3,269 research outputs found

    Machine learning predicts lung recruitment in acute respiratory distress syndrome using single lung CT scan

    Get PDF
    Background: To develop and validate classifier models that could be used to identify patients with a high percentage of potentially recruitable lung from readily available clinical data and from single CT scan quantitative analysis at intensive care unit admission. 221 retrospectively enrolled mechanically ventilated, sedated and paralyzed patients with acute respiratory distress syndrome (ARDS) underwent a PEEP trial at 5 and 15 cmH2O of PEEP and two lung CT scans performed at 5 and 45 cmH2O of airway pressure. Lung recruitability was defined at first as percent change in not aerated tissue between 5 and 45 cmH2O (radiologically defined; recruiters: Δ45-5non-aerated tissue > 15%) and secondly as change in PaO2 between 5 and 15 cmH2O (gas exchange-defined; recruiters: Δ15-5PaO2 > 24 mmHg). Four machine learning (ML) algorithms were evaluated as classifiers of radiologically defined and gas exchange-defined lung recruiters using different models including different variables, separately or combined, of lung mechanics, gas exchange and CT data. Results: ML algorithms based on CT scan data at 5 cmH2O classified radiologically defined lung recruiters with similar AUC as ML based on the combination of lung mechanics, gas exchange and CT data. ML algorithm based on CT scan data classified gas exchange-defined lung recruiters with the highest AUC. Conclusions: ML based on a single CT data at 5 cmH2O represented an easy-to-apply tool to classify ARDS patients in recruiters and non-recruiters according to both radiologically defined and gas exchange-defined lung recruitment within the first 48 h from the start of mechanical ventilation

    Smart Mechanical Ventilators:Learning for Monitoring and Control

    Get PDF

    Understanding clinical and biological heterogeneity to advance precision medicine in paediatric acute respiratory distress syndrome

    Get PDF
    Paediatric acute respiratory distress syndrome (PARDS) is a heterogeneous clinical syndrome that is associated with high rates of mortality and long-term morbidity. Factors that distinguish PARDS from adult acute respiratory distress syndrome (ARDS) include changes in developmental stage and lung maturation with age, precipitating factors, and comorbidities. No specific treatment is available for PARDS and management is largely supportive, but methods to identify patients who would benefit from specific ventilation strategies or ancillary treatments, such as prone positioning, are needed. Understanding of the clinical and biological heterogeneity of PARDS, and of differences in clinical features and clinical course, pathobiology, response to treatment, and outcomes between PARDS and adult ARDS, will be key to the development of novel preventive and therapeutic strategies and a precision medicine approach to care. Studies in which clinical, biomarker, and transcriptomic data, as well as informatics, are used to unpack the biological and phenotypic heterogeneity of PARDS, and implementation of methods to better identify patients with PARDS, including methods to rapidly identify subphenotypes and endotypes at the point of care, will drive progress on the path to precision medicine.</p

    Predicting Responses to Mechanical Ventilation for Preterm Infants with Acute Respiratory Illness using Artificial Neural Networks

    Get PDF
    Infants born prematurely are particularly susceptible to respiratory illness due to underdeveloped lungs, which can often result in fatality. Preterm infants in acute stages of respiratory illness typically require mechanical ventilation assistance, and the efficacy of the type of mechanical ventilation and its delivery has been the subject of a number clinical studies. With recent advances in machine learning approaches, particularly deep learning, it may be possible to estimate future responses to mechanical ventilation in real‐time, based on ventilation monitoring up to the point of analysis. In this work, recurrent neural networks are proposed for predicting future ventilation parameters due to the highly nonlinear behavior of the ventilation measures of interest and the ability of recurrent neural networks to model complex nonlinear functions. The resulting application of this particular class of neural networks shows promise in its ability to predict future responses for different ventilation modes. Towards improving care and treatment of preterm newborns, further development of this prediction process for ventilation could potentially aid in important clinical decisions or studies to improve preterm infant health

    Hybrid optimization techniques based automatic artificial respiration system for corona patient

    Get PDF
    Artificial ventilation is widely used for various respiratory problems of human beings. The oxygen level of the corona patients has to be maintained for smooth breathing which is very difficult. For achieving this state, the air pressure should be controlled in the respiration system that has a piston mechanism driven by a motor. An Automatic respiration system model is designed and controller parameters are tuned using hybrid Optimization techniques. Hybrid Controllers like genetic algorithm based Fractional Order Proportional Integral Derivative controller (FOPID), Fmincon-Pattern search Algorithm based Proportional Integral Derivative (PID) controller, and Hybrid Model predictive control (MPC) – Proportional Integral Derivative (PID) controllers were designed and verified. Integral Square Error is considered as the objective function of the optimization technique to find the controller parameters. The output responses of all three hybrid controllers are compared based on the error indices, time domain specifications, set-point tracking and Convergence speed graph. The genetic algorithm-based FOPID controller gives better results when compared with the Fmincon-Pattern search Algorithm based Proportional Integral Derivative (PID) controller and Hybrid Model predictive control (MPC) – Proportional Integral Derivative (PID) for the proposed artificial ventilation system

    Reconstructing asynchrony for mechanical ventilation using a hysteresis loop virtual patient model

    Get PDF
    Background: Patient-specific lung mechanics during mechanical ventilation (MV) can be identified from measured waveforms of fully ventilated, sedated patients. However, asynchrony due to spontaneous breathing (SB) effort can be common, altering these waveforms and reducing the accuracy of identified, model-based, and patient-specific lung mechanics. Methods: Changes in patient-specific lung elastance over a pressure–volume (PV) loop, identified using hysteresis loop analysis (HLA), are used to detect the occurrence of asynchrony and identify its type and pattern. The identified HLA parameters are then combined with a nonlinear mechanics hysteresis loop model (HLM) to extract and reconstruct ventilated waveforms unaffected by asynchronous breaths. Asynchrony magnitude can then be quantified using an energy-dissipation metric, Easyn, comparing PV loop area between model-reconstructed and original, altered asynchronous breathing cycles. Performance is evaluated using both test-lung experimental data with a known ground truth and clinical data from four patients with varying levels of asynchrony. Results: Root mean square errors for reconstructed PV loops are within 5% for test-lung experimental data, and 10% for over 90% of clinical data. Easyn clearly matches known asynchrony magnitude for experimental data with RMS errors 50% for Patient 1 and 13% for Patient 2. Patient 3 only presents 20% breaths with Easyn > 10%. Patient 4 has Easyn = 0 for 96% breaths showing accuracy in a case without asynchrony. Conclusions: Experimental test-lung validation demonstrates the method’s reconstruction accuracy and generality in controlled scenarios. Clinical validation matches direct observations of asynchrony in incidence and quantifies magnitude, including cases without asynchrony, validating its robustness and potential efficacy as a clinical real-time asynchrony monitoring tool

    An AI based digital-twin for prioritizing pneumonia patient treatment

    Get PDF
    A digital-twin based three-tiered system is proposed to prioritise patients for urgent intensive care and ventilator support. The deep learning methods are used to build patient-specific digital-twins to identify and prioritise critical cases amongst severe pneumonia patients. The three-tiered strategy is proposed to generate severity indices to: 1) identify urgent cases, 2) assign critical care and mechanical ventilation, and 3) discontinue mechanical ventilation and critical care at the optimal time. The severity indices calculated in the present study are the probability of death and the probability of requiring mechanical ventilation. These enable the generation of patient prioritisation lists and facilitates the smooth flow of patients in and out of Intensive Therapy Units (ITUs). The proposed digital-twin is built on pre-trained deep learning models using data from more than 1895 pneumonia patients. The severity indices calculated in the present study are assessed using the standard benchmark of Area Under Receiving Operating Characteristic Curve (AUROC). The results indicate that the ITU and mechanical ventilation can be prioritised correctly to an AUROC value as high as 0.89. This model may be employed in its current form to COVID-19 patients, but transfer learning with COVID-19 patient data will improve the predictions. The digital-twin model developed and tested is available via accompanyingsupplementary material

    Automated Detection of Incomplete Exhalation as an Indirect Detection of Auto-PEEP on Mechanically Ventilated Adults

    Get PDF
    Auto-PEEP is auto positive end-expiratory pressure due to excessive amounts of alveolar gas produced by sustained recurrent incomplete exhalation. Incomplete exhalation occurs when the exhaled breath never reaches a flow rate of 0 L/min. The objective of this dissertation is to develop an automated detection system of auto-PEEP through incomplete exhalation as revealed by ventilator graphics for mechanically ventilated adults. Auto-PEEP can cause adverse effects if allowed to linger and if not quickly identified. An automated detection system will be instrumental in helping to quickly identify auto-PEEP. A computerized algorithm was developed to detect incomplete exhalation based on the following three parameters:1) Foi, was used to represent the value of the flow at the onset of inhalation, 2) ∆T, was used to represent the value of time difference between onset inhalation to the 0 L/min mark, and 3) slope threshold, a value set for the slope of change of flow over ∆T. Optimum parameters of the algorithm were achieved for Foi = -3 L/min, ∆T = 0.2 s, and slope threshold = 90 L-s/min. A novel data set was introduced to validate the algorithm, yielding no significant difference in true positive rates (t = 1.5, df = 12.402, p-value = 0.1408) and false positive rates (t = 1.9, df = 16.765, p-value = 0.0725) as outcomes for two-tailed t-tests comparing the novel and old data set. To determine the relationship between auto-PEEP and detection of sustained incomplete exhalation, a correlation of a linear model of the novel data set between auto-PEEP and the percentage of incomplete exhalation detection out of the existing breaths (index) was investigated. A linear model should interpret the index value that corresponds to significant auto-PEEP presence; unfortunately, no significant linear model was found between incomplete exhalation index and auto-PEEP (F1,62 = 1.67, p-value = 0.2010). However, there was a relationship between the intrinsic PEEP values and the incomplete exhalation index as functions of time. The automated detection algorithm produced by this work provides a non-invasive method of automatically detecting auto-PEEP
    • 

    corecore