7 research outputs found

    New Approach for Temporal Stability Evaluation of Pseudo-Invariant Calibration Sites (PICS)

    Get PDF
    Pseudo-Invariant Calibration Sites (PICS) are one of the most popular methods for in-flight vicarious radiometric calibration of Earth remote sensing satellites. The fundamental question of PICS temporal stability has not been adequately addressed. However, the main purpose of this work is to evaluate the temporal stability of a few PICS using a new approach. The analysis was performed over six PICS (Libya 1, Libya 4, Niger 1, Niger 2, Egypt 1 and Sudan 1). The concept of a Virtual Constellation was developed to provide greater temporal coverage and also to overcome the dependence limitation of any specific characteristic derived from one particular sensor. TOA reflectance data from four sensors consistently demonstrating stable calibration to within 5%the Landsat 7 ETM+ (Enhanced Thematic Mapper Plus), Landsat 8 OLI (Operational Land Imager), Terra MODIS (Moderate Resolution Imaging Spectroradiometer) and Sentinel-2A MSI (Multispectral Instrument)were merged into a seamless dataset. Instead of using the traditional method of trend analysis (Students T test), a nonparametric Seasonal Mann-Kendall test was used for determining the PICS stability. The analysis results indicate that Libya 4 and Egypt 1 do not exhibit any monotonic trend in six reflective solar bands common to all of the studied sensors, indicating temporal stability. A decreasing monotonic trend was statistically detected in all bands, except SWIR 2, for Sudan 1 and the Green and Red bands for Niger 1. An increasing trend was detected in the Blue band for Niger 2 and the NIR band for Libya 1. These results do not suggest abandoning PICS as a viable calibration source. Rather, they indicate that PICS temporal stability cannot be assumed and should be regularly monitored as part of the sensor calibration process

    New Approach for Temporal Stability Evaluation of Pseudo-Invariant Calibration Sites (PICS)

    Get PDF
    Pseudo-Invariant Calibration Sites (PICS) are one of the most popular methods for in-flight vicarious radiometric calibration of Earth remote sensing satellites. The fundamental question of PICS temporal stability has not been adequately addressed. However, the main purpose of this work is to evaluate the temporal stability of a few PICS using a new approach. The analysis was performed over six PICS (Libya 1, Libya 4, Niger 1, Niger 2, Egypt 1 and Sudan 1). The concept of a “Virtual Constellation” was developed to provide greater temporal coverage and also to overcome the dependence limitation of any specific characteristic derived from one particular sensor. TOA reflectance data from four sensors consistently demonstrating “stable” calibration to within 5%—the Landsat 7 ETM+ (Enhanced Thematic Mapper Plus), Landsat 8 OLI (Operational Land Imager), Terra MODIS (Moderate Resolution Imaging Spectroradiometer) and Sentinel-2A MSI (Multispectral Instrument)–were merged into a seamless dataset. Instead of using the traditional method of trend analysis (Student’s T test), a nonparametric Seasonal Mann-Kendall test was used for determining the PICS stability. The analysis results indicate that Libya 4 and Egypt 1 do not exhibit any monotonic trend in six reflective solar bands common to all of the studied sensors, indicating temporal stability. A decreasing monotonic trend was statistically detected in all bands, except SWIR 2, for Sudan 1 and the Green and Red bands for Niger 1. An increasing trend was detected in the Blue band for Niger 2 and the NIR band for Libya 1. These results do not suggest abandoning PICS as a viable calibration source. Rather, they indicate that PICS temporal stability cannot be assumed and should be regularly monitored as part of the sensor calibration process

    Detection of Change Points in Pseudo-Invariant Calibration Sites Time Series Using Multi-Sensor Satellite Imagery

    Get PDF
    The remote sensing community has extensively used Pseudo-Invariant Calibration Sites (PICS) to monitor the long-term in-flight radiometric calibration of Earth-observing satellites. The use of the PICS has an underlying assumption that these sites are invariant over time. However, the site’s temporal stability has not been assured in the past. This work evaluates the temporal stability of PICS by not only detecting the trend but also locating significant shifts (change points) lying behind the time series. A single time series was formed using the virtual constellation approach in which multiple sensors data were combined for each site to achieve denser temporal coverage and overcome the limitation of dependence related to a specific sensor. The sensors used for this work were selected based on radiometric calibration uncertainty and availability of the data: operational land imager (Landsat-8), enhanced thematic mapper (Landsat-7), moderate resolution imaging spectroradiometer (Terra and Aqua), and multispectral instrument (Sentinel-2A). An inverse variance weighting method was applied to the Top-of- Atmosphere (TOA) reflectance time series to reveal the underlying trend. The sequential Mann–Kendall test was employed upon the weighted TOA reflectance time-series recorded over 20 years to detect abrupt changes for six reflective bands. Statistically significant trends and abrupt changes have been detected for all sites, but the magnitude of the trends (maximum of 0.215% change in TOA reflectance per year) suggest that these sites are not changing substantially over time. Hence, it can be stated that despite minor changes in all evaluated PICS, they can be used for radiometric calibration of optical remote sensing sensors. The new approach provides useful results by revealing underlying trends and providing a better understanding of PICS\u27 stability

    Hyperspectral Empirical Absolute Calibration Model Using Libya 4 Pseudo-Invariant Calibration Site

    Get PDF
    The objective of this paper is to find an empirical hyperspectral absolute calibration model using Libya 4 pseudo-invariant calibration site (PICS). The approach involves using the Landsat 8 (L8) Operational Land Imager (OLI) as the reference radiometer and using Earth Observing One (EO-1) Hyperion, with a spectral resolution of 10 nm as a hyperspectral source. This model utilizes data from a region of interest (ROI) in an “optimal region” of 3% temporal, spatial, and spectral stability within the Libya 4 PICS. It uses an improved, simple, empirical, hyperspectral Bidirectional Reflectance Distribution function (BRDF) model accounting for four angles: solar zenith and azimuth, and view zenith and azimuth angles. This model can perform absolute calibration in 1 nm spectral resolution by predicting TOA reflectance in all existing spectral bands of the sensors. The resultant model was validated with image data acquired from satellite sensors such as Landsat 7, Sentinel 2A, and Sentinel 2B, Terra MODIS, Aqua MODIS, from their launch date to 2020. These satellite sensors differ in terms of the width of their spectral band-pass, overpass time, off-nadir viewing capabilities, spatial resolution, and temporal revisit time, etc. The result demonstrates the efficacy of the proposed model has an accuracy of the order of 3% with a precision of about 3% for the nadir viewing sensors (with view zenith angle up to 5°) used in the study. For the off-nadir viewing satellites with view zenith angle up to 20°, it can have an estimated accuracy of 6% and precision of 4%

    Vicarious Methodologies to Assess and Improve the Quality of the Optical Remote Sensing Images: A Critical Review

    Get PDF
    Over the past decade, number of optical Earth observing satellites performing remote sensing has increased substantially, dramatically increasing the capability to monitor the Earth. The quantity of remote sensing satellite increase is primarily driven by improved technology, miniaturization of components, reduced manufacturing, and launch cost. These satellites often lack on-board calibrators that a large satellite utilizes to ensure high quality (e.g., radiometric, geometric, spatial quality, etc.) scientific measurement. To address this issue, this work presents “best” vicarious image quality assessment and improvement techniques for those kinds of optical satellites which lacks on-board calibration system. In this article, image quality categories have been explored, and essential quality parameters (e.g., absolute and relative calibration, aliasing, etc.) have been identified. For each of the parameters, appropriate characterization methods are identified along with its specifications or requirements. In cases of multiple methods, recommendation has been made based-on the strengths and weaknesses of each method. Furthermore, processing steps have been presented, including examples. Essentially, this paper provides a comprehensive study of the criteria that needs to be assessed to evaluate remote sensing satellite data quality, and best vicarious methodologies to evaluate identified quality parameters such as coherent noise, ground sample distance, etc

    Armonización de datos de satélite mediante zonas homogéneas

    Get PDF
    La calibración radiométrica de los sensores es un factor clave en la interoperabilidad de los datos, permitiendo asegurar su calidad científica y la comparación de los mismos entre sensores. Actualmente, la gran mayoría de satélites no poseen la instrumentación necesaria para realizar calibración on board por su elevado coste económico y por la simplicidad en el diseño del satélite lo que se une a la problemática de realizar medidas In-Situ en determinadas localizaciones de la Tierra. Por ello, la utilización de técnicas de calibración de manera indirecta tomando como referencia otros sensores permite una calibración radiométrica absoluta, de forma rápida, precisa y con un coste económico bajo. En esta tesis doctoral, se presenta una metodología de armonización de datos de satélite a partir de zonas homogéneas, aplicable a las dos metodologías fundamentales para la calibración radiométrica de manera indirecta, como son Simultaneous Nadir Overpass (SNOs) y Pseudo-Invariant Calibration Sites (PICS).Departamento de Física AplicadaDoctorado en Físic
    corecore