16 research outputs found

    Characterization and processing of atrial fibrillation episodes by convolutive blind source separation algorithms and nonlinear analysis of spectral features

    Full text link
    Las arritmias supraventriculares, en particular la fibrilación auricular (FA), son las enfermedades cardíacas más comúnmente encontradas en la práctica clínica rutinaria. La prevalencia de la FA es inferior al 1\% en la población menor de 60 años, pero aumenta de manera significativa a partir de los 70 años, acercándose al 10\% en los mayores de 80. El padecimiento de un episodio de FA sostenida, además de estar ligado a una mayor tasa de mortalidad, aumenta la probabilidad de sufrir tromboembolismo, infarto de miocardio y accidentes cerebrovasculares. Por otro lado, los episodios de FA paroxística, aquella que termina de manera espontánea, son los precursores de la FA sostenida, lo que suscita un alto interés entre la comunidad científica por conocer los mecanismos responsables de perpetuar o conducir a la terminación espontánea de los episodios de FA. El análisis del ECG de superficie es la técnica no invasiva más extendida en la diagnosis médica de las patologías cardíacas. Para utilizar el ECG como herramienta de estudio de la FA, se necesita separar la actividad auricular (AA) de las demás señales cardioeléctricas. En este sentido, las técnicas de Separación Ciega de Fuentes (BSS) son capaces de realizar un análisis estadístico multiderivación con el objetivo de recuperar un conjunto de fuentes cardioeléctricas independientes, entre las cuales se encuentra la AA. A la hora de abordar un problema de BSS, se hace necesario considerar un modelo de mezcla de las fuentes lo más ajustado posible a la realidad para poder desarrollar algoritmos matemáticos que lo resuelvan. Un modelo viable es aquel que supone mezclas lineales. Dentro del modelo de mezclas lineales se puede además hacer la restricción de que estas sean instantáneas. Este modelo de mezcla lineal instantánea es el utilizado en el Análisis de Componentes Independientes (ICA).Vayá Salort, C. (2010). Characterization and processing of atrial fibrillation episodes by convolutive blind source separation algorithms and nonlinear analysis of spectral features [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/8416Palanci

    Blind Source Separation for the Processing of Contact-Less Biosignals

    Get PDF
    (Spatio-temporale) Blind Source Separation (BSS) eignet sich für die Verarbeitung von Multikanal-Messungen im Bereich der kontaktlosen Biosignalerfassung. Ziel der BSS ist dabei die Trennung von (z.B. kardialen) Nutzsignalen und Störsignalen typisch für die kontaktlosen Messtechniken. Das Potential der BSS kann praktisch nur ausgeschöpft werden, wenn (1) ein geeignetes BSS-Modell verwendet wird, welches der Komplexität der Multikanal-Messung gerecht wird und (2) die unbestimmte Permutation unter den BSS-Ausgangssignalen gelöst wird, d.h. das Nutzsignal praktisch automatisiert identifiziert werden kann. Die vorliegende Arbeit entwirft ein Framework, mit dessen Hilfe die Effizienz von BSS-Algorithmen im Kontext des kamera-basierten Photoplethysmogramms bewertet werden kann. Empfehlungen zur Auswahl bestimmter Algorithmen im Zusammenhang mit spezifischen Signal-Charakteristiken werden abgeleitet. Außerdem werden im Rahmen der Arbeit Konzepte für die automatisierte Kanalauswahl nach BSS im Bereich der kontaktlosen Messung des Elektrokardiogramms entwickelt und bewertet. Neuartige Algorithmen basierend auf Sparse Coding erwiesen sich dabei als besonders effizient im Vergleich zu Standard-Methoden.(Spatio-temporal) Blind Source Separation (BSS) provides a large potential to process distorted multichannel biosignal measurements in the context of novel contact-less recording techniques for separating distortions from the cardiac signal of interest. This potential can only be practically utilized (1) if a BSS model is applied that matches the complexity of the measurement, i.e. the signal mixture and (2) if permutation indeterminacy is solved among the BSS output components, i.e the component of interest can be practically selected. The present work, first, designs a framework to assess the efficacy of BSS algorithms in the context of the camera-based photoplethysmogram (cbPPG) and characterizes multiple BSS algorithms, accordingly. Algorithm selection recommendations for certain mixture characteristics are derived. Second, the present work develops and evaluates concepts to solve permutation indeterminacy for BSS outputs of contact-less electrocardiogram (ECG) recordings. The novel approach based on sparse coding is shown to outperform the existing concepts of higher order moments and frequency-domain features

    Exploiting periodicity to extract the atrial activity in atrial arrhythmias

    Get PDF
    [EN] Atrial fibrillation disorders are one of the main arrhythmias of the elderly. The atrial and ventricular activities are decoupled during an atrial fibrillation episode, and very rapid and irregular waves replace the usual atrial P-wave in a normal sinus rhythm electrocardiogram (ECG). The estimation of these wavelets is a must for clinical analysis. We propose a new approach to this problem focused on the quasiperiodicity of these wavelets. Atrial activity is characterized by a main atrial rhythm in the interval 3-12 Hz. It enables us to establish the problem as the separation of the original sources from the instantaneous linear combination of them recorded in the ECG or the extraction of only the atrial component exploiting the quasiperiodic feature of the atrial signal. This methodology implies the previous estimation of such main atrial period. We present two algorithms that separate and extract the atrial rhythm starting from a prior estimation of the main atrial frequency. The first one is an algebraic method based on the maximization of a cost function that measures the periodicity. The other one is an adaptive algorithm that exploits the decorrelation of the atrial and other signals diagonalizing the correlation matrices at multiple lags of the period of atrial activity. The algorithms are applied successfully to synthetic and real data. In simulated ECGs, the average correlation index obtained was 0.811 and 0.847, respectively. In real ECGs, the accuracy of the results was validated using spectral and temporal parameters. The average peak frequency and spectral concentration obtained were 5.550 and 5.554 Hz and 56.3 and 54.4%, respectively, and the kurtosis was 0.266 and 0.695. For validation purposes, we compared the proposed algorithms with established methods, obtaining better results for simulated and real registers.This paper is in part supported by the Valencia Regional Government (Generalitat Valenciana) through project GV/2010/002 (Conselleria d'Educacio) and by the Universidad Politecnica de Valencia under grant no. PAID-06-09-003-382.Llinares Llopis, R.; Igual García, J. (2011). Exploiting periodicity to extract the atrial activity in atrial arrhythmias. EURASIP Journal on Advances in Signal Processing. 1(134):1-16. doi:10.1186/1687-6180-2011-134S1161134Rieta J, Castells F, Sanchez C, Zarzoso V, Millet J: IEEE Trans Biomed Eng. 2004,51(7):1176. 10.1109/TBME.2004.827272Fuster V, Ryden L, Asinger R, et al.: Circulation. 2001, 104: 2118.Sörnmo L, Stridh M, Husser D, Bollmann A, Olsson S: Philos Trans A. 2009,367(1887):235. 10.1098/rsta.2008.0162Bollmann A, Husser D, Mainardi L, Lombardi F, Langley P, Murray A, Rieta J, Millet J, Olsson S, Stridh M, Sörnmo L: Europace. 2006,8(11):911. 10.1093/europace/eul113Stridh M, Sornmo L, Meurling C, Olsson S: IEEE Trans Biomed Eng. 2004,51(1):100. 10.1109/TBME.2003.820331Asano Y, Saito J, Matsumoto K, Kaneko K, Yamamoto T, Uchida M: Am J Cardiol. 1992,69(12):1033. 10.1016/0002-9149(92)90859-WStambler B, Wood M, Ellenbogen K: Circulation. 1997,96(12):4298.Manios E, Kanoupakis E, Chlouverakis G, Kaleboubas M, Mavrakis H, Vardas P: Cardiovasc Res. 2000,47(2):244. 10.1016/S0008-6363(00)00100-0Stridh M, Sornmo L: IEEE Trans Biomed Eng. 2001,48(1):105. 10.1109/10.900266Castells F, Igual J, Rieta J, Sanchez C, Millet J: Proceedings of the IEEE International Conference on Acoustics, Speech, and Signal Processing (ICASSP'03). 2003., 5:Castells F, Rieta J, Millet J, Zarzoso V: IEEE Trans Biomed Eng. 2005,52(2):258. 10.1109/TBME.2004.840473Petrutiu S, Ng J, Nijm G, Al-Angari H, Swiryn S, Sahakian A: IEEE Eng Med Biol Mag. 2006,25(6):24.Stridh M, Bollmann A, Olsson S, Sornmo L: IEEE Eng Med Biol Mag. 2006,25(6):31.Langley P, Bourke J, Murray A: Computers in Cardiology. 2000.Sassi R, Corino V, Mainardi L: Ann Biomed Eng. 2009,37(10):2082-921. 10.1007/s10439-009-9757-3Llinares R, Igual J, Salazar A, Camacho A: Digit Signal Process. 2011,21(2):391. 10.1016/j.dsp.2010.06.005Sameni R, Jutten C, Shamsollahi M: IEEE Trans Biomed Eng. 2008,55(8):1935.Li X: IEEE Signal Process Lett. 2006,14(1):58.Llinares R, Igual J, Miró-Borrás J: Comput Biol Med. 2010,40(11-12):943. 10.1016/j.compbiomed.2010.10.006Belouchrani A, Abed-Meraim K, Cardoso J, Moulines E: IEEE Trans Signal Process. 1997,45(2):434. 10.1109/78.554307Lemay M, Vesin J, van Oosterom A, Jacquemet V, Kappenberger L: IEEE Trans Biomed Eng. 2007,54(3):542.Alcaraz R, Rieta J: Physiol Meas. 2008,29(12):1351. 10.1088/0967-3334/29/12/00

    Independent Component Analysis in ECG Signal Processing

    Get PDF

    Relationship between body surface potential maps and atrial electrograms in patients with atrial fibrillation

    Get PDF
    PhD ThesisAtrial fibrillation (AF) is the most common cardiac arrhythmia. It is distinguished by fibrillating or trembling of the atrial muscle instead of normal contraction. Patients in AF have a much higher risk of stroke. AF is often driven by the left atrium (LA) and the diagnosis of AF is normally made from lead V1 in a 12-lead electrocardiogram (ECG). However, lead V1 is dominated by right atrial activity due to its proximal location to the right atrium (RA). Consequently it is not well understood how electrical activity from the LA contributes to the ECG. Studies of the AF mechanisms from the LA are typically based on invasive recording techniques. From a clinical point of view it is highly desirable to have an alternative, non-invasive characterisation of AF. The aim of this study was to investigate how the LA electrical activity was expressed on the body surface, and if it could be observed preferentially in different sites on the body surface. For this purpose, electrical activity of the heart from 20 patients in AF were recorded simultaneously using 64-lead body surface potential mapping (BSPM) and bipolar 10-electrode catheters located in the LA and coronary sinus (CS). Established AF characteristics such as amplitude, dominant frequency (DF) and spectral concentration (SC) were estimated and analysed. Furthermore, two novel AF characteristics (intracardiac DF power distribution, and body surface spectral peak type) were proposed to investigate the relationship between the BSPM and electrogram (EGM) recordings. The results showed that although in individual patients there were body surface sites that preferentially represented the AF characteristics estimated from the LA, those sites were not consistent across all patients. It was found that the left atrial activity could be detected in all body surface sites such that all sites had a dominant or non-dominant spectral peak corresponding to EGM DF. However, overall the results suggested that body surface site 22 (close to lead V1) was more closely representative of the CS activity, and site 49 (close to the posterior lower central right) was more closely representative of the left atrial activity. There was evidence of more accurate estimation of AF characteristics using additional electrodes to lead V1

    EEG based assessment of emotional wellbeing in smart environment

    Get PDF
    Abstract. Smart technologies are frequently united and automated in our everyday settings and commonplace task by linking computers and other devices. While there has been a necessity to build smart environments for an easy and comfortable life, research on measuring wellbeing in this environment becomes increasingly intensive. Emotion is one of the decisive aspects of wellbeing that encourages us to work effectively, manage, and cope with stress, and affect our physical health. This work evaluates the EEG signal to measure individuals the different emotional states in a smart space by creating a computer gaming scenario. EEG, a physiological signal which provides details on mental, physiological, and emotional states, EEG frequency bands are strongly correlated with positive and negative emotional responses. Since brain left frontal cortical area is responsible for positive emotion and the right frontal region associate, therefore, we choose two pairs of EEG electrodes F3-F4, and F7-F8 to assess the game player emotional states during the gaming situations. We measure the EEG frontal alpha asymmetry (FAA) by comparing variations in the alpha band power levels in the left and right frontal cortex, corresponding to positive and negative emotions. Our experiment outcome reveals considerable support with the emotional variance of the test participants. We note that multiple interruptions during the gaming situation create irritation to the test subjects. These findings also confirm that F3 and F4 EEG channels are the most sensitive to human emotional responses compared to F7 and F8 channels

    Polynomial matrix eigenvalue decomposition techniques for multichannel signal processing

    Get PDF
    Polynomial eigenvalue decomposition (PEVD) is an extension of the eigenvalue decomposition (EVD) for para-Hermitian polynomial matrices, and it has been shown to be a powerful tool for broadband extensions of narrowband signal processing problems. In the context of broadband sensor arrays, the PEVD allows the para-Hermitian matrix that results from the calculation of a space-time covariance matrix of the convolutively mixed signals to be diagonalised. Once the matrix is diagonalised, not only can the correlation between different sensor signals be removed but the signal and noise subspaces can also be identified. This process is referred to as broadband subspace decomposition, and it plays a very important role in many areas that require signal separation techniques for multichannel convolutive mixtures, such as speech recognition, radar clutter suppression, underwater acoustics, etc. The multiple shift second order sequential best rotation (MS-SBR2) algorithm, built on the most established SBR2 algorithm, is proposed to compute the PEVD of para-Hermitian matrices. By annihilating multiple off-diagonal elements per iteration, the MS-SBR2 algorithm shows a potential advantage over its predecessor (SBR2) in terms of the computational speed. Furthermore, the MS-SBR2 algorithm permits us to minimise the order growth of polynomial matrices by shifting rows (or columns) in the same direction across iterations, which can potentially reduce the computational load of the algorithm. The effectiveness of the proposed MS-SBR2 algorithm is demonstrated by various para-Hermitian matrix examples, including randomly generated matrices with different sizes and matrices generated from source models with different dynamic ranges and relations between the sources’ power spectral densities. A worked example is presented to demonstrate how the MS-SBR2 algorithm can be used to strongly decorrelate a set of convolutively mixed signals. Furthermore, the performance metrics and computational complexity of MS-SBR2 are analysed and compared to other existing PEVD algorithms by means of numerical examples. Finally, two potential applications of theMS-SBR2 algorithm, includingmultichannel spectral factorisation and decoupling of broadband multiple-input multiple-output (MIMO) systems, are demonstrated in this dissertation

    Improving Maternal and Fetal Cardiac Monitoring Using Artificial Intelligence

    Get PDF
    Early diagnosis of possible risks in the physiological status of fetus and mother during pregnancy and delivery is critical and can reduce mortality and morbidity. For example, early detection of life-threatening congenital heart disease may increase survival rate and reduce morbidity while allowing parents to make informed decisions. To study cardiac function, a variety of signals are required to be collected. In practice, several heart monitoring methods, such as electrocardiogram (ECG) and photoplethysmography (PPG), are commonly performed. Although there are several methods for monitoring fetal and maternal health, research is currently underway to enhance the mobility, accuracy, automation, and noise resistance of these methods to be used extensively, even at home. Artificial Intelligence (AI) can help to design a precise and convenient monitoring system. To achieve the goals, the following objectives are defined in this research: The first step for a signal acquisition system is to obtain high-quality signals. As the first objective, a signal processing scheme is explored to improve the signal-to-noise ratio (SNR) of signals and extract the desired signal from a noisy one with negative SNR (i.e., power of noise is greater than signal). It is worth mentioning that ECG and PPG signals are sensitive to noise from a variety of sources, increasing the risk of misunderstanding and interfering with the diagnostic process. The noises typically arise from power line interference, white noise, electrode contact noise, muscle contraction, baseline wandering, instrument noise, motion artifacts, electrosurgical noise. Even a slight variation in the obtained ECG waveform can impair the understanding of the patient's heart condition and affect the treatment procedure. Recent solutions, such as adaptive and blind source separation (BSS) algorithms, still have drawbacks, such as the need for noise or desired signal model, tuning and calibration, and inefficiency when dealing with excessively noisy signals. Therefore, the final goal of this step is to develop a robust algorithm that can estimate noise, even when SNR is negative, using the BSS method and remove it based on an adaptive filter. The second objective is defined for monitoring maternal and fetal ECG. Previous methods that were non-invasive used maternal abdominal ECG (MECG) for extracting fetal ECG (FECG). These methods need to be calibrated to generalize well. In other words, for each new subject, a calibration with a trustable device is required, which makes it difficult and time-consuming. The calibration is also susceptible to errors. We explore deep learning (DL) models for domain mapping, such as Cycle-Consistent Adversarial Networks, to map MECG to fetal ECG (FECG) and vice versa. The advantages of the proposed DL method over state-of-the-art approaches, such as adaptive filters or blind source separation, are that the proposed method is generalized well on unseen subjects. Moreover, it does not need calibration and is not sensitive to the heart rate variability of mother and fetal; it can also handle low signal-to-noise ratio (SNR) conditions. Thirdly, AI-based system that can measure continuous systolic blood pressure (SBP) and diastolic blood pressure (DBP) with minimum electrode requirements is explored. The most common method of measuring blood pressure is using cuff-based equipment, which cannot monitor blood pressure continuously, requires calibration, and is difficult to use. Other solutions use a synchronized ECG and PPG combination, which is still inconvenient and challenging to synchronize. The proposed method overcomes those issues and only uses PPG signal, comparing to other solutions. Using only PPG for blood pressure is more convenient since it is only one electrode on the finger where its acquisition is more resilient against error due to movement. The fourth objective is to detect anomalies on FECG data. The requirement of thousands of manually annotated samples is a concern for state-of-the-art detection systems, especially for fetal ECG (FECG), where there are few publicly available FECG datasets annotated for each FECG beat. Therefore, we will utilize active learning and transfer-learning concept to train a FECG anomaly detection system with the least training samples and high accuracy. In this part, a model is trained for detecting ECG anomalies in adults. Later this model is trained to detect anomalies on FECG. We only select more influential samples from the training set for training, which leads to training with the least effort. Because of physician shortages and rural geography, pregnant women's ability to get prenatal care might be improved through remote monitoring, especially when access to prenatal care is limited. Increased compliance with prenatal treatment and linked care amongst various providers are two possible benefits of remote monitoring. If recorded signals are transmitted correctly, maternal and fetal remote monitoring can be effective. Therefore, the last objective is to design a compression algorithm that can compress signals (like ECG) with a higher ratio than state-of-the-art and perform decompression fast without distortion. The proposed compression is fast thanks to the time domain B-Spline approach, and compressed data can be used for visualization and monitoring without decompression owing to the B-spline properties. Moreover, the stochastic optimization is designed to retain the signal quality and does not distort signal for diagnosis purposes while having a high compression ratio. In summary, components for creating an end-to-end system for day-to-day maternal and fetal cardiac monitoring can be envisioned as a mix of all tasks listed above. PPG and ECG recorded from the mother can be denoised using deconvolution strategy. Then, compression can be employed for transmitting signal. The trained CycleGAN model can be used for extracting FECG from MECG. Then, trained model using active transfer learning can detect anomaly on both MECG and FECG. Simultaneously, maternal BP is retrieved from the PPG signal. This information can be used for monitoring the cardiac status of mother and fetus, and also can be used for filling reports such as partogram

    Application of Signal Advance Technology to Electrophysiology

    Get PDF
    Medical instrumentation used in diagnosis and treatment relies on the accurate detection and processing of various physiological events and signals. While signal detection technology has improved greatly in recent years, there remain inherent delays in signal detection/ processing. These delays may have significant negative clinical consequences during various pathophysiological events. Reducing or eliminating such delays would increase the ability to provide successful early intervention in certain disorders thereby increasing the efficacy of treatment. In recent years, a physical phenomenon referred to as Negative Group Delay (NGD), demonstrated in simple electronic circuits, has been shown to temporally advance the detection of analog waveforms. Specifically, the output is temporally advanced relative to the input, as the time delay through the circuit is negative. The circuit output precedes the complete detection of the input signal. This process is referred to as signal advance (SA) detection. An SA circuit model incorporating NGD was designed, developed and tested. It imparts a constant temporal signal advance over a pre-specified spectral range in which the output is almost identical to the input signal (i.e., it has minimal distortion). Certain human patho-electrophysiological events are good candidates for the application of temporally-advanced waveform detection. SA technology has potential in early arrhythmia and epileptic seizure detection and intervention. Demonstrating reliable and consistent temporally advanced detection of electrophysiological waveforms may enable intervention with a pathological event (much) earlier than previously possible. SA detection could also be used to improve the performance of neural computer interfaces, neurotherapy applications, radiation therapy and imaging. In this study, the performance of a single-stage SA circuit model on a variety of constructed input signals, and human ECGs is investigated. The data obtained is used to quantify and characterize the temporal advances and circuit gain, as well as distortions in the output waveforms relative to their inputs. This project combines elements of physics, engineering, signal processing, statistics and electrophysiology. Its success has important consequences for the development of novel interventional methodologies in cardiology and neurophysiology as well as significant potential in a broader range of both biomedical and non-biomedical areas of application
    corecore