79 research outputs found

    Aircraft electromagnetic compatibility

    Get PDF
    Illustrated are aircraft architecture, electromagnetic interference environments, electromagnetic compatibility protection techniques, program specifications, tasks, and verification and validation procedures. The environment of 400 Hz power, electrical transients, and radio frequency fields are portrayed and related to thresholds of avionics electronics. Five layers of protection for avionics are defined. Recognition is given to some present day electromagnetic compatibility weaknesses and issues which serve to reemphasize the importance of EMC verification of equipment and parts, and their ultimate EMC validation on the aircraft. Proven standards of grounding, bonding, shielding, wiring, and packaging are laid out to help provide a foundation for a comprehensive approach to successful future aircraft design and an understanding of cost effective EMC in an aircraft setting

    Development of the BASS rake acoustic current sensor : measuring velocity in the continental shelf wave bottom boundary layer

    Get PDF
    Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Ocean Engineering, 1997.Includes bibliographical references (p. 343-353).by Arthie Todd Morrison, III.Ph.D

    Refrigerant two-phase flow behaviour and pressure drop up- and downstream of a sharp return bend

    Get PDF
    The European Union’s goals for climate and energy aim for a reduction of Europe's greenhouse gas emissions by 80-95% compared to 1990 levels by the year 2050. One of the technologies that can help to attain such a low-carbon society is a heat pump. It is estimated that the use of heat pumps could reduce the CO2 emissions of the building sector by 50%. An important component of the heat pump system is the heat exchanger, which typically consists of tubes and fins. This type of heat exchanger is also common in other applications such as air-conditioning. For domestic applications it is important that this heat exchanger is constructed in a compact way. To attain a heat exchanger with a limited size, the tubes are folded up into a sequence of short straight channels interconnected by 180° bends. The fluid flowing through these tubes extracts heat from the ambient air and the addition of this heat causes the fluid to evaporate. Research confirms that the presence of the bends do affect the evaporating flow in these channels. However, the underlying mechanisms are still largely unknown. In this work, the effect of the return bend on the flow is investigated and linked to the occurring pressure drop in the channel. The results yield more insight in how the bend geometry affect the flow and what the consequences are for the occurring pressure drop

    Development of a compact wireless SAW Pirani vacuum microsensor with extended range and sensitivity

    Get PDF
    Vakuumsensoren haben nach wie vor einen begrenzten Messbereich und erfordern eine aufwendige Verkabelung sowie eine komplexe Integration in Vakuumkammern. Ein kompakter Sensor, der in der Lage ist, den Erfassungsbereich zwischen Hochvakuum und Atmosphärendruck zu erweitern und dabei drahtlos zu arbeiten, ist äußerst wünschenswert. Der Schwerpunkt dieser Arbeit liegt auf dem Entwurf, der Simulation, der Herstellung und der experimentellen Validierung eines drahtlosen kompakten Vakuum-Mikrosensors mit erweiterter Reichweite und Empfindlichkeit. Zunächst wurde ein neuer Sensor unter Verwendung vorhandener und neu entwickelter Komponenten entworfen. Zweitens wurden die Sensorkomponenten simuliert, um ihre Parameter zu optimieren. Drittens wurde ein Prototyp unter Verwendung der verfügbaren Mikrobearbeitungs- und Halbleitertechnologien hergestellt und montiert. Viertens wurde der Prototyp unter Umgebungs- und Vakuumbedingungen charakterisiert, um seine Leistungen zu validieren. Für das Wandlerprinzip wurden zwei Techniken kombiniert, nämlich Pirani-Sensorik und akustische Oberflächenwellen. Das Design der Sensorkomponenten bestand aus vier Einheiten: Sensoreinheit, Heizeinheit, Abfrageeinheit und Gehäuse. Alle Einheiten wurden in einen kompakten Würfel eingebaut. Einige Komponenten wurden neu entwickelt, während andere gekauft, modifiziert und dann miteinander verbunden wurden. Die Sensoreinheit besteht aus einem neuen Chip mit verbesserter Sensorleistung dank eines optimierten Verhältnisses von Oberfläche zu Volumen. Die Heizeinheit wurde aus zwei induktiv gekoppelten Spulen und der zugehörigen Konditionierungselektronik zusammengesetzt. Die Abfrageeinheit wurde mit einer Mikro-Patch-Antenne hergestellt. Ein würfelförmiges Polymergehäuse wurde entwickelt, um alle Komponenten in einer Vakuumkammer unterzubringen. Zweitens wurde die Simulation des Verhaltens der Sensorkomponenten behandelt. Die für die Druckmessung verantwortliche Wärmeübertragung des Sensorchips wurde vom Hochvakuum bis zum Atmosphärendruck untersucht, um seine Abmessungen zu optimieren. Die Verwendung eines hängenden Lithium-Niobat-Chips mit Y-Z-Schnitt und einem TCF von 94 ppm/K führte zu einer verbesserten Leistung in einem Messbereich zwischen \num{d-4}~Pa und \num{e5}~Pa. Die elektronische Kopplung der Heizspulen wurde ebenfalls simuliert, um die Leistungsübertragung und den Kopplungsabstand zu optimieren. Der dritte Teil betrifft die Herstellungs- und Montageschritte des Prototyps unter Verwendung der verfügbaren Halbleitertechnologien und -ausrüstung. Ein SAW Chip wurde mit einer 100~nm dicken Goldschicht an der Unterseite gesputtert, um den Heizwiderstand zu bilden, und mit Hilfe von Drahtbonding elektrisch mit dem Rest des Sensors verbunden. Es wurde eine Leiterplatte vorbereitet, die die Heiz- und Sensoreinheit enthält. Ein kubisches Gehäusewurde aus PTFE hergestellt. Viertens wurden die Sensorkomponenten zunächst separat charakterisiert, um ihre Leistungen zu überprüfen, und dann zusammen unter Umgebungsbedingungen. Später wurde der Sensor im Vakuum integriert, und es wurde ein druckabhängiges Verhalten des Sensorchips beobachtet. Die Relevanz eines drahtlosen Übertragungsverfahrens wurde den herkömmlichen drahtgebundenen Methoden gegenübergestellt. Die Ergebnisse der experimentellen Arbeiten außerhalb und innerhalb des Vakuums zeigten die Machbarkeit und Relevanz des neuen Konzepts

    Performance improvement of MEMS accelerometers in vibration based diagnosis

    Get PDF
    Vibration measurement and analysis has been an accepted method since decades to meet a number of objectives - machinery condition monitoring, dynamic qualification of any designed structural components, prediction of faults and structural aging-related problems, and several other structural dynamics studies and diagnosis. However, the requirement of the vibration measurement at number of locations in structures, machines and/or equipments makes the vibration measurement exorbitant if conventional piezoelectric accelerometers are used. Hence, there is a need for cheaper and reliable alternative for the conventional accelerometers. The Micro-Electro-Mechanical Systems (MEMS) accelerometers are one such cheap alternative. However, a significant deviation in the performance of the MEMS accelerometers has been observed in earlier research studies and also confirmed by this presented study when compared with well known conventional accelerometer. Therefore, two methods have been suggested to improve the performance of the existing MEMS accelerometers; one for correction in time domain and other in frequency domain. Both methods are based on the generation of a characteristic function (CF) for the MEMS accelerometer using well known reference accelerometer in laboratory tests. The procedures of both methods have been discussed and validations of these methods have been presented through experimental examples. In addition, a Finite Element (FE) model of a typical MEMS accelerometer has been developed and modal analysis has been carried out to understand the dynamics of capacitive type MEMS accelerometer and to identify the source of errors. It has been observed that the moving fingers behave like a cantilever beam while the fixed fingers showed rigid body motion. This cantilever type of motion seems to be causing non-parallel plates effect in the formed capacitors between moving and fixed fingers which results in errors in the vibration measurement. Hence, design modifications on finger shape have been suggested to remove the cantilever motion and results showed remarkable improvement. Moreover, the effect of using synchronous amplitude modulation and demodulation in the readout circuit has been studied. The experimental study showed that this circuit also introduces errors in amplitude and phase of the output signal compared with the input signal. Thus, in the new design of MEMS accelerometers, improvements in both mechanical design and electronic circuit are required.EThOS - Electronic Theses Online ServiceGBUnited Kingdo

    Mechanical systems readiness assessment and performance monitoring study

    Get PDF
    The problem of mechanical devices which lack the real-time readiness assessment and performance monitoring capability required for future space missions is studied. The results of a test program to establish the feasibility of implementing structure borne acoustics, a nondestructive test technique, are described. The program included the monitoring of operational acoustic signatures of five separate mechanical components, each possessing distinct sound characteristics. Acoustic signatures were established for normal operation of each component. Critical failure modes were then inserted into the test components, and faulted acoustic signatures obtained. Predominant features of the sound signature were related back to operational events occurring within the components both for normal and failure mode operations. All of these steps can be automated. The structure borne acoustics technique lends itself to reducing checkout time, simplifying maintenance procedures, and reducing manual involvement in the checkout, operation, maintenance, and fault diagnosis of mechanical systems

    Mars hard lander capsule study. Volume 4 - Capsule point designs and supporting analysis, book 1 Final report

    Get PDF
    Design and performance characteristics of Mars hard lander capsule point designs, and criteria and mission constraints for capsules 1 and

    Development of a 1D phased ultrasonic array for intravascular sonoporation

    Get PDF
    Error on title page – year of award is 2021.Sonoporation represents a promising approach to increase targeted drug delivery efficiency by facilitating transport of therapeutic agents to the target tissue with the use of ultrasound. However, most of the current research in sonoporation is performed with external ultrasonic transducers, which hinders the applicability of the therapeutic procedure for treatment of conditions situated deeper into the patient’s body, such as liver or intestinal tumours. This Thesis presents the development process of a miniature-sized 1-3 connectivity piezocomposite 1D phased array for intracorporeal sonoporation. The device was to be incorporated into a capsule or catheter and hence the primary design constraint was the reduced size of the piezoelectric element, which was limited to 2.5 mm in width and 12 mm in length. To meet the needs of the intended application, resonance frequencies of 1.5 MHz and 3.0 MHz were considered. A simulation framework was developed for optimization of the miniature array in relation to the peak negative pressure attained at the focus to mitigate the low power output associated with the limited device dimensions. This was implemented through a multiparametric sweep of the 1-3 piezocomposite geometry-related parameters. Devices made with PZT-5H and PMN-29%PT were evaluated. The optimization algorithm was used to determine specifications for phased array designs based on the two materials and the two resonance frequencies. The 1.5 MHz devices comprised 24 elements and the 3.0 MHz ones had 32 elements. The piezocomposites were manufactured using the dice and fill technique and electroded using a novel method of electrode deposition employing spin coating of Ag ink. Subsequently, the prototype devices were driven with a commercial array controller and characterized with a calibrated needle hydrophone in a scanning tank. Two simulation profiles based on finite element analysis and time extrapolation were developed to model the acoustic beams from the arrays, which were compared and calibrated with experimental data for focal distances between 5 mm and 10 mm and beam steering angles from 0° to 40°. The results showed that modelling could be employed reliably for therapeutic planning. Both the 1.5 MHz and the 3.0 MHz, PZT-5H arrays were tested in vitro and shown to induce and control sonoporation of a human epithelial colorectal adenocarcinoma cell layer. Finally, a 24 element, 1.5 MHz, PZT-5H array was implemented in a 40 mm long by 11 mm diameter tethered, biocompatible capsule intended for in vivo operation. The device was characterized in the scanning tank for steering angles in the range 0° to 56° and focal distances between 4.0 mm and 5.7 mm, and the measured beam profiles were correlated with the simulation framework. The capsule will be tested in future ex-vivo and in-vivo experiments on insulin absorption through porcine small bowel by means of sonoporation.Sonoporation represents a promising approach to increase targeted drug delivery efficiency by facilitating transport of therapeutic agents to the target tissue with the use of ultrasound. However, most of the current research in sonoporation is performed with external ultrasonic transducers, which hinders the applicability of the therapeutic procedure for treatment of conditions situated deeper into the patient’s body, such as liver or intestinal tumours. This Thesis presents the development process of a miniature-sized 1-3 connectivity piezocomposite 1D phased array for intracorporeal sonoporation. The device was to be incorporated into a capsule or catheter and hence the primary design constraint was the reduced size of the piezoelectric element, which was limited to 2.5 mm in width and 12 mm in length. To meet the needs of the intended application, resonance frequencies of 1.5 MHz and 3.0 MHz were considered. A simulation framework was developed for optimization of the miniature array in relation to the peak negative pressure attained at the focus to mitigate the low power output associated with the limited device dimensions. This was implemented through a multiparametric sweep of the 1-3 piezocomposite geometry-related parameters. Devices made with PZT-5H and PMN-29%PT were evaluated. The optimization algorithm was used to determine specifications for phased array designs based on the two materials and the two resonance frequencies. The 1.5 MHz devices comprised 24 elements and the 3.0 MHz ones had 32 elements. The piezocomposites were manufactured using the dice and fill technique and electroded using a novel method of electrode deposition employing spin coating of Ag ink. Subsequently, the prototype devices were driven with a commercial array controller and characterized with a calibrated needle hydrophone in a scanning tank. Two simulation profiles based on finite element analysis and time extrapolation were developed to model the acoustic beams from the arrays, which were compared and calibrated with experimental data for focal distances between 5 mm and 10 mm and beam steering angles from 0° to 40°. The results showed that modelling could be employed reliably for therapeutic planning. Both the 1.5 MHz and the 3.0 MHz, PZT-5H arrays were tested in vitro and shown to induce and control sonoporation of a human epithelial colorectal adenocarcinoma cell layer. Finally, a 24 element, 1.5 MHz, PZT-5H array was implemented in a 40 mm long by 11 mm diameter tethered, biocompatible capsule intended for in vivo operation. The device was characterized in the scanning tank for steering angles in the range 0° to 56° and focal distances between 4.0 mm and 5.7 mm, and the measured beam profiles were correlated with the simulation framework. The capsule will be tested in future ex-vivo and in-vivo experiments on insulin absorption through porcine small bowel by means of sonoporation
    • …
    corecore