    Using Signal Processing Techniques to Detect Sleep Apnea Events

    Get PDF
    Nowadays, with the development of modern technology, we can detect sleep apnea by using Electroencephalography (EEG), Electrocardiography (ECG), blood pressure (BP), and Respiration rates (RR). These signals are recorded in time domain, however for us to extract vital information we must analyze them in frequency domain. This research will examine sleep apnea; how to understand it and in doing so determine the best methods of detection using several different signal processing techniques. By doing so we hope to help physicians further improve their detection methods as well as their accuracy

    Sleep apnea-hypopnea quantification by cardiovascular data analysis

    Get PDF
    Sleep apnea is the most common sleep disturbance and it is an important risk factor for cardiovascular disorders. Its detection relies on a polysomnography, a combination of diverse exams. In order to detect changes due to sleep disturbances such as sleep apnea occurrences, without the need of combined recordings, we mainly analyze systolic blood pressure signals (maximal blood pressure value of each beat to beat interval). Nonstationarities in the data are uncovered by a segmentation procedure, which provides local quantities that are correlated to apnea-hypopnea events. Those quantities are the average length and average variance of stationary patches. By comparing them to an apnea score previously obtained by polysomnographic exams, we propose an apnea quantifier based on blood pressure signal. This furnishes an alternative procedure for the detection of apnea based on a single time series, with an accuracy of 82%

    Screening of Obstructive Sleep Apnea with Empirical Mode Decomposition of Pulse Oximetry

    Full text link
    Detection of desaturations on the pulse oximetry signal is of great importance for the diagnosis of sleep apneas. Using the counting of desaturations, an index can be built to help in the diagnosis of severe cases of obstructive sleep apnea-hypopnea syndrome. It is important to have automatic detection methods that allows the screening for this syndrome, reducing the need of the expensive polysomnography based studies. In this paper a novel recognition method based on the empirical mode decomposition of the pulse oximetry signal is proposed. The desaturations produce a very specific wave pattern that is extracted in the modes of the decomposition. Using this information, a detector based on properly selected thresholds and a set of simple rules is built. The oxygen desaturation index constructed from these detections produces a detector for obstructive sleep apnea-hypopnea syndrome with high sensitivity (0.8380.838) and specificity (0.8550.855) and yields better results than standard desaturation detection approaches.Comment: Accepted in Medical Engineering and Physic

    Non-linear HRV analysis to quantify the effects of intermittent hypoxia using an OSA rat model

    Get PDF
    © 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting /republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other worksIn this paper, a non-linear HRV analysis was performed to assess fragmentation signatures observed in heartbeat time series after intermittent hypoxia (IH). Three markers quantifying short-term fragmentation levels, PIP, IALS and PSS, were evaluated on R-R interval series obtained in a rat model of recurrent apnea. Through airway obstructions, apnea episodes were periodically simulated in six anesthetized Sprague-Dawley rats. The number of apnea events per hour (AHI index) was varied during the first half of the experiment while apnea episodes lasted 15 s. For the second part, apnea episodes lasted 5, 10 or 15 s, but the AHI index was fixed. Recurrent apnea was repeated for 15-min time intervals in all cases, alternating with basal periods of the same duration. The fragmentation markers were evaluated in segments of 5 minutes, selected at the beginning and end of the experiment. The impact of the heart and breathing rates (HR and BR, respectively) on the parameter estimates was also investigated. The results obtained show a significant increase (from 5 to 10%, p 0.9) between these markers and BR, as well as with the ratio given by HR/BR. Although fragmentation may be impacted by IH, we found that it is highly dependent on HR and BR values and thus, they should be considered during its calculation or used to normalize the fragmentation estimatesPeer ReviewedPostprint (published version

    Functional Imaging of Autonomic Regulation: Methods and Key Findings.

    Get PDF
    Central nervous system processing of autonomic function involves a network of regions throughout the brain which can be visualized and measured with neuroimaging techniques, notably functional magnetic resonance imaging (fMRI). The development of fMRI procedures has both confirmed and extended earlier findings from animal models, and human stroke and lesion studies. Assessments with fMRI can elucidate interactions between different central sites in regulating normal autonomic patterning, and demonstrate how disturbed systems can interact to produce aberrant regulation during autonomic challenges. Understanding autonomic dysfunction in various illnesses reveals mechanisms that potentially lead to interventions in the impairments. The objectives here are to: (1) describe the fMRI neuroimaging methodology for assessment of autonomic neural control, (2) outline the widespread, lateralized distribution of function in autonomic sites in the normal brain which includes structures from the neocortex through the medulla and cerebellum, (3) illustrate the importance of the time course of neural changes when coordinating responses, and how those patterns are impacted in conditions of sleep-disordered breathing, and (4) highlight opportunities for future research studies with emerging methodologies. Methodological considerations specific to autonomic testing include timing of challenges relative to the underlying fMRI signal, spatial resolution sufficient to identify autonomic brainstem nuclei, blood pressure, and blood oxygenation influences on the fMRI signal, and the sustained timing, often measured in minutes of challenge periods and recovery. Key findings include the lateralized nature of autonomic organization, which is reminiscent of asymmetric motor, sensory, and language pathways. Testing brain function during autonomic challenges demonstrate closely-integrated timing of responses in connected brain areas during autonomic challenges, and the involvement with brain regions mediating postural and motoric actions, including respiration, and cardiac output. The study of pathological processes associated with autonomic disruption shows susceptibilities of different brain structures to altered timing of neural function, notably in sleep disordered breathing, such as obstructive sleep apnea and congenital central hypoventilation syndrome. The cerebellum, in particular, serves coordination roles for vestibular stimuli and blood pressure changes, and shows both injury and substantially altered timing of responses to pressor challenges in sleep-disordered breathing conditions. The insights into central autonomic processing provided by neuroimaging have assisted understanding of such regulation, and may lead to new treatment options for conditions with disrupted autonomic function

    Protocol of the SOMNIA project : an observational study to create a neurophysiological database for advanced clinical sleep monitoring

    Get PDF
    Introduction Polysomnography (PSG) is the primary tool for sleep monitoring and the diagnosis of sleep disorders. Recent advances in signal analysis make it possible to reveal more information from this rich data source. Furthermore, many innovative sleep monitoring techniques are being developed that are less obtrusive, easier to use over long time periods and in the home situation. Here, we describe the methods of the Sleep and Obstructive Sleep Apnoea Monitoring with Non-Invasive Applications (SOMNIA) project, yielding a database combining clinical PSG with advanced unobtrusive sleep monitoring modalities in a large cohort of patients with various sleep disorders. The SOMNIA database will facilitate the validation and assessment of the diagnostic value of the new techniques, as well as the development of additional indices and biomarkers derived from new and/or traditional sleep monitoring methods. Methods and analysis We aim to include at least 2100 subjects (both adults and children) with a variety of sleep disorders who undergo a PSG as part of standard clinical care in a dedicated sleep centre. Full-video PSG will be performed according to the standards of the American Academy of Sleep Medicine. Each recording will be supplemented with one or more new monitoring systems, including wrist-worn photoplethysmography and actigraphy, pressure sensing mattresses, multimicrophone recording of respiratory sounds including snoring, suprasternal pressure monitoring and multielectrode electromyography of the diaphragm

    A comparative study of four novel sleep apnoea episode prediction systems

    Get PDF
    The prediction of sleep apnoea and hypopnoea episodes could allow treatment to be applied before the event be-comes detrimental to the patients sleep, and for a more spe-cific form of treatment. It is proposed that features extracted from breaths preceding an apnoea and hypopnoea could be used in neural networks for the prediction of these events. Four different predictive systems were created, processing the nasal airflow signal using epoching, the inspiratory peak and expiratory trough values, principal component analysis (PCA) and empirical mode decomposition (EMD). The neu-ral networks were validated with naïve data from six over-night polysomnographic records, resulting in 83.50% sensi-tivity and 90.50% specificity. Reliable prediction of apnoea and hypopnoea is possible using the epoched flow and EMD of breaths preceding the event