177 research outputs found

    Motion analysis of a robotic assisted surgery and microsurgery system - experimental verification

    Full text link
    Motion analysis of a parallel robot assisted minimally invasive surgery/microsurgery system (PRAMiSS) and the control structures enabling it to achieve milli/micromanipulations under the constraint of moving through a fixed penetration point or so-called remote centre-of-motion (RCM) are presented in this article. Two control algorithms are proposed suitable for minimally invasive surgery (MIS) with submillimeter accuracy and for minimally invasive micro-surgery (MIMS) with submicrometer accuracy. The RCM constraint is performed without having any mechanical constraint. Control algorithms also apply orientation constraint preventing the tip to orient relative to the soft tissues due to the robot movements. Experiments were conducted to verify accuracy and effectiveness of the proposed control algorithms for MIS and MIMS operations. The experimental results demonstrate accuracy and performance of the proposed position control algorithms

    From passive tool holders to microsurgeons: safer, smaller, smarter surgical robots

    No full text

    Magnetic-Visual Sensor Fusion-based Dense 3D Reconstruction and Localization for Endoscopic Capsule Robots

    Full text link
    Reliable and real-time 3D reconstruction and localization functionality is a crucial prerequisite for the navigation of actively controlled capsule endoscopic robots as an emerging, minimally invasive diagnostic and therapeutic technology for use in the gastrointestinal (GI) tract. In this study, we propose a fully dense, non-rigidly deformable, strictly real-time, intraoperative map fusion approach for actively controlled endoscopic capsule robot applications which combines magnetic and vision-based localization, with non-rigid deformations based frame-to-model map fusion. The performance of the proposed method is demonstrated using four different ex-vivo porcine stomach models. Across different trajectories of varying speed and complexity, and four different endoscopic cameras, the root mean square surface reconstruction errors 1.58 to 2.17 cm.Comment: submitted to IROS 201

    Providing adhesion for a miniture mobile intra-abdominal device based on biomimetic principles

    Get PDF
    This paper investigates the surface adhesion characteristics required for a miniature mobile device to move around the abdominal cavity. Such a device must be capable of adhering to the tissue lining and move freely across the upper surface of the insufflated abdomen. Accordingly, the potential of utilising bioinspired solutions to facilitate wet adhesion is assessed

    Kinematic analysis of a novel 2-d.o.f. orientation device

    Get PDF
    This paper presents the development of a new parallel robot designed for helping with bone milling surgeries. The robot is a small modular wrist with 2 active degrees of freedom, and it is proposed to be used as an orientation device located at the end of a robotic arm designed for bone milling processes. A generic kinematic geometry is proposed for this device. This first article shows the developments on the workspace optimization and the analysis of the force field required to complete a reconstruction of the inferior jawbone. The singularities of the mechanism are analyzed, and the actuator selection is justified with the torque requirements and the study of the force space. The results obtained by the simulations allow building a first prototype using linear motors. Bone milling experiment video is shown as additional material

    Haptics-Enabled Teleoperation for Robotics-Assisted Minimally Invasive Surgery

    Get PDF
    The lack of force feedback (haptics) in robotic surgery can be considered to be a safety risk leading to accidental tissue damage and puncturing of blood vessels due to excessive forces being applied to tissue and vessels or causing inefficient control over the instruments because of insufficient applied force. This project focuses on providing a satisfactory solution for introducing haptic feedback in robotics-assisted minimally invasive surgical (RAMIS) systems. The research addresses several key issues associated with the incorporation of haptics in a master-slave (teleoperated) robotic environment for minimally invasive surgery (MIS). In this project, we designed a haptics-enabled dual-arm (two masters - two slaves) robotic MIS testbed to investigate and validate various single-arm as well as dual-arm teleoperation scenarios. The most important feature of this setup is the capability of providing haptic feedback in all 7 degrees of freedom (DOF) required for RAMIS (3 translations, 3 rotations and pinch motion of the laparoscopic tool). The setup also enables the evaluation of the effect of replacing haptic feedback by other sensory cues such as visual representation of haptic information (sensory substitution) and the hypothesis that surgical outcomes may be improved by substituting or augmenting haptic feedback by such sensory cues

    Experimental and theoretical analysis of a novel flexible membrane tactile sensor

    Get PDF
    In this study, we report the development of a new multi tactile sensor, capable of detecting 2D surface texture image, measuring contact-force, and identifying the difference between stiffness of sensed objects. The designed tactile sensor consists of a chamber and a membrane with a mesa structure. The detecting principle is a combination of membrane deflection and piezoresistante effects. A major advantage of the designed system is that it can be easily miniaturized and micromachined. As a result, it is suitable for using in medical applications, especially in minimally invasive surgery (MIS). © 2008 Science Publications
    corecore