975 research outputs found

    Multichannel analysis of normal and continuous adventitious respiratory sounds for the assessment of pulmonary function in respiratory diseases

    Get PDF
    Premi extraordinari doctorat UPC curs 2015-2016, àmbit d’Enginyeria IndustrialRespiratory sounds (RS) are produced by turbulent airflows through the airways and are inhomogeneously transmitted through different media to the chest surface, where they can be recorded in a non-invasive way. Due to their mechanical nature and airflow dependence, RS are affected by respiratory diseases that alter the mechanical properties of the respiratory system. Therefore, RS provide useful clinical information about the respiratory system structure and functioning. Recent advances in sensors and signal processing techniques have made RS analysis a more objective and sensitive tool for measuring pulmonary function. However, RS analysis is still rarely used in clinical practice. Lack of a standard methodology for recording and processing RS has led to several different approaches to RS analysis, with some methodological issues that could limit the potential of RS analysis in clinical practice (i.e., measurements with a low number of sensors, no controlled airflows, constant airflows, or forced expiratory manoeuvres, the lack of a co-analysis of different types of RS, or the use of inaccurate techniques for processing RS signals). In this thesis, we propose a novel integrated approach to RS analysis that includes a multichannel recording of RS using a maximum of five microphones placed over the trachea and the chest surface, which allows RS to be analysed at the most commonly reported lung regions, without requiring a large number of sensors. Our approach also includes a progressive respiratory manoeuvres with variable airflow, which allows RS to be analysed depending on airflow. Dual RS analyses of both normal RS and continuous adventitious sounds (CAS) are also proposed. Normal RS are analysed through the RS intensity–airflow curves, whereas CAS are analysed through a customised Hilbert spectrum (HS), adapted to RS signal characteristics. The proposed HS represents a step forward in the analysis of CAS. Using HS allows CAS to be fully characterised with regard to duration, mean frequency, and intensity. Further, the high temporal and frequency resolutions, and the high concentrations of energy of this improved version of HS, allow CAS to be more accurately characterised with our HS than by using spectrogram, which has been the most widely used technique for CAS analysis. Our approach to RS analysis was put into clinical practice by launching two studies in the Pulmonary Function Testing Laboratory of the Germans Trias i Pujol University Hospital for assessing pulmonary function in patients with unilateral phrenic paralysis (UPP), and bronchodilator response (BDR) in patients with asthma. RS and airflow signals were recorded in 10 patients with UPP, 50 patients with asthma, and 20 healthy participants. The analysis of RS intensity–airflow curves proved to be a successful method to detect UPP, since we found significant differences between these curves at the posterior base of the lungs in all patients whereas no differences were found in the healthy participants. To the best of our knowledge, this is the first study that uses a quantitative analysis of RS for assessing UPP. Regarding asthma, we found appreciable changes in the RS intensity–airflow curves and CAS features after bronchodilation in patients with negative BDR in spirometry. Therefore, we suggest that the combined analysis of RS intensity–airflow curves and CAS features—including number, duration, mean frequency, and intensity—seems to be a promising technique for assessing BDR and improving the stratification of BDR levels, particularly among patients with negative BDR in spirometry. The novel approach to RS analysis developed in this thesis provides a sensitive tool to obtain objective and complementary information about pulmonary function in a simple and non-invasive way. Together with spirometry, this approach to RS analysis could have a direct clinical application for improving the assessment of pulmonary function in patients with respiratory diseases.Los sonidos respiratorios (SR) se generan con el paso del flujo de aire a través de las vías respiratorias y se transmiten de forma no homogénea hasta la superficie torácica. Dada su naturaleza mecánica, los SR se ven afectados en gran medida por enfermedades que alteran las propiedades mecánicas del sistema respiratorio. Por lo tanto, los SR proporcionan información clínica relevante sobre la estructura y el funcionamiento del sistema respiratorio. La falta de una metodología estándar para el registro y procesado de los SR ha dado lugar a la aparición de diferentes estrategias de análisis de SR con ciertas limitaciones metodológicas que podrían haber restringido el potencial y el uso de esta técnica en la práctica clínica (medidas con pocos sensores, flujos no controlados o constantes y/o maniobras forzadas, análisis no combinado de distintos tipos de SR o uso de técnicas poco precisas para el procesado de los SR). En esta tesis proponemos un método innovador e integrado de análisis de SR que incluye el registro multicanal de SR mediante un máximo de cinco micrófonos colocados sobre la tráquea yla superficie torácica, los cuales permiten analizar los SR en las principales regiones pulmonares sin utilizar un número elevado de sensores . Nuestro método también incluye una maniobra respiratoria progresiva con flujo variable que permite analizar los SR en función del flujo respiratorio. También proponemos el análisis combinado de los SR normales y los sonidos adventicios continuos (SAC), mediante las curvas intensidad-flujo y un espectro de Hilbert (EH) adaptado a las características de los SR, respectivamente. El EH propuesto representa un avance importante en el análisis de los SAC, pues permite su completa caracterización en términos de duración, frecuencia media e intensidad. Además, la alta resolución temporal y frecuencial y la alta concentración de energía de esta versión mejorada del EH permiten caracterizar los SAC de forma más precisa que utilizando el espectrograma, el cual ha sido la técnica más utilizada para el análisis de SAC en estudios previos. Nuestro método de análisis de SR se trasladó a la práctica clínica a través de dos estudios que se iniciaron en el laboratorio de pruebas funcionales del hospital Germans Trias i Pujol, para la evaluación de la función pulmonar en pacientes con parálisis frénica unilateral (PFU) y la respuesta broncodilatadora (RBD) en pacientes con asma. Las señales de SR y flujo respiratorio se registraron en 10 pacientes con PFU, 50 pacientes con asma y 20 controles sanos. El análisis de las curvas intensidad-flujo resultó ser un método apropiado para detectar la PFU , pues encontramos diferencias significativas entre las curvas intensidad-flujo de las bases posteriores de los pulmones en todos los pacientes , mientras que en los controles sanos no encontramos diferencias significativas. Hasta donde sabemos, este es el primer estudio que utiliza el análisis cuantitativo de los SR para evaluar la PFU. En cuanto al asma, encontramos cambios relevantes en las curvas intensidad-flujo yen las características de los SAC tras la broncodilatación en pacientes con RBD negativa en la espirometría. Por lo tanto, sugerimos que el análisis combinado de las curvas intensidad-flujo y las características de los SAC, incluyendo número, duración, frecuencia media e intensidad, es una técnica prometedora para la evaluación de la RBD y la mejora en la estratificación de los distintos niveles de RBD, especialmente en pacientes con RBD negativa en la espirometría. El método innovador de análisis de SR que se propone en esta tesis proporciona una nueva herramienta con una alta sensibilidad para obtener información objetiva y complementaria sobre la función pulmonar de una forma sencilla y no invasiva. Junto con la espirometría, este método puede tener una aplicación clínica directa en la mejora de la evaluación de la función pulmonar en pacientes con enfermedades respiratoriasAward-winningPostprint (published version

    Diagnosis of pediatric obstructive sleep apnea: Preliminary findingsusing automatic analysis of airflow and oximetry recordings obtainedat patients’ home

    Get PDF
    Producción CientíficaThe obstructive sleep apnea syndrome (OSAS) greatly affects both the health and the quality of life of chil-dren. Therefore, an early diagnosis is crucial to avoid their severe consequences. However, the standarddiagnostic test (polysomnography, PSG) is time-demanding, complex, and costly. We aim at assessinga new methodology for the pediatric OSAS diagnosis to reduce these drawbacks. Airflow (AF) and oxy-gen saturation (SpO2) at-home recordings from 50 children were automatically processed. Informationfrom the spectrum of AF was evaluated, as well as combined with 3% oxygen desaturation index (ODI3)through a logistic regression model. A bootstrap methodology was conducted to validate the results.OSAS significantly increased the spectral content of AF at two abnormal frequency bands below (BW1)and above (BW2) the normal respiratory range. These novel bands are consistent with the occurrenceof apneic events and the posterior respiratory overexertion, respectively. The spectral information fromBW1 and BW2 showed complementarity both between them and with ODI3. A logistic regression modelbuilt with 3 AF spectral features (2 from BW1 and 1 from BW2) and ODI3 achieved (mean and 95% confi-dence interval): 85.9% sensitivity [64.5–98.7]; 87.4% specificity [70.2–98.6]; 86.3% accuracy [74.9–95.4];0.947 area under the receiver-operating characteristics curve [0.826–1]; 88.4% positive predictive value[72.3–98.5]; and 85.8% negative predictive value [65.8–98.5]. The combination of the spectral informationfrom two novel AF bands with the ODI3 from SpO2is useful for the diagnosis of OSAS in children.Ministerio de Economía y Competitividad (project TEC2011-22987)Junta de Castilla y León (project VA059U13

    Measurement and analysis of breath sounds

    Get PDF
    Existing breath sound measurement systems and possible new methods have been critically investigated. The frequency response of each part of the measurement system has been studied. Emphasis has been placed on frequency response of acoustic sensors; especially, a method to study a diaphragm type air-coupler in contact use has been proposed. Two new methods of breath sounds measurement have been studied: laser Doppler vibrometer and mobile phones. It has been shown that these two methods can find applications in breath sounds measurement, however there are some restrictions. A reliable automatic wheeze detection algorithm based on auditory modelling has been developed. That is the human’s auditory system is modelled as a bank of band pass filters, in which the bandwidths are frequency dependent. Wheezes are treated as signals additive to normal breath sounds (masker). Thus wheeze is detectable when it is above the masking threshold. This new algorithm has been validated using simulated and real data. It is superior to previous algorithms, being more reliable to detect wheezes and less prone to mistakes. Simulation of cardiorespiratory sounds and wheeze audibility tests have been developed. Simulated breath sounds can be used as a training tool, as well as an evaluation method. These simulations have shown that, under certain circumstance, there are wheezes but they are inaudible. It is postulated that this could also happen in real measurements. It has been shown that simulated sounds with predefined characteristics can be used as an objective method to evaluate automatic algorithms. Finally, the efficiency and necessity of heart sounds reduction procedures has been investigated. Based on wavelet decomposition and selective synthesis, heart sounds can be reduced with a cost of unnatural breath sounds. Heart sound reduction is shown not to be necessary if a time-frequency representation is used, as heart sounds have a fixed pattern in the time-frequency plane

    SpiroMask: Measuring Lung Function Using Consumer-Grade Masks

    Full text link
    According to the World Health Organisation (WHO), 235 million people suffer from respiratory illnesses and four million people die annually due to air pollution. Regular lung health monitoring can lead to prognoses about deteriorating lung health conditions. This paper presents our system SpiroMask that retrofits a microphone in consumer-grade masks (N95 and cloth masks) for continuous lung health monitoring. We evaluate our approach on 48 participants (including 14 with lung health issues) and find that we can estimate parameters such as lung volume and respiration rate within the approved error range by the American Thoracic Society (ATS). Further, we show that our approach is robust to sensor placement inside the mask.Comment: Accepted in the ACM Transactions on Computing for Healthcare (HEALTH

    Cervical auscultation in the diagnosis of oropharyngeal aspiration in children: a study protocol for a randomised controlled trial

    Get PDF
    BackgroundOropharyngeal aspiration (OPA) can lead to recurrent respiratory illnesses and chronic lung disease in children. Current clinical feeding evaluations performed by speech pathologists have poor reliability in detecting OPA when compared to radiological procedures such as the modified barium swallow (MBS). Improved ability to diagnose OPA accurately via clinical evaluation potentially reduces reliance on expensive, less readily available radiological procedures. Our study investigates the utility of adding cervical auscultation (CA), a technique of listening to swallowing sounds, in improving the diagnostic accuracy of a clinical evaluation for the detection of OPA. MethodsWe plan an open, unblinded, randomised controlled trial at a paediatric tertiary teaching hospital. Two hundred and sixteen children fulfilling the inclusion criteria will be randomised to one of the two clinical assessment techniques for the clinical detection of OPA: (1) clinical feeding evaluation only (CFE) group or (2) clinical feeding evaluation with cervical auscultation (CFE + CA) group. All children will then undergo an MBS to determine radiologically assessed OPA. The primary outcome is the presence or absence of OPA, as determined on MBS using the Penetration-Aspiration Scale. Our main objective is to determine the sensitivity, specificity, negative and positive predictive values of ‘CFE + CA’ versus ‘CFE’ only compared to MBS-identified OPA. DiscussionEarly detection and appropriate management of OPA is important to prevent chronic pulmonary disease and poor growth in children. As the reliability of CFE to detect OPA is low, a technique that can improve the diagnostic accuracy of the CFE will help minimise consequences to the paediatric respiratory system. Cervical auscultation is a technique that has previously been documented as a clinical adjunct to the CFE; however, no published RCTs addressing the reliability of this technique in children exist. Our study will be the first to establish the utility of CA in assessing and diagnosing OPA risk in young children

    New Models for Expert System Design

    Get PDF
    This thesis presents new work on the analysis of human lung sound. Experimental studies investigated the relationship between the condition of the lungs and the power spectrum of lung sound detected at the chest wall. The conclusion drawn from two clinical studies was that the median frequency of the lung sound power spectrum increases with a decrease in airway calibre. The technique for the analysis of lung sound presented in this thesis is a non-invasive method which may be capable of assessing differences in airway calibre between different lobes of the lung. An expert system for the analysis of lung sound data and pulmonary function data was designed. The expert knowledge was expressed in a belief logic, a system of logic which is more expressive than first order logic. New automated theorem proving methods were developed for the belief logic. The new methods were implemented to form the 'inference engine' of the expert system. The new expert system compared favourably with systems which perform a similar task. The use of belief logic allows introspective reasoning to be carried out. Plausible reasoning, a type of introspective reasoning which allows conclusions to be drawn when the database is incomplete, was proposed and tested. The author concludes that the use of a belief logic in expert system design has significant advantages over conventional approaches. The experimental results of the lung sound research were incorporated into the expert system rule base: the medical and expert system research were complementary

    Models and Analysis of Vocal Emissions for Biomedical Applications

    Get PDF
    The International Workshop on Models and Analysis of Vocal Emissions for Biomedical Applications (MAVEBA) came into being in 1999 from the particularly felt need of sharing know-how, objectives and results between areas that until then seemed quite distinct such as bioengineering, medicine and singing. MAVEBA deals with all aspects concerning the study of the human voice with applications ranging from the newborn to the adult and elderly. Over the years the initial issues have grown and spread also in other fields of research such as occupational voice disorders, neurology, rehabilitation, image and video analysis. MAVEBA takes place every two years in Firenze, Italy. This edition celebrates twenty-two years of uninterrupted and successful research in the field of voice analysis
    corecore