximetry should be available for all preterm infant deliveries, and that if intubated a colorimetric carbon dioxide detector should provide verification of correct endotracheal tube placement. These two methods of assessment represent the extent of objective monitoring of the newborn commonly performed in the DR. Monitoring non-invasive ventilation effectiveness (either by capnography or respiratory function monitoring) and cerebral oxygenation (near-infrared spectroscopy) is becoming more common within research settings. In this article, we will review the different modalities available for cardiorespiratory and neuromonitoring in the DR and assess the current evidence base on their feasibility, strengths, and limitations during preterm stabilization
    corecore