    Overview of three-phase inverter topologies for distributed generation purposes

    Get PDF
    The increasing presence of single-phase distributed generators and unbalanced loads in the electric power system may lead to unbalance of the three phase voltages, resulting in increased losses and heating. Distribution network operators are seeking to install larger DG units (viz. >5>5kVA in Belgium) by means of three-phase connections instead of single-phase to reduce voltage unbalance. There are several possible topologies to connect the DG units to the three-phase distribution network. These topologies can be divided into three groups: the three-phase three-wire inverters, the three-phase four-wire inverters and the multilevel inverters. In this paper, an overview of the aforementioned topologies is given

    Multilevel Converters: An Enabling Technology for High-Power Applications

    Get PDF
    | Multilevel converters are considered today as the state-of-the-art power-conversion systems for high-power and power-quality demanding applications. This paper presents a tutorial on this technology, covering the operating principle and the different power circuit topologies, modulation methods, technical issues and industry applications. Special attention is given to established technology already found in industry with more in-depth and self-contained information, while recent advances and state-of-the-art contributions are addressed with useful references. This paper serves as an introduction to the subject for the not-familiarized reader, as well as an update or reference for academics and practicing engineers working in the field of industrial and power electronics.Ministerio de Ciencia y Tecnología DPI2001-3089Ministerio de Eduación y Ciencia d TEC2006-0386

    Power Quality Improvement Wind Energy System Using Cascaded Multilevel Inverter

    No full text
    In this paper, a wind energy conversion system based on a cascaded H-bridge multilevel inverter (CHBMLI) topology has been proposed to be used for the grid interface of large split winding alternators (SWAs). A new method has been suggested for the generation of reference currents for the voltage source inverter (VSI) depending upon the available wind power. The CHBMLI has been used as a VSI and operated in a current control mode order to achieve the objectives of real power injection and load compensation (power factor correction, load balancing, and harmonic compensation) based on the proposed reference generation scheme. In the field excitation control of SWA provides a single means vary the dc link voltages of all the CHBs simultaneously and proportionatel

    Power Quality Enhancement in Electricity Grids with Wind Energy Using Multicell Converters and Energy Storage

    Get PDF
    In recent years, the wind power industry is experiencing a rapid growth and more wind farms with larger size wind turbines are being connected to the power system. While this contributes to the overall security of electricity supply, large-scale deployment of wind energy into the grid also presents many technical challenges. Most of these challenges are one way or another, related to the variability and intermittent nature of wind and affect the power quality of the distribution grid. Power quality relates to factors that cause variations in the voltage level and frequency as well as distortion in the voltage and current waveforms due to wind variability which produces both harmonics and inter-harmonics. The main motivation behind work is to propose a new topology of the static AC/DC/AC multicell converter to improve the power quality in grid-connected wind energy conversion systems. Serial switching cells have the ability to achieve a high power with lower-size components and improve the voltage waveforms at the input and output of the converter by increasing the number of cells. Furthermore, a battery energy storage system is included and a power management strategy is designed to ensure the continuity of power supply and consequently the autonomy of the proposed system. The simulation results are presented for a 149.2 kW wind turbine induction generator system and the results obtained demonstrate the reduced harmonics, improved transient response, and reference tracking of the voltage output of the wind energy conversion system.Peer reviewedFinal Accepted Versio

    Multilevel Converter Topologies for Utility Scale Solar Photovoltaic Power Systems

    Get PDF
    Renewable energy technologies have been growing in their installed capacity rapidly over the past few years. This growth in solar, wind and other technologies is fueled by state incentives, renewable energy mandates, increased fossil fuel prices and environmental consciousness. Utility scale systems form a substantial portion of electricity capacity addition in modern times. This sets the stage for research activity to explore new efficient, compact and alternative power electronic topologies to integrate sources like photovoltaics (PV) to the utility grid, some of which are multilevel topologies. Multilevel topologies allow for use of lower voltage semiconductor devices than two-level converters. They also produce lower distortion output voltage waveforms. This dissertation proposes a cascaded multilevel converter with medium frequency AC link which reduces the size of DC bus capacitor and also eliminates power imbalance between the three phases. A control strategy which modulates the output voltage magnitude and phase angle of the inverter cells is proposed. This improves differential power processing amongst cells while keeping the voltage and current ratings of the devices low. A battery energy storage system for the multilevel PV converter has also been proposed. Renewable technologies such as PV and wind suffer from varying degrees of intermittency, depending on the geographical location. With increased installation of these sources, management of intermittency is critical to the stability of the grid. The proposed battery system is rated at 10% of the plant it is designed to support. Energy is stored and extracted by means of a bidirectional DC-DC converter connected to the PV DC bus. Different battery chemistries available for this application are also discussed. In this dissertation, the analyses of common mode voltages and currents in various PV topologies are detailed. The grid integration of PV power employs a combination of pulse width modulation (PWM) DC-DC converters and inverters. Due to their fast switching nature a common mode voltage is generated with respect to the ground, inducing a circulating current through the ground capacitance. Common mode voltages lead to increased voltage stress, electromagnetic interference and malfunctioning of ground fault protection systems. Common mode voltages and currents present in high and low power PV systems are analyzed and mitigation strategies such as common mode filter and transformer shielding are proposed to minimize them

    Cascaded Inverters for Grid-Connected Photovoltaic Systems

    Get PDF
    With the extraordinary market growth in grid-connected PV systems, there is increasing interests in grid-connected PV inverters. Focus has been placed on cheap, high-efficiency, and innovative inverter solutions, leading to a high diversity within the inverters and new system configurations. This dissertation chooses cascaded multilevel inverter topologies for grid-connected PV systems to reduce the cost and improve the efficiency. First, a single-phase cascaded H-bridge multilevel PV inverter is discussed. To maximize the solar energy extraction of each PV string, an individual maximum power point tracking (MPPT) control scheme is applied, which allows independent control of each dc-link voltage. A generalized nonactive power theory is applied to generate the reactive current reference. Within the inverter’s capability, the local consumption of reactive power is provided to realize power factor correction. Then, the modular cascaded H-bridge multilevel inverter is connected to a three-phase utility system and nine PV panels. Individual MPPT control is also applied to realize better utilization of PV modules. Also, mismatches between PV panels may introduce unbalanced power supplied to the three-phase grid-connected system. Thus, a modulation compensation scheme is applied to balance the three-phase grid current by injecting a zero sequence voltage. A modular cascaded multilevel inverter prototype has been built and tested in both the single-phase and three-phase PV system. Simulation and experimental results are presented to validate the proposed control schemes. The three-phase cascaded voltage source inverter (VSI), as another cascaded inverter topology, is also proposed for grid-connected PV applications. The equivalent model and average model of the three-phase cascaded VSI are established to realize the central control. In addition, the control scheme applied in the traditional three-phase two-level VSI is modified for this application. Simulation and experimental results are presented as well. The targets of reducing the cost and improving the overall efficiency of the PV inverters can be achieved by applying the cascaded PV inverters and the proposed control schemes

    Grid Connected Distributed Generation System with High Voltage Gain Cascaded DC-DC Converter Fed Asymmetric Multilevel Inverter Topology

    Get PDF
    The paper presents distributed generation (DG) system in grid connected mode of operation with asymmetric multi-level inverter (AMLI) topology. Cascaded type DC-DC converter is employed to feed proposed AMLI topology. The DG output voltage (generally low voltage) is stepped up to the required level of voltage using high-gain DC-DC converter. Proposed AMLI topology consists of capacitors at the primary side. The output of high-gain DC-DC converter is fed to split voltage balance single-input multi-output (SIMO) circuit to maintain voltage balance across capacitors of AMLI topology. Cascaded DC-DC converters (both high-gain converter and SIMO circuit) are operated in closed-loop mode. The proposed AMLI feeds active power to grid converting DC type of power generated from DG to AC type to feed the grid. PWM pattern to trigger power switches of AMLI is also presented. The inverting circuit of MLI topology is controlled using simplified Id-Iq control strategy in this paper. With the proposed control theory, the active power fed to grid from DG is controlled and power factor is maintained at unity. The proposed system of DG integration to grid through cascaded DC-DC converters and AMLI structure is validated from fixed active power to grid from DG condition. The proposed system is developed and results are obtained using MATLAB/SIMULINK software

    Cascaded Converters For Integration And Management Of Grid Level Energy Storage Systems

    Get PDF
    ABSTRACT CASCADED CONVERTERS FOR INTEGRATION AND MANAGEMENT OF GRID-LEVEL ENERGY STORAGE SYSTEMS by ZUHAIR ALAAS December 2017 Advisor: Dr. Caisheng Wang Major: ELECTRICAL ENGINEERING Degree: Doctor of Philosophy This research work proposes two cascaded multilevel inverter structures for BESS. The gating and switching control of switching devices in both inverter typologies are done by using a phase-shifted PWM scheme. The first proposed isolated multilevel inverter is made up of three-phase six-switch inverter blocks with a reduced number of power components compared with traditional isolated CHB. The suggested isolated converter has only one battery string for three-phase system that can be used for high voltage and high power applications such as grid connected BESS and alternative energy systems. The isolated inverter enables dq frame based simple control and eliminates the issues of single-phase pulsating power, which can cause detrimental impacts on certain dc sources. Simulation studies have been carried out to compare the proposed isolated multi-level inverter with an H-bridge cascaded transformer inverter. The simulation results verified the performance of the isolated inverter. The second proposed topology is a Hierarchal Cascaded Multilevel Converter (HCMC) with phase to phase SOC balancing capability which also for high voltage and high power battery energy storage systems. The HCMC has a hybrid structure of half-bridge converters and H-bridge inverters and the voltage can be hierarchically cascaded to reach the desired value at the half-bridge and the H-bridge levels. The uniform SOC battery management is achieved by controlling the half-bridge converters that are connected to individual battery modules/cells. Simulation studies and experimental results have been carried on a large scale battery system under different operating conditions to verify the effectiveness of the proposed inverters. Moreover, this dissertation presents a new three-phase SOC equalizing circuit, called six-switch energy-level balancing circuit (SSBC), which can be used to realize uniform SOC operation for full utilization of the battery capacity in proposed HCMC or any CMI inverter while keeping balanced three-phase operation. A sinusoidal PWM modulation technique is used to control power transferring between phases. Simulation results have been carried out to verify the performance of the proposed SSBC circuit of uniform three-phase SOC balancing

    Design, Optimization and Implementation of a High Frequency Link Multilevel Cascaded Inverter

    Get PDF
    This thesis presents a new concept of cascaded MLI (CMLI) device reduction by utilizing low and high frequency transformer link. Two CMLI topologies, symmetric and asymmetric are proposed. Compared with counterpart CMLI topologies available in the literatures, the proposed two inverter topologies in this thesis have the advantages of utilizing least number of electronic components without compromising overall performance particularly when a high number of levels is required in the output voltage waveform