2,235 research outputs found

    Indirect Field Oriented Control of Induction Motors is Robustly Globally Stable

    Get PDF
    Field orientation, in one of its many forms, is an established control method for high dynamic performance AC drives. In particular, for induction motors, indirect fieldoriented control is a simple and highly reliable scheme which has become the de facto industry standard. In spite of its widespread popularity no rigorous stability proof for this controller was available in the literature. In a recent paper (Ortega et al, 1995) [Ortega, R., D. Taoutaou, R. Rabinovici and J. P. Vilain (1995). On field oriented and passivity-based control of induction motors: downward compatibility. In Proc. IFAC NOLCOS Conf., Tahoe City, CA.] we have shown that, in speed regulation tasks with constant load torque and current-fed machines, indirect field-oriented control is globally asymptotically stable provided the motor rotor resistance is exactly known. It is well known that this parameter is subject to significant changes during the machine operation, hence the question of the robustness of this stability result remained to be established. In this paper we provide some answers to this question. First, we use basic input-output theory to derive sufficient conditions on the motor and controller parameters for global boundedness of all solutions. Then, we give necessary and sufficient conditions for the uniqueness of the equilibrium point of the (nonlinear) closed loop, which interestingly enough allows for a 200% error in the rotor resistance estimate. Finally, we give conditions on the motor and controller parameters, and the speed and rotor flux norm reference values that insure (global or local) asymptotic stability or instability of the equilibrium. This analysis is based on a nonlinear change of coordinates and classical Lyapunov stability theory

    To develop an efficient variable speed compressor motor system

    Get PDF
    This research presents a proposed new method of improving the energy efficiency of a Variable Speed Drive (VSD) for induction motors. The principles of VSD are reviewed with emphasis on the efficiency and power losses associated with the operation of the variable speed compressor motor drive, particularly at low speed operation.The efficiency of induction motor when operated at rated speed and load torque is high. However at low load operation, application of the induction motor at rated flux will cause the iron losses to increase excessively, hence its efficiency will reduce dramatically. To improve this efficiency, it is essential to obtain the flux level that minimizes the total motor losses. This technique is known as an efficiency or energy optimization control method. In practice, typical of the compressor load does not require high dynamic response, therefore improvement of the efficiency optimization control that is proposed in this research is based on scalar control model.In this research, development of a new neural network controller for efficiency optimization control is proposed. The controller is designed to generate both voltage and frequency reference signals imultaneously. To achieve a robust controller from variation of motor parameters, a real-time or on-line learning algorithm based on a second order optimization Levenberg-Marquardt is employed. The simulation of the proposed controller for variable speed compressor is presented. The results obtained clearly show that the efficiency at low speed is significant increased. Besides that the speed of the motor can be maintained. Furthermore, the controller is also robust to the motor parameters variation. The simulation results are also verified by experiment

    Development and Implementation of Some Controllers for Performance Enhancement and Effective Utilization of Induction Motor Drive

    Get PDF
    The technological development in the field of power electronics and DSP technology is rapidly changing the aspect of drive technology. Implementations of advanced control strategies like field oriented control, linearization control, etc. to AC drives with variable voltage, and variable frequency source is possible because of the advent of high modulating frequency PWM inverters. The modeling complexity in the drive system and the subsequent requirement for modern control algorithms are being easily taken care by high computational power, low-cost DSP controllers. The present work is directed to study, design, development, and implementation of various controllers and their comparative evaluations to identify the proper controller for high-performance induction motor (IM) drives. The dynamic modeling for decoupling control of IM is developed by making the flux and torque decoupled. The simulation is carried out in the stationary reference frame with linearized control based on state-space linearization technique. Further, comprehensive and systematic design procedures are derived to tune the PI controllers for both electrical and mechanical subsystems. However, the PI-controller performance is not satisfactory under various disturbances and system uncertainties. Also, precise mathematical model, gain values, and continuous tuning are required for the controller design to obtain high performance. Thus, to overcome these drawbacks, an adapted control strategy based on Adaptive Neuro-Fuzzy Inference System (ANFIS) based controller is developed and implemented in real-time to validate different control strategies. The superiority of the proposed controller is analyzed and is contrasted with the conventional PI controller-based linearized IM drive. The simplified neuro-fuzzy control (NFC) integrates the concept of fuzzy logic and neural network structure like conventional NFC, but it has the advantages of simplicity and improved computational efficiency over conventional NFC as the single input introduced here is an error instead of two inputs error and change in error as in conventional NFC. This structure makes the proposed NFC robust and simple as compared to conventional NFC and thus, can be easily applied to real-time industrial applications. The proposed system incorporated with different control methods is also validated with extensive experimental results using DSP2812. The effectiveness of the proposed method using feedback linearization of IM drive is investigated in simulation as well as in experiment with different working modes. It is evident from the comparative results that the system performance is not deteriorated using proposed simplified NFC as compared to the conventional NFC, rather it shows superior performance over PI-controller-based drive. A hybrid fuel cell (FC) supply system to deliver the power demanded by the feedback linearization (FBL) based IM drive is designed and implemented. The modified simple hybrid neuro-fuzzy sliding-mode control (NFSMC) incorporated with the intuitive FBL substantially reduces torque chattering and improves speed response, giving optimal drive performance under system uncertainties and disturbances. This novel technique also has the benefit of reduced computational burden over conventional NFSMC and thus, suitable for real-time industrial applications. The parameters of the modified NFC is tuned by an adaptive mechanism based on sliding-mode control (SMC). A FC stack with a dc/dc boost converter is considered here as a separate external source during interruption of main supply for maintaining the supply to the motor drive control through the inverter, thereby reducing the burden and average rating of the inverter. A rechargeable battery used as an energy storage supplements the FC during different operating conditions of the drive system. The effectiveness of the proposed method using FC-based linearized IM drive is investigated in simulation, and the efficacy of the proposed controller is validated in real-time. It is evident from the results that the system provides optimal dynamic performance in terms of ripples, overshoot, and settling time responses and is robust in terms of parameters variation and external load

    Estimation of rotor flux of an induction machine

    Get PDF
    The objective of this dissertation is to estimate rotor flux of an IM. Some of the material is focused on the functional block of the IM i.e. Torque estimator, Speed estimator etc. while a subsequent part deals with estimation of rotor flux. The dissertation is organized as follows:Chapter 1 describes background information of the machines then it focuses on the methodology how on to approach the task on a particular time with the help of Gantt chart.Chapter 2 presents the basic principals of rotating magnetic field of the IM and asserts brief overview of the AC machines. Later it talks about different kinds of IM rotors suggesting which one is good. It is crucial to start with good and appropriate reviews which were verified by numerous journals. Literature review is presented by analysing the previous work. (Busawan et al., 2001) summarises that a nonlinear observers for the estimation of the rotor flux and the load torque in an induction motor. The observers are designed on the basis of the standard alpha - beta Park's model. Finally, fuzzy logic is mentioned in more detailed way and Membership functions were also discussedChapter 3 explains the dynamic model of induction machine plant and the model was presented. Then the model is analysed, developed in MATLAB-SIMULINK which was discussed in Chapter 4. By considering following assumptions, dynamic model is implemented i.e. it should be symmetrical two-pole, three phase windings. Slotting effects are neglected, Permeability of the iron part is infinite, and iron losses are neglected. Dynamic d-q model and Axes transformation is implemented on stationary reference frame (a-b-c). Lastly torque equation is derived.Chapter 4 is the heart of this project by scrutinizing the model thoroughly and by introducing fuzzy controller logic using MATLAB-SIMULINK; simulations are performed to estimate the functional block such as torque, speed, flux, resistance with and without fuzzy logic. Results were obtained for different blocks and the m-file, DTC, Flux table were obtained and presented in the Appendixes.Chapter 5 concludes the simulation results and concentrates mainly on the future direction what more can be done to improve the platform in a more efficient manner

    Methods of resistance estimation in permanent magnet synchronous motors for real-time thermal management

    Get PDF
    Real-time thermal management of electrical ma- chines relies on sufficiently accurate indicators of internal tem- perature. One indicator of temperature in a permanent-magnet synchronous motor (PMSM) is the stator winding resistance. Detection of PMSM winding resistance in the literature has been made on machines with relatively high resistances, where the resistive voltage vector is significant under load. This paper describes two techniques which can be applied to detect the winding resistance, through ‘Fixed Angle’ and ‘Fixed Mag- nitude’ current injection. Two further methods are described which discriminate injected current and voltages from motoring currents and voltages: ‘Unipolar’ and ‘Bipolar’ separation. These enable the resistance to be determined, and hence the winding temperature in permanent-magnet machines. These methods can be applied under load, and in a manner that does not disturb motor torque or speed. The method distinguishes between changes in the electro-motive force (EMF) constant and the resistive voltage. This paper introduces the techniques, whilst a companion paper covers the application of one of the methods to a PMSM drive system

    A high performance PWM inverter voltage-fed induction machines drive with an alternative strategy for speed control

    Get PDF
    In this paper, the method of behaviour model control is applied to an induction motor with its mechanical load in order to increase the robustness of the vector control and to keep its performances despite the presence of perturbations (parameters variations, abrupt load variations, etc). The idea of the proposed control is interesting and useful. It induces adding supplementary control inputs, which yield the process to follow the model. The distinguished feature of this control design is that it achieves the same performances as the Field Oriented Control without the need for heavy and expensive gain tuning. The proposed strategy minimizes the energy used for the control and ensures the stabilization and excellent tracking performance of the system. Simplicity of the method, minimization of the required energy and the elimination of the need for gain tuning are the main positive features of the proposed approach

    A PI/Backstepping Approach for Induction Motor Drives Robust Control

    No full text
    International audienceThis paper presents a robust control design procedure for induction motor drives in case of modeling errors and unknown load torque. The control law is based on the combination of nonlinear PI controllers and a backstepping methodology. More precisely, the controllers are determined by imposing flux-speed tracking in two steps and by using appropriate PI gains that are nonlinear functions of the system state. A comparative study between the proposed PI/Backstepping approach and the feedback linearizing control is made by realistic simulations including load torque changes, parameter variations and measurement noises. Flux-speed tracking results show the proposed method effectiveness in presence of strong disturbances

    Experiment-based Comparative Analysis of Nonlinear Speed Control Methods for Induction Motors

    Get PDF
    Field-oriented control (FOC) for induction motors is widely used in industrial applications. By using a fast and accurate torque controller based on a stator current controller it is possible to flexibly implement advanced speed control methods to achieve proper performance both in transient and steady-state states. In this study, a deadbeat controller was used for the current loop. The nonlinear methods used for the outer loop controller were backstepping, flatness-based control, and exact feedback linearization with state derivative. The dynamic responses of these three controls were compared through various experimental results. The advantages and disadvantages of the different control structures were analyzed and evaluated in detail. Based on this evaluation, an appropriate scheme can be specified when deployed in practice
    corecore