2 research outputs found
Motion and deformation estimation of cardiac ultrasound sequences using an anatomical B-spline transformation model
We present a novel method for tracking myocardial motion in 2D ultrasound sequences based on non-rigid registration using an anatomical free-form deformation (AFFD) model where the basis functions are locally oriented along the radial and circumferential direction of the left ventricle (LV). This formulation allows us to model the LV motion more naturally compared to previously proposed FFD's defined on a regular Cartesian grid (CFFD). In this paper we compare the performance of the AFFD against the CFFD model in an in-vivo setting. Short-axis images were acquired in five open-chest sheep using sonomicrometry as ground-truth deformation estimates. We demonstrated that regional end-systolic strain values assessed with the AFFD model are comparable with CFFD, while also displaying a statistically lower drift at the end of the cardiac cycle and a better agreement with a manual end-systolic reference. Furthermore, tracking using AFFD was visually more appealing to clinical experts
Cardiac motion and deformation estimation in tagged magnetic resonance imaging
Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Electrónica Médica)Cardiovascular diseases are the main cause of death in Europe, with an estimate
of 4.3 million deaths each year. The assessment of the regional wall deformation is a
relevant clinical indicator, and can be used to detect several cardiac lesions. Nowadays,
this study can be performed using several image modalities. In the current thesis, we
focus on tagged Magnetic Resonance imaging (t-MRI) technique. Such technique
allows acquiring images with tags on the myocardium, which deform with the muscle.
The present thesis intends to assess the left ventricle (LV) deformation using
radial and circumferential strain. To compute such strain values, both endo- and
epicardial contours of the LV are required.
As such, a new framework to automatically assess the LV function is proposed.
This framework presents: (i) an automatic segmentation technique, based on a tag
suppression strategy followed by an active contour segmentation method, and (ii) a
tracking approach to extract myocardial deformation, based on a non-rigid registration
method. The automatic segmentation uses the B-spline Explicit Active Surface
framework, which was previously applied in ultra-sound and cine-MRI images. In both
cases, a real-time and accurate contour was achieved. Regarding the registration step,
starting from a state-of-art approach, termed sequential 2D, we suggest a new method
(termed sequential 2D+t), where the temporal information is included on the model.
The tracking methods were first tested on synthetic data to study the registration
parameters influence. Furthermore, the proposed and original methods were applied on
porcine data with myocardial ischemia. Both methods were able to detect dysfunctional
regions. A comparison between the strain curve in the sequential 2D and sequential
2D+t strategies was also shown. As conclusion, a smoothing effect in the strain curve
was detected in the sequential 2D+t strategy. The validation of the segmentation
approach uses a human dataset. A comparison between the manual contour and the
proposed segmentation method results was performed. The results, suggest that
proposed method has an acceptable performance, removing the tedious task related with
manual segmentation and the intra-observer variability. Finally, a comparison between
the proposed framework and the currently available commercial software was
performed. The commercial software results were obtained from core-lab analysis. An
acceptable result (r = 0.601) was achieved when comparing the strain peak values.
Importantly, the proposed framework appears to present a more acceptable result.As doenças cardiovasculares são a principal causa de morte na Europa, com
aproximadamente 4.7 milhões de mortes por ano. A avaliação da deformação do
miocárdio a um nível local é um importante indicador clínico e pode ser usado para a
deteção de lesões cardíacas. Este estudo é normalmente realizado usando várias
modalidades de imagem médica. Nesta tese, a Resonância Magnética (RM) marcada foi
a técnica selecionada. Estas imagens têm marcadores no músculo cardíaco, os quais se
deformam com o miocárdio e podem ser usados para o estudo da deformação cardíaca.
Nesta tese, pretende-se estudar a deformação radial e circunferencial do
ventrículo esquerdo (VE). Assim, um contorno do endo- e epicárdio no VE é essencial.
Desta forma, uma ferramenta para o estudo da deformação do VE foi
desenvolvida. Esta possui: (i) um método de segmentação automático, usando uma
estratégia de supressão dos marcadores, seguido de uma segmentação c um contorno
ativo, e (ii) um método de tracking para determinação da deformação cardíaca, baseado
em registo não rígido. A segmentação automática utiliza a ferramenta B-spline Explicit
Active Surface, que foi previamente aplicada em imagens de ultrassons e cine-RM. Em
ambos os casos, uma segmentação em tempo real e com elevada exatidão foi alcançada.
Vários esquemas de registo foram apresentados. Neste ponto, começando com uma
técnica do estado da arte (designada de sequencial 2D), uma nova metodologia foi
proposta (sequencial 2D+t), onde a informação temporal é incorporada no modelo.
De forma a analisar a influência dos parâmetros do registo, estes foram
estudados num dataset sintético. De seguida, os diferentes esquemas de registo foram
testados num dataset suíno com isquemia. Ambos os métodos foram capazes de detetar
as regiões disfuncionais. De igual forma, utilizando as curvas de deformação obtidas
para cada um dos métodos propostos, foi possível observar uma suavização na direção
temporal para o método sequencial 2D+t. Relativamente à segmentação, esta foi
validada com um dataset humano. Um contorno manual foi comparado com o obtido
pelo método proposto. Os resultados sugerem que a nova estratégia é aceitável, sendo
mais rápida do que a realização de um contorno manual e eliminando a variabilidade
entre observadores. Por fim, realizou-se uma comparação entre a ferramenta proposta e
um software comercial (com análise de core-lab). A comparação entre os valores de
pico da deformação exibe uma correlação plausível (r=0.601). Contudo, é importante
notar, que a nova ferramenta tende a apresentar um resultado mais aceitável