3,797 research outputs found

    Autocamera Calibration for traffic surveillance cameras with wide angle lenses

    Full text link
    We propose a method for automatic calibration of a traffic surveillance camera with wide-angle lenses. Video footage of a few minutes is sufficient for the entire calibration process to take place. This method takes in the height of the camera from the ground plane as the only user input to overcome the scale ambiguity. The calibration is performed in two stages, 1. Intrinsic Calibration 2. Extrinsic Calibration. Intrinsic calibration is achieved by assuming an equidistant fisheye distortion and an ideal camera model. Extrinsic calibration is accomplished by estimating the two vanishing points, on the ground plane, from the motion of vehicles at perpendicular intersections. The first stage of intrinsic calibration is also valid for thermal cameras. Experiments have been conducted to demonstrate the effectiveness of this approach on visible as well as thermal cameras. Index Terms: fish-eye, calibration, thermal camera, intelligent transportation systems, vanishing point

    Simple fish-eye calibration method with accuracy evaluation

    Get PDF
    In this paper, a simple fish-eye radial distortion calibration procedure is described. This method avoids costly minimisation and optimisation algorithms, and is based on trivial concentricity of three extracted points. The results show that this simplicity is at the expense of increased deviation of results (and thus increased error). However, this deviation can be reduced significantly by the use of simple averaging, such that it is only marginally greater than the current state-of-the-art

    A flexible technique for accurate omnidirectional camera calibration and structure from motion

    Get PDF
    In this paper, we present a flexible new technique for single viewpoint omnidirectional camera calibration. The proposed method only requires the camera to observe a planar pattern shown at a few different orientations. Either the camera or the planar pattern can be freely moved. No a priori knowledge of the motion is required, nor a specific model of the omnidirectional sensor. The only assumption is that the image projection function can be described by a Taylor series expansion whose coefficients are estimated by solving a two-step least-squares linear minimization problem. To test the proposed technique, we calibrated a panoramic camera having a field of view greater than 200° in the vertical direction, and we obtained very good results. To investigate the accuracy of the calibration, we also used the estimated omni-camera model in a structure from motion experiment. We obtained a 3D metric reconstruction of a scene from two highly distorted omnidirectional images by using image correspondences only. Compared with classical techniques, which rely on a specific parametric model of the omnidirectional camera, the proposed procedure is independent of the sensor, easy to use, and flexible. 1

    Towards the development of a smart flying sensor: illustration in the field of precision agriculture

    Get PDF
    Sensing is an important element to quantify productivity, product quality and to make decisions. Applications, such as mapping, surveillance, exploration and precision agriculture, require a reliable platform for remote sensing. This paper presents the first steps towards the development of a smart flying sensor based on an unmanned aerial vehicle (UAV). The concept of smart remote sensing is illustrated and its performance tested for the task of mapping the volume of grain inside a trailer during forage harvesting. Novelty lies in: (1) the development of a position-estimation method with time delay compensation based on inertial measurement unit (IMU) sensors and image processing; (2) a method to build a 3D map using information obtained from a regular camera; and (3) the design and implementation of a path-following control algorithm using model predictive control (MPC). Experimental results on a lab-scale system validate the effectiveness of the proposed methodology

    The Geometry and Usage of the Supplementary Fisheye Lenses in Smartphones

    Get PDF
    Nowadays, mobile phones are more than a device that can only satisfy the communication need between people. Since fisheye lenses integrated with mobile phones are lightweight and easy to use, they are advantageous. In addition to this advantage, it is experimented whether fisheye lens and mobile phone combination can be used in a photogrammetric way, and if so, what will be the result. Fisheye lens equipment used with mobile phones was tested in this study. For this, standard calibration of ‘Olloclip 3 in one’ fisheye lens used with iPhone 4S mobile phone and ‘Nikon FC‐E9’ fisheye lens used with Nikon Coolpix8700 are compared based on equidistant model. This experimental study shows that Olloclip 3 in one fisheye lens developed for mobile phones has at least the similar characteristics with classic fisheye lenses. The dimensions of fisheye lenses used with smart phones are getting smaller and the prices are reducing. Moreover, as verified in this study, the accuracy of fisheye lenses used in smartphones is better than conventional fisheye lenses. The use of smartphones with fisheye lenses will give the possibility of practical applications to ordinary users in the near future

    Photogrammetry System and Method for Determining Relative Motion Between Two Bodies

    Get PDF
    A photogrammetry system and method provide for determining the relative position between two objects. The system utilizes one or more imaging devices, such as high speed cameras, that are mounted on a first body, and three or more photogrammetry targets of a known location on a second body. The system and method can be utilized with cameras having fish-eye, hyperbolic, omnidirectional, or other lenses. The system and method do not require overlapping fields-of-view if two or more cameras are utilized. The system and method derive relative orientation by equally weighting information from an arbitrary number of heterogeneous cameras, all with non-overlapping fields-of-view. Furthermore, the system can make the measurements with arbitrary wide-angle lenses on the cameras
    corecore