Advanced H-1 Lung Magnetic Resonance Imaging
Magnetic resonance imaging (MRI) is one of the widely used medical imaging modality, since it can provide both structural and functional assessment in a single imaging session. However, two major challenges should be considered by using MRI for lung imaging. The first challenge is the intrinsic low SNR of H-1 lung MRI due to the low proton density as well as the fast decay of the lung parenchyma signal. And the second challenge is subject motion. To achieve high resolution structural image, MRI requires a long scan time, usually a few minutes or even longer, which make MRI sensitive to subject motion. To address the first challenge, ultra-short echo time (UTE) MRI sequence is used to capture the lung parenchyma signal before decay. As for subject motion, two major strategies are widely used. One strategy is fast breath-holding scan, the subjects are asked to hold their breaths for a short duration, and the fast 3D MR sequence would be used to acquire data within that duration. This dissertation proposes a new acquisition scheme based on the standard UTE sequence, which largely increases the encoding efficiency and improves the breath-holding scan images. The other is free breathing scan with motion correction. The subjects are allowed to breathe during the MR acquisition. After the acquisition, the motion corrupted data would go through the motion correction step to reconstruct the motion free images. In this dissertation, two novel motion corrected reconstruction strategies are proposed to incorporate the motion modeling and compensation into the reconstruction to get high SNR motion corrected 3D and 4D images. When translating the developed techniques to the clinical studies, specifically for pediatric and neonatal studies, more practical problems need to be considered, such as smaller but finer anatomy to image, the different respiratory patterns of the young subjects etc. This dissertation proposes a 5-minute free breathing UTE MRI strategy to achieve a 3D high resolution motion free lung image for pediatric and neonatal studies
Super-Resolution in Respiratory Synchronized Positron Emission Tomography
Respiratory motion is a major source of reduced quality in positron emission tomography (PET). In order to minimize its effects, the use of respiratory synchronized acquisitions, leading to gated frames, has been suggested. Such frames, however, are of low signal-to-noise ratio (SNR) as they contain reduced statistics. Super-resolution (SR) techniques make use of the motion in a sequence of images in order to improve their quality. They aim at enhancing a low-resolution image belonging to a sequence of images representing different views of the same scene. In this work, a maximum a posteriori (MAP) super-resolution algorithm has been implemented and applied to respiratory gated PET images for motion compensation. An edge preserving Huber regularization term was used to ensure convergence. Motion fields were recovered using a B-spline based elastic registration algorithm. The performance of the SR algorithm was evaluated through the use of both simulated and clinical datasets by assessing image SNR, as well as the contrast, position and extent of the different lesions. Results were compared to summing the registered synchronized frames on both simulated and clinical datasets. The super-resolution image had higher SNR (by a factor of over 4 on average) and lesion contrast (by a factor of 2) than the single respiratory synchronized frame using the same reconstruction matrix size. In comparison to the motion corrected or the motion free images a similar SNR was obtained, while improvements of up to 20% in the recovered lesion size and contrast were measured. Finally, the recovered lesion locations on the SR images were systematically closer to the true simulated lesion positions. These observations concerning the SNR, lesion contrast and size were confirmed on two clinical datasets included in the study. In conclusion, the use of SR techniques applied to respiratory motion synchronized images lead to motion compensation combined with improved image SNR and contrast, without any increase in the overall acquisition times
Improving the Accuracy of CT-derived Attenuation Correction in Respiratory-Gated PET/CT Imaging
The effect of respiratory motion on attenuation correction in Fludeoxyglucose (18F) positron emission tomography (FDG-PET) was investigated. Improvements to the accuracy of computed tomography (CT) derived attenuation correction were obtained through the alignment of the attenuation map to each emission image in a respiratory gated PET scan. Attenuation misalignment leads to artefacts in the reconstructed PET image and several methods were devised for evaluating the attenuation inaccuracies caused by this. These methods of evaluation were extended to finding the frame in the respiratory gated PET which best matched the CT. This frame was then used as a reference frame in mono-modality compensation for misalignment. Attenuation correction was found to affect the quantification of tumour volumes; thus a regional analysis was used to evaluate the impact of mismatch and the benefits of compensating for misalignment. Deformable image registration was used to compensate for misalignment, however, there were inaccuracies caused by the poor signal-to-noise ratio (SNR) in PET images. Two models were developed that were robust to a poor SNR allowing for the estimation of deformation from very noisy images. Firstly, a cross population model was developed by statistically analysing the respiratory motion in 10 4DCT scans. Secondly, a 1D model of respiration was developed based on the physiological function of respiration. The 1D approach correctly modelled the expansion and contraction of the lungs and the differences in the compressibility of lungs and surrounding tissues. Several additional models were considered but were ruled out based on their poor goodness of fit to 4DCT scans. Approaches to evaluating the developed models were also used to assist with optimising for the most accurate attenuation correction. It was found that the multimodality registration of the CT image to the PET image was the most accurate approach to compensating for attenuation correction mismatch. Mono-modality image registration was found to be the least accurate approach, however, incorporating a motion model improved the accuracy of image registration. The significance of these findings is twofold. Firstly, it was found that motion models are required to improve the accuracy in compensating for attenuation correction mismatch and secondly, a validation method was found for comparing approaches to compensating for attenuation mismatch
Improving the Accuracy of CT-derived Attenuation Correction in Respiratory-Gated PET/CT Imaging
The effect of respiratory motion on attenuation correction in Fludeoxyglucose (18F) positron emission tomography (FDG-PET) was investigated. Improvements to the accuracy of computed tomography (CT) derived attenuation correction were obtained through the alignment of the attenuation map to each emission image in a respiratory gated PET scan. Attenuation misalignment leads to artefacts in the reconstructed PET image and several methods were devised for evaluating the attenuation inaccuracies caused by this. These methods of evaluation were extended to finding the frame in the respiratory gated PET which best matched the CT. This frame was then used as a reference frame in mono-modality compensation for misalignment. Attenuation correction was found to affect the quantification of tumour volumes; thus a regional analysis was used to evaluate the impact of mismatch and the benefits of compensating for misalignment. Deformable image registration was used to compensate for misalignment, however, there were inaccuracies caused by the poor signal-to-noise ratio (SNR) in PET images. Two models were developed that were robust to a poor SNR allowing for the estimation of deformation from very noisy images. Firstly, a cross population model was developed by statistically analysing the respiratory motion in 10 4DCT scans. Secondly, a 1D model of respiration was developed based on the physiological function of respiration. The 1D approach correctly modelled the expansion and contraction of the lungs and the differences in the compressibility of lungs and surrounding tissues. Several additional models were considered but were ruled out based on their poor goodness of fit to 4DCT scans. Approaches to evaluating the developed models were also used to assist with optimising for the most accurate attenuation correction. It was found that the multimodality registration of the CT image to the PET image was the most accurate approach to compensating for attenuation correction mismatch. Mono-modality image registration was found to be the least accurate approach, however, incorporating a motion model improved the accuracy of image registration. The significance of these findings is twofold. Firstly, it was found that motion models are required to improve the accuracy in compensating for attenuation correction mismatch and secondly, a validation method was found for comparing approaches to compensating for attenuation mismatch
A Novel Prior- and Motion-Based Compressed Sensing Method for Small-Animal Respiratory Gated CT
Low-dose protocols for respiratory gating in cardiothoracic small-animal imaging lead to streak artifacts in the images reconstructed with a Feldkamp-Davis-Kress (FDK) method. We propose a novel prior-and motion-based reconstruction (PRIMOR) method, which improves prior-based reconstruction (PBR) by adding a penalty function that includes a model of motion. The prior image is generated as the average of all the respiratory gates, reconstructed with FDK. Motion between respiratory gates is estimated using a nonrigid registration method based on hierarchical B-splines. We compare PRIMOR with an equivalent PBR method without motion estimation using as reference the reconstruction of high dose data. From these data acquired with a micro-CT scanner, different scenarios were simulated by changing photon flux and number of projections. Methods were evaluated in terms of contrast-to-noise-ratio (CNR), mean square error (MSE), streak artefact indicator (SAI), solution error norm (SEN), and correction of respiratory motion. Also, to evaluate the effect of each method on lung studies quantification, we have computed the Jaccard similarity index of the mask obtained from segmenting each image as compared to those obtained from the high dose reconstruction. Both iterative methods greatly improved FDK reconstruction in all cases. PBR was prone to streak artifacts and presented blurring effects in bone and lung tissues when using both a low number of projections and low dose. Adopting PBR as a reference, PRIMOR increased CNR up to 33% and decreased MSE, SAI and SEN up to 20%, 4% and 13%, respectively. PRIMOR also presented better compensation for respiratory motion and higher Jaccard similarity index. In conclusion, the new method proposed for low-dose respiratory gating in small-animal scanners shows an improvement in image quality and allows a reduction of dose or a reduction of the number of projections between two and three times with respect to previous PBR approaches.This work was funded by the Spanish Ministerio de EconomĂa y Competitividad (www.mineco.gob.es/) with projects IDI-20130301, TEC2013-47270-R, IPT-2012-0401-300000, RTC-2014-3028-1, and RD12/0042/0057. Also, the research leading to these results has received funding from the Innovative Medicines Initiative (www.imi.europa.eu) Joint Undertaking under grant agreement n°115337, resources of which are composed of financial contribution from the European Union's Seventh Framework Programme (FP7/2007-2013) and EFPIA companies' in kind contribution. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.Publicad
Spatiotemporal PET reconstruction using ML-EM with learned diffeomorphic deformation
Patient movement in emission tomography deteriorates reconstruction quality
because of motion blur. Gating the data improves the situation somewhat: each
gate contains a movement phase which is approximately stationary. A standard
method is to use only the data from a few gates, with little movement between
them. However, the corresponding loss of data entails an increase of noise.
Motion correction algorithms have been implemented to take into account all the
gated data, but they do not scale well, especially not in 3D. We propose a
novel motion correction algorithm which addresses the scalability issue. Our
approach is to combine an enhanced ML-EM algorithm with deep learning based
movement registration. The training is unsupervised, and with artificial data.
We expect this approach to scale very well to higher resolutions and to 3D, as
the overall cost of our algorithm is only marginally greater than that of a
standard ML-EM algorithm. We show that we can significantly decrease the noise
corresponding to a limited number of gates
- âŠ