161 research outputs found

    Digital mammography, cancer screening: Factors important for image compression

    Get PDF
    The use of digital mammography for breast cancer screening poses several novel problems such as development of digital sensors, computer assisted diagnosis (CAD) methods for image noise suppression, enhancement, and pattern recognition, compression algorithms for image storage, transmission, and remote diagnosis. X-ray digital mammography using novel direct digital detection schemes or film digitizers results in large data sets and, therefore, image compression methods will play a significant role in the image processing and analysis by CAD techniques. In view of the extensive compression required, the relative merit of 'virtually lossless' versus lossy methods should be determined. A brief overview is presented here of the developments of digital sensors, CAD, and compression methods currently proposed and tested for mammography. The objective of the NCI/NASA Working Group on Digital Mammography is to stimulate the interest of the image processing and compression scientific community for this medical application and identify possible dual use technologies within the NASA centers

    Hybrid Region-based Image Compression Scheme for Mamograms and Ultrasound Images

    Get PDF
    The need for transmission and archive of mammograms and ultrasound Images has dramatically increased in tele-healthcare applications. Such images require large amount of' storage space which affect transmission speed. Therefore an effective compression scheme is essential. Compression of these images. in general. laces a great challenge to compromise between the higher compression ratio and the relevant diagnostic information. Out of the many studied compression schemes. lossless . IPl. (i- LS and lossy SPII IT are found to he the most efficient ones. JPEG-LS and SI'll IT are chosen based on a comprehensive experimental study carried on a large number of mammograms and ultrasound images of different sizes and texture. The lossless schemes are evaluated based on the compression ratio and compression speed. The distortion in the image quality which is introduced by lossy methods evaluated based on objective criteria using Mean Square Error (MSE) and Peak signal to Noise Ratio (PSNR). It is found that lossless compression can achieve a modest compression ratio 2: 1 - 4: 1. bossy compression schemes can achieve higher compression ratios than lossless ones but at the price of the image quality which may impede diagnostic conclusions. In this work, a new compression approach called Ilvbrid Region-based Image Compression Scheme (IIYRICS) has been proposed for the mammograms and ultrasound images to achieve higher compression ratios without compromising the diagnostic quality. In I LYRICS, a modification for JPI; G-LS is introduced to encode the arbitrary shaped disease affected regions. Then Shape adaptive SPIT IT is applied on the remaining non region of interest. The results clearly show that this hybrid strategy can yield high compression ratios with perfect reconstruction of diagnostic relevant regions, achieving high speed transmission and less storage requirement. For the sample images considered in our experiment, the compression ratio increases approximately ten times. However, this increase depends upon the size of the region of interest chosen. It is also föund that the pre-processing (contrast stretching) of region of interest improves compression ratios on mammograms but not on ultrasound images

    Significant medical image compression techniques: a review

    Get PDF
    Telemedicine applications allow the patient and doctor to communicate with each other through network services. Several medical image compression techniques have been suggested by researchers in the past years. This review paper offers a comparison of the algorithms and the performance by analysing three factors that influence the choice of compression algorithm, which are image quality, compression ratio, and compression speed. The results of previous research have shown that there is a need for effective algorithms for medical imaging without data loss, which is why the lossless compression process is used to compress medical records. Lossless compression, however, has minimal compression ratio efficiency. The way to get the optimum compression ratio is by segmentation of the image into region of interest (ROI) and non-ROI zones, where the power and time needed can be minimised due to the smaller scale. Recently, several researchers have been attempting to create hybrid compression algorithms by integrating different compression techniques to increase the efficiency of compression algorithms

    Hybrid Region-based Image Compression Scheme for Mamograms and Ultrasound Images

    Get PDF
    The need for transmission and archive of mammograms and ultrasound Images has dramatically increased in tele-healthcare applications. Such images require large amount of' storage space which affect transmission speed. Therefore an effective compression scheme is essential. Compression of these images. in general. laces a great challenge to compromise between the higher compression ratio and the relevant diagnostic information. Out of the many studied compression schemes. lossless . IPl. (i- LS and lossy SPII IT are found to he the most efficient ones. JPEG-LS and SI'll IT are chosen based on a comprehensive experimental study carried on a large number of mammograms and ultrasound images of different sizes and texture. The lossless schemes are evaluated based on the compression ratio and compression speed. The distortion in the image quality which is introduced by lossy methods evaluated based on objective criteria using Mean Square Error (MSE) and Peak signal to Noise Ratio (PSNR). It is found that lossless compression can achieve a modest compression ratio 2: 1 - 4: 1. bossy compression schemes can achieve higher compression ratios than lossless ones but at the price of the image quality which may impede diagnostic conclusions. In this work, a new compression approach called Ilvbrid Region-based Image Compression Scheme (IIYRICS) has been proposed for the mammograms and ultrasound images to achieve higher compression ratios without compromising the diagnostic quality. In I LYRICS, a modification for JPI; G-LS is introduced to encode the arbitrary shaped disease affected regions. Then Shape adaptive SPIT IT is applied on the remaining non region of interest. The results clearly show that this hybrid strategy can yield high compression ratios with perfect reconstruction of diagnostic relevant regions, achieving high speed transmission and less storage requirement. For the sample images considered in our experiment, the compression ratio increases approximately ten times. However, this increase depends upon the size of the region of interest chosen. It is also föund that the pre-processing (contrast stretching) of region of interest improves compression ratios on mammograms but not on ultrasound images

    Can high-frequency ultrasound predict metastatic lymph nodes in patients with invasive breast cancer?

    Get PDF
    Aim To determine whether high-frequency ultrasound can predict the presence of metastatic axillary lymph nodes, with a high specificity and positive predictive value, in patients with invasive breast cancer. The clinical aim is to identify patients with axillary disease requiring surgery who would not normally, on clinical grounds, have an axillary dissection, so potentially improving outcome and survival rates. Materials and methods The ipsilateral and contralateral axillae of 42 consecutive patients with invasive breast cancer were scanned prior to treatment using a B-mode frequency of 13 MHz and a Power Doppler frequency of 7 MHz. The presence or absence of an echogenic centre for each lymph node detected was recorded, and measurements were also taken to determine the L/S ratio and the widest and narrowest part of the cortex. Power Doppler was also used to determine vascularity. The contralateral axilla was used as a control for each patient. Results In this study of patients with invasive breast cancer, ipsilateral lymph nodes with a cortical bulge ≥3 mm and/or at least two lymph nodes with absent echogenic centres indicated the presence of metastatic axillary lymph nodes (10 patients). The sensitivity and specificity were 52.6% and 100%, respectively, positive and negative predictive values were 100% and 71.9%, respectively, the P value was 0.001 and the Kappa score was 0.55.\ud Conclusion This would indicate that high-frequency ultrasound can be used to accurately predict metastatic lymph nodes in a proportion of patients with invasive breast cancer, which may alter patient management

    Computer Methods and Programs in Biomedicine XXX (2013) XXX‐XXX 1 Effective Management of Medical Information through ROI-Lossless Fragile Image Watermarking Technique

    Get PDF
    In this article, we have proposed a blind, fragile and Region of Interest (ROI) lossless medical image watermarking (MIW) technique, providing an all-in-one solution tool to various medical data distribution and management issues like security, content authentication, safe archiving, controlled access retrieval and captioning etc. The proposed scheme combines lossless data compression and encryption technique to embed electronic health record (EHR)/DICOM metadata, image hash, indexing keyword, doctor identification code and tamper localization information in the medical images. Extensive experiments (both subjective and objective) were carried out to evaluate performance of the proposed MIW technique. The findings offer suggestive evidence that the proposed MIW scheme is an effective all-in-one solution tool to various issues of medical information management domain. Moreover, given its relative simplicity, the proposed scheme can be applied to the medical images to serve in many medical applications concerned with privacy protection, safety, and management etc. Keywords

    Compressing medical images with minimal information loss

    Get PDF
    This thesis aims to explore the potentialities of neural networks as compression algorithms for medical images. The objective is to develop a compressed image representation suitable for image comparison. In particular we studied different autoencoder architectures, varying the encoding mechanism in order to achieve a high degree of compression while also retaining a meaningful feature space. Our work is focused on mammograms but the methods introduced here can be extrapolated to other types of medical images

    Computer-aided diagnostic systems for digital mammograms

    Get PDF
    A computer-aided diagnostic (CAD) system that uses a unique shape-based classification scheme, the Ellipse-Closed Curve Fitting (ECCF) algorithm, is developed for digital mammogram image analysis. The system is developed to work as a post-processing extension to a previously developed CAD system that locates and segments mass lesions, or tumors, found in digital mammograms into separate images. The ECCF system is implemented in the MATLAB mathematical scripting language and is thus capable of running on multiple platforms. The ECCF algorithm detects edges in tumor images and casts them into closed curve functions. Parameters for an ellipse of best fit for a closed curve function are computed in a way analogous to that in linear regression, where a line of best fit is determined to fit a set of data points. In addition to the shape-fitting algorithm, the ECCF system comprises several other independently functioning components, including auxiliary algorithms and techniques that perform image cropping and edge detection, employed initially to prepare the images for efficient processing, and self-test tools that calculate R2, area matching ratios, and a shape conformity value to determine the goodness of fit . Output generated by the ECCF system for sufficiently large image sets may contain correlations between malignant tumors and their shape that may be captured with data mining techniques, the implementation of which may result in an improved integrated CAD system

    The Comprehensive Review of Neural Network: An Intelligent Medical Image Compression for Data Sharing

    Get PDF
    In the healthcare environment, digital images are the most commonly shared information. It has become a vital resource in health care services that facilitates decision-making and treatment procedures. The medical image requires large volumes of storage and the storage scale continues to grow because of the advancement of medical image technology. To enhance the interaction and coordination between healthcare institutions, the efficient exchange of medical information is necessary. Therefore, the sharing of the medical image with zero loss of information and efficiency needs to be guaranteed exactly. Image compression helps ensure that the purpose of sharing this data from a medical image must be as intelligent as possible to contain valuable information while at the same time minimizing unnecessary diagnostic information. Artificial Neural Network has been used to solve many issues in the processing of images. It has proved its dominance in the handling of noisy or incomplete image compression applications over traditional methods. It contributes to the resulting image by a high compression ratio and noise reduction. This paper reviews previous studies on the compression of intelligent medical images with the neural network approach to data sharing
    corecore