12,661 research outputs found

    The multitasking framework: the effects of increasing workload on acute psychobiological stress reactivity

    Get PDF
    A variety of techniques exist for eliciting acute psychological stress in the laboratory; however, they vary in terms of their ease of use, reliability to elicit consistent responses and the extent to which they represent the stressors encountered in everyday life. There is, therefore, a need to develop simple laboratory techniques that reliably elicit psychobiological stress reactivity that are representative of the types of stressors encountered in everyday life. The multitasking framework is a performance-based, cognitively demanding stressor, representative of environments where individuals are required to attend and respond to several different stimuli simultaneously with varying levels of workload. Psychological (mood and perceived workload) and physiological (heart rate and blood pressure) stress reactivity was observed in response to a 15-min period of multitasking at different levels of workload intensity in a sample of 20 healthy participants. Multitasking stress elicited increases in heart rate and blood pressure, and increased workload intensity elicited dose–response increases in levels of perceived workload and mood. As individuals rarely attend to single tasks in real life, the multitasking framework provides an alternative technique for modelling acute stress and workload in the laboratory

    Embedded FIR filter design for real-time refocusing using a standard plenoptic video camera

    Get PDF
    Copyright 2014 Society of Photo-Optical Instrumentation Engineers and IS&T—The Society for Imaging Science and Technology. One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited.A novel and low-cost embedded hardware architecture for real-time refocusing based on a standard plenoptic camera is presented in this study. The proposed layout design synthesizes refocusing slices directly from micro images by omitting the process for the commonly used sub-aperture extraction. Therefore, intellectual property cores, containing switch controlled Finite Impulse Response (FIR) filters, are developed and applied to the Field Programmable Gate Array (FPGA) XC6SLX45 from Xilinx. Enabling the hardware design to work economically, the FIR filters are composed of stored product as well as upsampling and interpolation techniques in order to achieve an ideal relation between image resolution, delay time, power consumption and the demand of logic gates. The video output is transmitted via High-Definition Multimedia Interface (HDMI) with a resolution of 720p at a frame rate of 60 fps conforming to the HD ready standard. Examples of the synthesized refocusing slices are presented

    Recommendations for the Health Examination Surveys in Europe

    Get PDF

    Proximal aortic stiffening in Turner patients may be present before dilation can be detected : a segmental functional MRI study

    Get PDF
    Background: To study segmental structural and functional aortic properties in Turner syndrome (TS) patients. Aortic abnormalities contribute to increased morbidity and mortality of women with Turner syndrome. Cardiovascular magnetic resonance (CMR) allows segmental study of aortic elastic properties. Method: We performed Pulse Wave Velocity (PWV) and distensibility measurements using CMR of the thoracic and abdominal aorta in 55 TS-patients, aged 13-59y, and in a control population (n = 38; 12-58y). We investigated the contribution of TS on aortic stiffness in our entire cohort, in bicuspid (BAV) versus tricuspid (TAV) aortic valve-morphology subgroups, and in the younger and older subgroups. Results: Differences in aortic properties were only seen at the most proximal aortic level. BAV Turner patients had significantly higher PWV, compared to TAV Turner (p = 0.014), who in turn had significantly higher PWV compared to controls (p = 0.010). BAV Turner patients had significantly larger ascending aortic (AA) luminal area and lower AA distensibility compared to both controls (all p < 0.01) and TAV Turner patients. TAV Turner had similar AA luminal areas and AA distensibility compared to Controls. Functional changes are present in younger and older Turner subjects, whereas ascending aortic dilation is prominent in older Turner patients. Clinically relevant dilatation (TAV and BAV) was associated with reduced distensibility. Conclusion: Aortic stiffening and dilation in TS affects the proximal aorta, and is more pronounced, although not exclusively, in BAV TS patients. Functional abnormalities are present at an early age, suggesting an aortic wall disease inherent to the TS. Whether this increased stiffness at young age can predict later dilatation needs to be studied longitudinally

    Apparatus and method for processing Korotkov sounds

    Get PDF
    A Korotkov sound processor, used in a noninvasive automatic blood measuring system where the brachial artery is occluded by an inflatable cuff, is disclosed. The Korotkoff sound associated with the systolic event is determined when the ratio of the absolute value of a voltage signal, representing Korotkov sounds in the range of 18 to 26 Hz to a maximum absolute peak value of the unfiltered signals, first equals or exceeds a value of 0.45. Korotkov sound associated with the diastolic event is determined when a ratio of the voltage signal of the Korotkov sounds in the range of 40 to 60 Hz to the absolute peak value of such signals within a single measurement cycle first falls below a value of 0.17. The processor signals the occurrence of the systolic and diastolic events and these signals can be used to control a recorder to record pressure values for these events

    Treatment of atherosclerotic renovascular hypertension: review of observational studies and a meta-analysis of randomized clinical trials.

    Get PDF
    open9Atherosclerotic renal artery stenosis can cause ischaemic nephropathy and arterial hypertension. We herein review the observational and randomized clinical trials (RCTs) comparing medical and endovascular treatment for control of hypertension and renal function preservation. Using the Population Intervention Comparison Outcome (PICO) strategy, we identified the relevant studies and performed a novel meta-analysis of all RCTs to determine the efficacy and safety of endovascular treatment when compared with medical therapy. The following outcomes were examined: baseline follow-up difference in mean systolic and diastolic blood pressure (BP), serum creatinine, number of drugs at follow-up, incident events (heart failure, stroke, and worsening renal function), mortality, cumulative relative risk of heart failure, stroke, and worsening renal function. Seven studies comprising a total of 2155 patients (1741 available at follow-up) were considered, including the recently reported CORAL Study. Compared with baseline, diastolic BP fell more at follow-up in patients in the endovascular than in the medical treatment arm (standard difference in means -0.21, 95% confidence interval (CI): -0.342 to -0.078, P = 0.002) despite a greater reduction in the mean number of antihypertensive drugs (standard difference in means -0.201, 95% CI: -0.302 to -0.1, P &lt; 0.001). At variance, follow-up changes (from baseline) of systolic BP, serum creatinine, and incident cardiovascular event rates did not differ between treatment arms. Thus, patients with atherosclerotic renal artery stenosis receiving endovascular treatment required less anti-antihypertensive drugs at follow-up than those medically treated. Notwithstanding this, they evidenced a better control of diastolic BP.openopenCaielli P;Frigo AC;Pengo MF;Rossitto G;Maiolino G;Seccia TM;Calò LA;Miotto D;Rossi GPCaielli, P; Frigo, ANNA CHIARA; Pengo, Mf; Rossitto, G; Maiolino, G; Seccia, TERESA MARIA; Calò, La; Miotto, Diego; Rossi, Gianpaol

    Treatment of denture-related stomatitis improves endothelial function assessed by flow-mediated vascular dilation

    Get PDF
    Introduction: The presence of oral inflammation has recently been linked with the pathogenesis of cardiovascular diseases. While numerous studies have described links between periodontitis and endothelial dysfunction, little is known about the influence of denture-related stomatitis (DRS) on cardiovascular risk. Therefore, the aim of this study was to determine whether the treatment of DRS can lead to improvement of the clinical measures of vascular dysfunction. Material and methods: The DRS patients were treated with a local oral antifungal agent for 3 weeks. Blood pressure, flow-mediated dilatation (FMD) and nitroglycerine-mediated vascular dilatation (NMD) were measured during three study visits: before treatment, one day and two months after conclusion of antifungal therapy. Results: Flow-mediated dilatation measurements showed significant improvement of endothelial function 2 months after treatment (FMD median 5%, 95 CI: 3–8.3 vs. 11%, 95% CI: 8.8–14.4; p &lt; 0.01), while there was no difference in control, endothelium-independent vasorelaxations (NMD; median = 15.3%, 95% CI: 10.8–19.3 vs. 12.7%, 95% CI: 10.6–15; p = 0.3). Other cardiovascular parameters such as systolic (median = 125 mm Hg; 95% CI: 116–129 vs. 120 mm Hg, 95% CI: 116–126; p = 0.1) as well as diastolic blood pressure and heart rate (median = 65.5 bpm, 95% CI: 56.7–77.7 vs. 71 bpm, 95% CI: 66.7–75; p = 0.5) did not change during or after the treatment. Conclusions: Treatment of DRS is associated with improvement of endothelial function. Since endothelial dysfunction is known to precede the development of severe cardiovascular disorders such as atherosclerosis and hypertension, patients should be more carefully screened for DRS in general dental practice, and immediate DRS treatment should be advised
    corecore