    Addressing the challenges posed by human machine interfaces based on force sensitive resistors for powered prostheses

    Get PDF
    Despite the advancements in the mechatronics aspect of prosthetic devices, prostheses control still lacks an interface that satisfies the needs of the majority of users. The research community has put great effort into the advancements of prostheses control techniques to address users’ needs. However, most of these efforts are focused on the development and assessment of technologies in the controlled environments of laboratories. Such findings do not fully transfer to the daily application of prosthetic systems. The objectives of this thesis focus on factors that affect the use of Force Myography (FMG) controlled prostheses in practical scenarios. The first objective of this thesis assessed the use of FMG as an alternative or synergist Human Machine Interface (HMI) to the more traditional HMI, i.e. surface Electromyography (sEMG). The assessment for this study was conducted in conditions that are relatively close to the real use case of prosthetic applications. The HMI was embedded in the custom prosthetic prototype that was developed for the pilot participant of the study using an off-the-shelf prosthetic end effector. Moreover, prostheses control was assessed as the user moved their limb in a dynamic protocol.The results of the aforementioned study motivated the second objective of this thesis: to investigate the possibility of reducing the complexity of high density FMG systems without sacrificing classification accuracies. This was achieved through a design method that uses a high density FMG apparatus and feature selection to determine the number and location of sensors that can be eliminated without significantly sacrificing the system’s performance. The third objective of this thesis investigated two of the factors that contribute to increased errors in force sensitive resistor (FSR) signals used in FMG controlled prostheses: bending of force sensors and variations in the volume of the residual limb. Two studies were conducted that proposed solutions to mitigate the negative impact of these factors. The incorporation of these solutions into prosthetic devices is discussed in these studies.It was demonstrated that FMG is a promising HMI for prostheses control. The facilitation of pattern recognition with FMG showed potential for intuitive prosthetic control. Moreover, a method for the design of a system that can determine the required number of sensors and their locations on each individual to achieve a simpler system with comparable performance to high density FMG systems was proposed and tested. The effects of the two factors considered in the third objective were determined. It was also demonstrated that the proposed solutions in the studies conducted for this objective can be used to increase the accuracy of signals that are commonly used in FMG controlled prostheses

    The "Federica" hand: a simple, very efficient prothesis

    Get PDF
    Hand prostheses partially restore hand appearance and functionalities. Not everyone can afford expensive prostheses and many low-cost prostheses have been proposed. In particular, 3D printers have provided great opportunities by simplifying the manufacturing process and reducing costs. Generally, active prostheses use multiple motors for fingers movement and are controlled by electromyographic (EMG) signals. The "Federica" hand is a single motor prosthesis, equipped with an adaptive grasp and controlled by a force-myographic signal. The "Federica" hand is 3D printed and has an anthropomorphic morphology with five fingers, each consisting of three phalanges. The movement generated by a single servomotor is transmitted to the fingers by inextensible tendons that form a closed chain; practically, no springs are used for passive hand opening. A differential mechanical system simultaneously distributes the motor force in predefined portions on each finger, regardless of their actual positions. Proportional control of hand closure is achieved by measuring the contraction of residual limb muscles by means of a force sensor, replacing the EMG. The electrical current of the servomotor is monitored to provide the user with a sensory feedback of the grip force, through a small vibration motor. A simple Arduino board was adopted as processing unit. The differential mechanism guarantees an efficient transfer of mechanical energy from the motor to the fingers and a secure grasp of any object, regardless of its shape and deformability. The force sensor, being extremely thin, can be easily embedded into the prosthesis socket and positioned on both muscles and tendons; it offers some advantages over the EMG as it does not require any electrical contact or signal processing to extract information about the muscle contraction intensity. The grip speed is high enough to allow the user to grab objects on the fly: from the muscle trigger until to the complete hand closure, "Federica" takes about half a second. The cost of the device is about 100 US$. Preliminary tests carried out on a patient with transcarpal amputation, showed high performances in controlling the prosthesis, after a very rapid training session. The "Federica" hand turned out to be a lightweight, low-cost and extremely efficient prosthesis. The project is intended to be open-source: all the information needed to produce the prosthesis (e.g. CAD files, circuit schematics, software) can be downloaded from a public repository. Thus, allowing everyone to use the "Federica" hand and customize or improve it

    Towards electrodeless EMG linear envelope signal recording for myo-activated prostheses control

    Get PDF
    After amputation, the residual muscles of the limb may function in a normal way, enabling the electromyogram (EMG) signals recorded from them to be used to drive a replacement limb. These replacement limbs are called myoelectric prosthesis. The prostheses that use EMG have always been the first choice for both clinicians and engineers. Unfortunately, due to the many drawbacks of EMG (e.g. skin preparation, electromagnetic interferences, high sample rate, etc.); researchers have aspired to find suitable alternatives. One proposes the dry-contact, low-cost sensor based on a force-sensitive resistor (FSR) as a valid alternative which instead of detecting electrical events, detects mechanical events of muscle. FSR sensor is placed on the skin through a hard, circular base to sense the muscle contraction and to acquire the signal. Similarly, to reduce the output drift (resistance) caused by FSR edges (creep) and to maintain the FSR sensitivity over a wide input force range, signal conditioning (Voltage output proportional to force) is implemented. This FSR signal acquired using FSR sensor can be used directly to replace the EMG linear envelope (an important control signal in prosthetics applications). To find the best FSR position(s) to replace a single EMG lead, the simultaneous recording of EMG and FSR output is performed. Three FSRs are placed directly over the EMG electrodes, in the middle of the targeted muscle and then the individual (FSR1, FSR2 and FSR3) and combination of FSR (e.g. FSR1+FSR2, FSR2-FSR3) is evaluated. The experiment is performed on a small sample of five volunteer subjects. The result shows a high correlation (up to 0.94) between FSR output and EMG linear envelope. Consequently, the usage of the best FSR sensor position shows the ability of electrode less FSR-LE to proportionally control the prosthesis (3-D claw). Furthermore, FSR can be used to develop a universal programmable muscle signal sensor that can be suitable to control the myo-activated prosthesis

    Design of a low-cost sensor matrix for use in human-machine interactions on the basis of myographic information

    Get PDF
    Myographic sensor matrices in the field of human-machine interfaces are often poorly developed and not pushing the limits in terms of a high spatial resolution. Many studies use sensor matrices as a tool to access myographic data for intention prediction algorithms regardless of the human anatomy and used sensor principles. The necessity for more sophisticated sensor matrices in the field of myographic human-machine interfaces is essential, and the community already called out for new sensor solutions. This work follows the neuromechanics of the human and designs customized sensor principles to acquire the occurring phenomena. Three low-cost sensor modalities Electromyography, Mechanomyography, and Force Myography) were developed in a miniaturized size and tested in a pre-evaluation study. All three sensors comprise the characteristic myographic information of its modality. Based on the pre-evaluated sensors, a sensor matrix with 32 exchangeable and high-density sensor modules was designed. The sensor matrix can be applied around the human limbs and takes the human anatomy into account. A data transmission protocol was customized for interfacing the sensor matrix to the periphery with reduced wiring. The designed sensor matrix offers high-density and multimodal myographic information for the field of human-machine interfaces. Especially the fields of prosthetics and telepresence can benefit from the higher spatial resolution of the sensor matrix

    Novel Bidirectional Body - Machine Interface to Control Upper Limb Prosthesis

    Get PDF
    Objective. The journey of a bionic prosthetic user is characterized by the opportunities and limitations involved in adopting a device (the prosthesis) that should enable activities of daily living (ADL). Within this context, experiencing a bionic hand as a functional (and, possibly, embodied) limb constitutes the premise for mitigating the risk of its abandonment through the continuous use of the device. To achieve such a result, different aspects must be considered for making the artificial limb an effective support for carrying out ADLs. Among them, intuitive and robust control is fundamental to improving amputees’ quality of life using upper limb prostheses. Still, as artificial proprioception is essential to perceive the prosthesis movement without constant visual attention, a good control framework may not be enough to restore practical functionality to the limb. To overcome this, bidirectional communication between the user and the prosthesis has been recently introduced and is a requirement of utmost importance in developing prosthetic hands. Indeed, closing the control loop between the user and a prosthesis by providing artificial sensory feedback is a fundamental step towards the complete restoration of the lost sensory-motor functions. Within my PhD work, I proposed the development of a more controllable and sensitive human-like hand prosthesis, i.e., the Hannes prosthetic hand, to improve its usability and effectiveness. Approach. To achieve the objectives of this thesis work, I developed a modular and scalable software and firmware architecture to control the Hannes prosthetic multi-Degree of Freedom (DoF) system and to fit all users’ needs (hand aperture, wrist rotation, and wrist flexion in different combinations). On top of this, I developed several Pattern Recognition (PR) algorithms to translate electromyographic (EMG) activity into complex movements. However, stability and repeatability were still unmet requirements in multi-DoF upper limb systems; hence, I started by investigating different strategies to produce a more robust control. To do this, EMG signals were collected from trans-radial amputees using an array of up to six sensors placed over the skin. Secondly, I developed a vibrotactile system to implement haptic feedback to restore proprioception and create a bidirectional connection between the user and the prosthesis. Similarly, I implemented an object stiffness detection to restore tactile sensation able to connect the user with the external word. This closed-loop control between EMG and vibration feedback is essential to implementing a Bidirectional Body - Machine Interface to impact amputees’ daily life strongly. For each of these three activities: (i) implementation of robust pattern recognition control algorithms, (ii) restoration of proprioception, and (iii) restoration of the feeling of the grasped object's stiffness, I performed a study where data from healthy subjects and amputees was collected, in order to demonstrate the efficacy and usability of my implementations. In each study, I evaluated both the algorithms and the subjects’ ability to use the prosthesis by means of the F1Score parameter (offline) and the Target Achievement Control test-TAC (online). With this test, I analyzed the error rate, path efficiency, and time efficiency in completing different tasks. Main results. Among the several tested methods for Pattern Recognition, the Non-Linear Logistic Regression (NLR) resulted to be the best algorithm in terms of F1Score (99%, robustness), whereas the minimum number of electrodes needed for its functioning was determined to be 4 in the conducted offline analyses. Further, I demonstrated that its low computational burden allowed its implementation and integration on a microcontroller running at a sampling frequency of 300Hz (efficiency). Finally, the online implementation allowed the subject to simultaneously control the Hannes prosthesis DoFs, in a bioinspired and human-like way. In addition, I performed further tests with the same NLR-based control by endowing it with closed-loop proprioceptive feedback. In this scenario, the results achieved during the TAC test obtained an error rate of 15% and a path efficiency of 60% in experiments where no sources of information were available (no visual and no audio feedback). Such results demonstrated an improvement in the controllability of the system with an impact on user experience. Significance. The obtained results confirmed the hypothesis of improving robustness and efficiency of a prosthetic control thanks to of the implemented closed-loop approach. The bidirectional communication between the user and the prosthesis is capable to restore the loss of sensory functionality, with promising implications on direct translation in the clinical practice

    Machine learning and processing techniques for the enhancement of hand gesture recognition of Forcemyography and Electromyography signals

    Get PDF
    Hand gesture recognition is the primary driver of many applications across user groups. It uses machine learning classifiers to classify users’ data, most prominently Electromyography (EMG) or Forcemyography (FMG). Whereas EMG sensors detect signals going down the arm to the muscles, FMG sensors measure the pressure change on the arm’s skin. Nevertheless, many inconsistencies impact gesture recognition drastically. For instance, gesture recognition for the same user, intra-subject, is affected by the duration between the collected signals for classifiers’ training and the classified signals, requiring more data from the user. A more significant hurdle is inter-subject gesture error, in which classifiers are trained on signals from one or more subjects perform exceptionally poorly on the signals of another. These issues arise due to the uniqueness of such signals per person and their variance through time. We offer methods to encounter several downsides of EMG and FMG. We propose a machine learning pipeline that yields features of consistent performance across various classifier types and reduces intra-subject signal variance. To tackle other intra-subject errors, we offer a ranking for what we define as the feature-classifier compatibility relationship that controls the recognition performance. The methods are tested on FMG and EMG, respectively, and enhanced gesture recognition

    A study of the influence of low intensity laser therapy on painful temporomandibular disorders

    Get PDF
    PhDAn analgesic effect is one of the reported results of Low Intensity Laser Therapy (LILT). Even though this therapy has been extensively used to treat musculoskeletal injury, pain and inflammation, there is still a lack of research concerning the ideal parameters and mechanism of action of LILT on painful Temporomandibular Disorders (TMD). This thesis sets out to compare clinical responses to the 820 nm Gallium Aluminium. Arsenide (GaAlAs) laser at two energy levels and placebo laser in TMD Pain patients. Additionally, in vitro studies were conducted to explore the effect of 820 nM radiation on Prostaglandin E2 (PGE2) production by myoblast cultures undergoing stretching and stimulation by Interleukin I alpha (IL-1). A double-blind clinical trial was conducted on 30 female TMD pain patients. The patients were randomly allocated into three groups based on LILT regimes namely 820 nm GaAlAs at energy density of 21 and 107 J/cml and placebo laser. Each patient had three LILT treatments in a week. The pressure pain threshold (PPT) of trigger points in masticatory muscles, unassisted maximum mouth opening without pain (MOSP) and symptom severity index (SSI) were recorded as baseline data and monitored after every treatment. jaw kinesiology and electromyography (EMG) were also recorded as baseline and final results. The analysis of covariance and the further analysis showed that the higher energy density laser group had significant increases in PPT and EMG amplitude recorded from voluntary clenching (cEMG) compared with the placebo group at P values 0.0001 and 0.022 respectively. A significantly greater number of patients recovered from myofascial. pain and TMJ arthralgia as assessed clinically in the higher energy group compared with the placebo (P value = 0.012 and 0.001 respectively). There was no statistically significant difference of parameters of assessment among the groups at aP value 0.05. At a period of 2 to 4 weeks review after LILT, there was an average 52% reduction of pain as assessed by SSI pain questionnaire. The control in vitro studies on the influence of LELT on PGE2 production were conducted on differentiated C202 skeletal muscle cells stimulated by mechanical stretching and IL-I supplement. The two models of PGE2 stimulation showed significantly higher amounts of PGE2 production compared with the no intervention group. The results from the model using mechanical stretching to stimulate PGE2 synthesis showed no inhibitory effect from 820 nm GaAlAs laser at least in the energy densities used in this study which were 0.6 J/CM2 and 3.1 J/cmI. In the other experiment, IL-1 supplement was used to stimulate PGE2 which was observed to occur in the sham laser and lower energy laser at 4 J/CM2 groups. However, the higher energy laser group at 19 J/cm' showed reduced PGE2 synthesis with no statistically significant difference from a no intervention group where no IL-1 was added. This indicates that 820 nm radiation at higher energy density appears capable of inhibiting PGE2 formation and this may be one of the mechanisms of the analgesic effect of GaAlAs LILT on trigger points in muscle. Overall Low Intensity Laser Therapy (LILT) given at high energy density has been shown to be a valuable addition to the repertoire of treatment methods for Temporomandibular Pain Disorder

    Smart Sensors for Healthcare and Medical Applications

    Get PDF
    This book focuses on new sensing technologies, measurement techniques, and their applications in medicine and healthcare. Specifically, the book briefly describes the potential of smart sensors in the aforementioned applications, collecting 24 articles selected and published in the Special Issue “Smart Sensors for Healthcare and Medical Applications”. We proposed this topic, being aware of the pivotal role that smart sensors can play in the improvement of healthcare services in both acute and chronic conditions as well as in prevention for a healthy life and active aging. The articles selected in this book cover a variety of topics related to the design, validation, and application of smart sensors to healthcare

    Markerless Human Motion Analysis

    Get PDF
    Measuring and understanding human motion is crucial in several domains, ranging from neuroscience, to rehabilitation and sports biomechanics. Quantitative information about human motion is fundamental to study how our Central Nervous System controls and organizes movements to functionally evaluate motor performance and deficits. In the last decades, the research in this field has made considerable progress. State-of-the-art technologies that provide useful and accurate quantitative measures rely on marker-based systems. Unfortunately, markers are intrusive and their number and location must be determined a priori. Also, marker-based systems require expensive laboratory settings with several infrared cameras. This could modify the naturalness of a subject\u2019s movements and induce discomfort. Last, but not less important, they are computationally expensive in time and space. Recent advances on markerless pose estimation based on computer vision and deep neural networks are opening the possibility of adopting efficient video-based methods for extracting movement information from RGB video data. In this contest, this thesis presents original contributions to the following objectives: (i) the implementation of a video-based markerless pipeline to quantitatively characterize human motion; (ii) the assessment of its accuracy if compared with a gold standard marker-based system; (iii) the application of the pipeline to different domains in order to verify its versatility, with a special focus on the characterization of the motion of preterm infants and on gait analysis. With the proposed approach we highlight that, starting only from RGB videos and leveraging computer vision and machine learning techniques, it is possible to extract reliable information characterizing human motion comparable to that obtained with gold standard marker-based systems