87 research outputs found

    Challenges of continuum robots in clinical context: a review

    Get PDF
    With the maturity of surgical robotic systems based on traditional rigid-link principles, the rate of progress slowed as limits of size and controllable degrees of freedom were reached. Continuum robots came with the potential to deliver a step change in the next generation of medical devices, by providing better access, safer interactions and making new procedures possible. Over the last few years, several continuum robotic systems have been launched commercially and have been increasingly adopted in hospitals. Despite the clear progress achieved, continuum robots still suffer from design complexity hindering their dexterity and scalability. Recent advances in actuation methods have looked to address this issue, offering alternatives to commonly employed approaches. Additionally, continuum structures introduce significant complexity in modelling, sensing, control and fabrication; topics which are of particular focus in the robotics community. It is, therefore, the aim of the presented work to highlight the pertinent areas of active research and to discuss the challenges to be addressed before the potential of continuum robots as medical devices may be fully realised

    Modeling, Analysis, Force Sensing and Control of Continuum Robots for Minimally Invasive Surgery

    Get PDF
    This dissertation describes design, modeling and application of continuum robotics for surgical applications, specifically parallel continuum robots (PCRs) and concentric tube manipulators (CTMs). The introduction of robotics into surgical applications has allowed for a greater degree of precision, less invasive access to more remote surgical sites, and user-intuitive interfaces with enhanced vision systems. The most recent developments have been in the space of continuum robots, whose exible structure create an inherent safety factor when in contact with fragile tissues. The design challenges that exist involve balancing size and strength of the manipulators, controlling the manipulators over long transmission pathways, and incorporating force sensing and feedback from the manipulators to the user. Contributions presented in this work include: (1) prototyping, design, force sensing, and force control investigations of PCRs, and (2) prototyping of a concentric tube manipulator for use in a standard colonoscope. A general kinetostatic model is presented for PCRs along with identification of multiple physical constraints encountered in design and construction. Design considerations and manipulator capabilities are examined in the form of matrix metrics and ellipsoid representations. Finally, force sensing and control are explored and experimental results are provided showing the accuracy of force estimates based on actuation force measurements and control capabilities. An overview of the design requirements, manipulator construction, analysis and experimental results are provided for a CTM used as a tool manipulator in a traditional colonoscope. Currently, tools used in colonoscopic procedures are straight and exit the front of the scope with 1 DOF of operation (jaws of a grasper, tightening of a loop, etc.). This research shows that with a CTM deployed, the dexterity of these tools can be increased dramatically, increasing accuracy of tool operation, ease of use and safety of the overall procedure. The prototype investigated in this work allows for multiple tools to be used during a single procedure. Experimental results show the feasibility and advantages of the newly-designed manipulators

    下腹部を対象とした極細針によるCTガイド下高正確度穿刺プランニング

    Get PDF
    早大学位記番号:新8149早稲田大

    Characterisation and State Estimation of Magnetic Soft Continuum Robots

    Get PDF
    Minimally invasive surgery has become more popular as it leads to less bleeding, scarring, pain, and shorter recovery time. However, this has come with counter-intuitive devices and steep surgeon learning curves. Magnetically actuated Soft Continuum Robots (SCR) have the potential to replace these devices, providing high dexterity together with the ability to conform to complex environments and safe human interactions without the cognitive burden for the clinician. Despite considerable progress in the past decade in their development, several challenges still plague SCR hindering their full realisation. This thesis aims at improving magnetically actuated SCR by addressing some of these challenges, such as material characterisation and modelling, and sensing feedback and localisation. Material characterisation for SCR is essential for understanding their behaviour and designing effective modelling and simulation strategies. In this work, the material properties of commonly employed materials in magnetically actuated SCR, such as elastic modulus, hyper-elastic model parameters, and magnetic moment were determined. Additionally, the effect these parameters have on modelling and simulating these devices was investigated. Due to the nature of magnetic actuation, localisation is of utmost importance to ensure accurate control and delivery of functionality. As such, two localisation strategies for magnetically actuated SCR were developed, one capable of estimating the full 6 degrees of freedom (DOFs) pose without any prior pose information, and another capable of accurately tracking the full 6-DOFs in real-time with positional errors lower than 4~mm. These will contribute to the development of autonomous navigation and closed-loop control of magnetically actuated SCR

    Robotic manipulators for in situ inspections of jet engines

    Get PDF
    Jet engines need to be inspected periodically and, in some instances, repaired. Currently, some of these maintenance operations require the engine to be removed from the wing and dismantled, which has a significant associated cost. The capability of performing some of these inspections and repairs while the engine is on-wing could lead to important cost savings. However, existing technology for on-wing operations is limited, and does not suffice to satisfy some of the needs. In this work, the problem of performing on-wing operations such as inspection and repair is analysed, and after an extensive literature review, a novel robotic system for the on-wing insertion and deployment of probes or other tools is proposed. The system consists of a fine-positioner, which is a miniature and dexterous robotic manipulator; a gross-positioner, which is a device to insert the fine-positioner to the engine region of interest; an end-effector, such as a probe; a deployment mechanism, which is a passive device to ensure correct contact between probe and component; and a feedback system that provides information about the robot state for control. The research and development work conducted to address the main challenges to create this robotic system is presented in this thesis. The work is focussed on the fine-positioner, as it is the most relevant and complex part of the system. After a literature review of relevant work, and as part of the exploration of potential robot concepts for the system, the kinematic capabilities of concentric tube robots (CTRs) are first investigated. The complete set of stable trajectories that can be traced in follow-the-leader motion is discovered. A case study involving simulations and an experiment is then presented to showcase and verify the work. The research findings indicate that CTRs are not suitable for the fine-positioner. However, they show that CTRs with non-annular cross section can be used for the gross-positioner. In addition, the new trajectories discovered show promise in minimally invasive surgery (MIS). Soft robotic manipulators with fluidic actuation are then selected as the most suitable concept for the fine-positioner. The design of soft robotic manipulators with fluidic actuation is investigated from a general perspective. A general framework for the design of these devices is proposed, and a set of design principles are derived. These principles are first applied in a MIS case study to illustrate and verify the work. Finite element (FE) simulations are then reported to perform design optimisation, and thus complete the case study. The design study is then applied to determine the most suitable design for the fine-positioner. An additional analytical derivation is developed, followed by FE simulations, which extend those of the case study. Eventually, this work yields a final design of the fine-positioner. The final design found is different from existing ones, and is shown to provide an important performance improvement with respect to existing soft robots in terms of wrenches it can support. The control of soft and continuum robots relevant to the fine-positioner is also studied. The full kinematics of continuum robots with constant curvature bending and extending capabilities are first investigated, which correspond to a preliminary design concept conceived for the fine-positioner. Closed-form solutions are derived, closing an open problem. These kinematics, however, do not exactly match the final fine-positioner design selected. Thus, an alternative control approach based on closed-loop control laws is then adopted. For this, a mechanical model is first developed. Closed-loop control laws are then derived based on this mechanical model for planar operation of a segment of the fine-positioner. The control laws obtained represent the foundation for the subsequent development of control laws for a full fine-positioner operating in 3D. Furthermore, work on path planning for nonholonomic systems is also reported, and a new algorithm is presented, which can be applied for the insertion of the overall robotic system. Solutions to the other parts of the robotic system for on-wing operations are also reported. A gross-positioner consisting of a non-annular CTR is proposed. Solutions for a deployment mechanism are also presented. Potential feedback systems are outlined. In addition, methods for the fabrication of the systems are reported, and the electronics and systems required for the assembly of the different parts are described. Finally, the use of the robotic system to perform on-wing inspections in a representative case study is studied to determine the viability. Inspection strategies are shortlisted, and simulations and experiments are used to study them. The results, however, indicate that inspection is not viable since the signal to noise ratio is excessively low. Nonetheless, the robotic system proposed, and the research conducted, are still expected to be useful to perform a range of on-wing operations that require the insertion and deployment of a probe or other end-effector. In addition, the trajectories discovered for CTRs, the design found for the fine-positioner, and the advances on control, also have significant potential in MIS, where there is an important need for miniature robotic manipulators and similar devices.Open Acces

    Low Velocity Impact Behavior and Modeling of Loose-Knit Polymer Composite Materials

    Get PDF
    An investigation into knitted reinforced polymer composites was performed with emphasis on the impact behavior associated with this material type. Overviews of knitting terminology and some applications available for knitted reinforced polymer composites are presented. Impact performance characteristics are examined with emphasis on testing and evaluation techniques available. Large deformation behavior was observed in testing and modeling areas with elastomeric polymer materials being the main subject of discussion. This allowed the knitted fabric reinforcement to be taken advantage of in these flexible composites. An impact test rig was created in order to analyze the performance of two different types of knitted reinforced polymer composite material, with emphasis on a commercially available product due to its availability. The test setup will be discussed in great detail and will be based on designs found in the literature. Post impact analysis will be performed based on techniques outlined in the literature with examination of the permanent deformation and energy absorbing capabilities of the materials tested.Through an industrial partnership program, a large scale finite element model was created in order to examine the wind uplift performance of a commercial roofing application. This model will be created in a multi-level fashion from micro-scale to macro-scale in order to examine the effects each of the constituents has on the overall performance of the composite membrane. Material property testing and curve fit capabilities will be employed in order to create the material models used in the finite element simulations. Comparisons between experimental tests and simulation results will show good agreement between the two, allowing for validation in potential usage of the model for predictive based purposes in order to provide recommendations for best changes to the material to explore further

    Force Sensing Surgical Scissor Blades using Fibre Bragg Grating Sensors

    Get PDF
    This thesis considers the development and analysis of unique sensorised surgical scissor blades for application in minimally invasive robotic surgery (MIRS). The lack of haptic (force and tactile) feedback to the user is currently an unresolved issue with modern MIRS systems. This thesis presents details on smart sensing scissor blades which enable the measurement of instrument-tissue interaction forces for the purpose of force reflection and tissue property identification. A review of current literature established that there exists a need for small compact, biocompatible, sterilisable and robust sensors which meet the demands of current MIRS instruments. Therefore, the sensorised blades exploit the strain sensing capabilities of a single fibre Bragg grating (FBG) sensor bonded to their surface. The nature and magnitude of the strain likely to be experienced by the blades, and consequently the FBG sensor, while cutting soft tissue samples were characterised through the use of an application specific test-bed. Using the sensorised blades to estimate fracture properties is proposed, hence two methods of extracting fracture toughness information from the test samples are assessed and compared. Investigations were carried out on the factors affecting the transfer of strain from the blade material to the core of the FBG sensor for surface mounted or partially embedded arrangements. Results show that adhesive bond length, thickness and stiffness need to be carefully specified when bonding FBG sensors to ensure effective strain transfer. Calibration and dynamic cutting experiments were carried out using the characterisation test-bed. The complex nature of the blade interaction forces were modelled, primarily for the purpose of decoupling the direct, lateral, friction and fracture strains experienced by the bonded FBG sensor during cutting. The modelled and experimental results show that the approach taken in sensorising the blade enables detailed cutting force data to be obtained and consequently leads to a unique method in estimating the kinetic friction coefficient for the blades. The forces measured using the FBG are validated against a commercial load cell used in the test-bed. This research work demonstrates that this unique approach of placing a single optical fibre onto the scissor blades can, in an unobtrusive manner, measure interblade friction forces and material fracture properties occurring at the blade-tissue interface

    Data-driven modelling and control of concentric tube robots with application in distal lung sampling

    Get PDF
    This research aims to explore the use of Concentric Tube Robots (CTRs) as a novel alternative to needle-based interventions in order to make these procedures more accurate and repeatable. CTRs due to their small footprint, compliance, and dexterity have been proposed for several minimally-invasive robotic surgeries. As a novel flexible robot, it has the potential to reach distal parts of the human lung that are difficult or impossible to reach with conventional needle-based interventions. There are, however, still significant challenges associated with the motion and position control of CTRs. Commonly used model-based control approaches are computationally expensive to solve and often employ simplified geometric/dynamic assumptions, which could be inaccurate in the presence of unmodelled disturbances and external interaction forces. Consequently, this work explores different control strategies to overcome these limitation. This is achieved by first building a simulation environment based on a computationally improved kinematic model that enables real-time control. Then, data-driven control approaches are investigated in order to provide accurate position control in the presence of uncertainties in the system. Finally, a three-phase affordance-aware motion planner is proposed to demonstrate the feasibility of using CTRs for percutaneous lung biopsy. According to this, the first part of this work concentrates on computationally efficient real-time modelling and simulation of CTRs. In order to achieve this, two approaches are taken. The first one introduces a method that can rapidly estimate the solution of the kinematic model, while the second approach focuses on implementing the existing model in a computationally efficient way in Robot Operating System (ROS) using C++. Second, this work explores data-driven solutions to control the robot without relying on the kinematic model. Consequently, two data-driven solutions are proposed, namely the Hybrid Dual Jacobian approach and the Extended Dynamic Mode Decomposition (EDMD) algorithm. The hybrid controller combines the advantages of model-based and data-driven control approaches, while the EDMD provides a completely model-free solution to control the robot. Both controllers are capable of rapidly predicting the robot’s nonlinear dynamics from a limited data set and offer consistent control under external loading and in the presence of obstacles. The third part of the thesis explores the use of CTRs in the context of distal lung sampling. This work demonstrates that CTRs are suitable for Needle-Based Optical Endomicroscopy where a CTR steers a fluorescent imaging probe with cellular and bacterial imaging capability inside soft tissue. Then, it is also demonstrated that a CTR can be used as a Steerable Needle to reach a target deep inside the tissue. To achieve these tasks, a motion planner is essential due to the fact that a CTR is only capable of reaching specific points in its workspace and there are a number of configurations where the robot becomes unstable. Based on this, a threeii phase affordance-aware motion planner algorithm is developed. The motion planner selects the best entry point for a specific task. Based on the selected entry point it first generates a stable trajectory from the robot’s initial configuration to the selected entry point. Then, a feasible trajectory is generated from the entry point to the target. Finally, the proposed datadriven control algorithm is applied to autonomously steer the robot on the generated trajectory toward the target region for endomicroscopic imaging
    corecore