167 research outputs found

    3D Additive Manufacturing Symposium & Workshop

    Get PDF
    The IMI /3M BIC 3D Additive Manufacturing Symposium and Workshop was hosted by 3M Buckley Innovation Centre on March 17th 2015. The event was attended by the major players in precision engineering, 3D additive design and manufacturing: Representatives from EOS, Renishaw, HK 3D Printing IMI Plc Senior Management team, design engineers, programmers and academics from the University of Huddersfield School of Art Design & Architecture, 3M Buckley centre 3D printing management and designers shared their experiences and latest solutions to expand the potential of innovation and professional enterprise for design, prototyping and manufacturing. This publication showcases the keynote innovation presentations given at the IMI/3M BIC 3D Additive Manufacturing symposium. The main themes included focus on research, design, concept actualisation, prototyping, and engineering solutions. This is a unique visual documentary of the evolutions in additive manufacturing and provides a snaphsot of latest 3D technology solutions in 2015

    Effect of the interface geometry on the structural integrity of the ceramic crown-tooth complex

    Get PDF
    The effect of the interface lute on the structural integrity of the tooth adhesively restored with an all-ceramic crown remains is an unknown parameter especially in relation to the interface geometry (thickness and uniformity). Traditionally, the structural integrity of a restored tooth system (tooth-lute-crown) is tested by laboratory based mechanical testing. However, a more sophisticated FEA computer modelling seems to provide a non-destructive way of understanding the structural integrity of the system, which may complement mechanical testing

    Digital Workflows and Material Sciences in Dental Medicine

    Get PDF
    The trend of digitalization is an omnipresent phenomenon nowadays – in social life and in the dental community. Advancement in digital technology has fostered research into new dental materials for the use of these workflows, particularly in the field of prosthodontics and oral implantology.CAD/CAM-technology has been the game changer for the production of tooth-borne and implant-supported (monolithic) reconstructions: from optical scanning, to on-screen designing, and rapid prototyping using milling or 3D-printing. In this context, the continuous development and speedy progress in digital workflows and dental materials ensure new opportunities in dentistry.The objective of this Special Issue is to provide an update on the current knowledge with state-of-the-art theory and practical information on digital workflows to determine the uptake of technological innovations in dental materials science. In addition, emphasis is placed on identifying future research needs to manage the continuous increase in digitalization in combination with dental materials and to accomplish their clinical translation.This Special Issue welcomes all types of studies and reviews considering the perspectives of the various stakeholders with regard to digital dentistry and dental materials

    The influence of different surface and heat treatments on the biaxial flexural strength of veneering ceramics for zirconia and strength reliability and mode of fracture of veneering ceramics

    Get PDF
    Tese de doutoramento, Medicina DentĂĄria (Reabilitação Oral), Universidade de Lisboa, Faculdade de Medicina DentĂĄria, 2011New processing techniques have facilitated the use of Zirconia core materials in all-ceramic dental prostheses. Zirconia has many potential advantages compared to existing core materials; however its performance when layered with veneering ceramics has not been clearly evaluated. Moreover the veneering ceramics used with Zirconia may be ground, polished or glazed during laboratory procedures and/or clinical adjustments. These treatments may affect their strength by introducing microscopic flaws and defects. The purposes of this study were to investigate the effects of surface treatments on the mean biaxial flexural strength of three feldspathic veneering ceramics used to layer Zirconia cores: NobelRondoTM Zirconia veneer ceramic (Nobel BiocareTM AB, Sweden), LavaTM Ceram veneer ceramic (3MTM, ESPETM, Germany), and VitaÂź VMÂź9 veneer ceramic (VitaÂź, Zahnfabrick, Germany) and compare the mean biaxial flexural strength, its reliability, and mode of fracture of bilayered Zirconia discs veneered with the three feldspathic veneering ceramics. For the first part of the study one hundred and eighty monolithic disc specimens (12.7 mm x 2.2mm), sixty for each feldspathic veneering ceramic were prepared according to the manufacturer’s instruction and divided into eighteen groups, 6 groups for each feldspathic veneering ceramic with 10 specimens for each group. The six groups for each feldspathic veneering ceramic were untreated, grounded, grounded and polished, grounded and glazed, grounded polished and glazed and polished and glazed. Mean biaxial flexural strength and Weibull modulus were appraised. Statistical significance Summary 236 among groups of population was analyzed using one-way and two-way ANOVA and Fisher's PLSD comparison tests. For the second part of the study sixty bilayered disc specimens (12.7 mm x 2.2 mm), twenty for each feldspathic veneering ceramic were prepared using sixty Zirconia core discs (12.7 mm x 1.1 mm) layered with the three feldspathic veneering ceramics according to the manufacturer’s instruction and divided into 6 groups of 10 specimens for each material. Mean biaxial flexural strength and Weibull modulus were appraised, and a scanning electron microscope was used to describe surface features. Statistical significance among groups of population was analyzed using two-way ANOVA, Fisher's PLSD and Student’s t-test comparison tests. For the first part of the study and when the veneering ceramics were analyzed together the data provided strong evidence that there was a significant difference in biaxial flexural strength between the grinding groups and all other groups. When the feldspathic veneering ceramics were analyzed individually data revealed more heterogeneity between the mean biaxial strength of different groups. However, grinding decrease the strength of veneering ceramics and in some cases significantly. For this reason, grinding should always be avoided if any other procedure is to be done, as this will either create or change the developed crack dimensions or increase the volume loss. Conversely polishing and glazing improved the strength of all materials and in same cases significantly. These procedures are recommended to counteract the detrimental effects of grinding which was related to the ability of the procedures to improve the condition of the ceramic’s surface and free it from various defects and flaws. The Weibull modulus values for the veneering ceramics tested varied with different treatments. They showed higher values for polished, glazed and untreated groups, and lower values for ground groups. For the bilayered specimens when the veneering ceramics were Summary 237 analyzed together, specimens with the core material on the bottom surface were statistically stronger and more reliable than those with the veneering ceramics on the bottom surface. When analyzed individually only in the NobelRondoTM Zirconia veneer ceramic there was no significant difference when the core material or the veneering ceramic was on the bottom surface. Two different modes of fracture were observed in the bilayered specimens according to which material was on the bottom surface. The material that underwent tensile stress dictated the strength, reliability, and fracture mode of the specimens. The design of the restorations and the actual distribution of the tensile stresses must be taken into account, otherwise the significant contribution of stronger and tougher core materials to the performance of all-ceramic Zirconia-based restorations may be offset by the weaker veneering ceramics.Com o objectivo de ultrapassar as limitaçÔes dos materiais em cerĂąmica pura tradicionais, diversas companhias introduziram em medicina dentĂĄria reabilitadora um material de elevada resistĂȘncia composto por cerĂąmica de ZircĂłnia. A sua aplicação em prostodontia estĂĄ a emergir devido fundamentalmente Ă s suas excelentes propriedades mecĂąnicas, biolĂłgicas e estĂ©ticas e ao desenvolvimento de novas tecnologias, como a tecnologia CAD/CAM, que permitem a confecção de coroas unitĂĄrias e prĂłteses parciais fixas de uma forma standardizada e eficiente. Apesar das enormes e aparentes vantagens da ZircĂłnia, comparativamente aos materiais cerĂąmicos tradicionais utilizados como infraestrutura de restauraçÔes protĂ©ticas, o seu desempenho clĂ­nico quando estratificada com cerĂąmicas feldspĂĄticas de revestimento nĂŁo tem sido atĂ© agora avaliada com evidĂȘncia. Do ponto de vista da selecção de material, a substituição de materiais cerĂąmicos tradicionais ou mesmo alumina por ZircĂłnia com maior resistĂȘncia deveria melhorar a performance clĂ­nica das coroas tendo como referĂȘncia a origem da fractura. No entanto, a resistĂȘncia das cerĂąmicas feldspĂĄticas, e consequentemente de uma restauração em cerĂąmica pura com nĂșcleo de ZircĂłnia, estĂĄ dependente do grau de polimento final da restauração e dos diferentes procedimentos de fabricação no laboratĂłrio e ou ajustes clĂ­nicos que possibilitem uma correcta adaptação e ou oclusĂŁo. Os procedimentos de processamento e ou ajustes clĂ­nicos sĂŁo passĂ­veis de provocar pequenos defeitos microcĂłpicos e ou fissuras sub-crĂ­ticas, que poderĂŁo ser Resumo 240 acompanhados por uma alteração e consequente redução de resistĂȘncia Ă  fractura. A presença destas fissuras pode como consequĂȘncia de carga clĂ­nica e ou presença de humidade crescer para uma situação crĂ­tica limite levando a falha catastrĂłfica. O efeito dos procedimentos de processamento de materiais cerĂąmicos tem sido estudado por numerosos investigadores. No entanto, existe ainda controvĂ©rsia no que respeita ao melhor mĂ©todo para produzir a superfĂ­cie mais polida e resistente. No sentido de avaliar todas estas suposiçÔes os objectivos deste estudo foram avaliar a resistĂȘncia Ă  fractura medida atravĂ©s da resistĂȘncia Ă  flexĂŁo biaxial de cerĂąmicas feldspĂĄticas de revestimento de ZircĂłnia quando submetidas a tratamentos de superfĂ­cie nomeadamente, desgaste, polimento e tratamento tĂ©rmico; e avaliar a resistĂȘncia, a fiabilidade e o modo de fractura de restauraçÔes em cerĂąmica pura com infra-estrutura de ZircĂłnia estratificadas com diferentes cerĂąmicas de revestimento. Para alcançar estes objectivos, foram efectuadas avaliaçÔes quantitativas da resistĂȘncia Ă  flexĂŁo biaxial, avaliaçÔes qualitativas da ultramorfologia e modo de fractura da interface cerĂąmica de revestimento – infraestrutura de ZircĂłnia. A estratĂ©gia seguida levou Ă  formulação das seguintes hipĂłteses experimentais: H1.0: NĂŁo existem diferenças significativas na resistĂȘncia Ă  fractura, medida em termos de resistĂȘncia Ă  flexĂŁo biaxial, entre os diferentes tratamentos de superfĂ­cie no conjunto das cerĂąmicas feldspĂĄticas de revestimento. H1.1: Existem diferenças significativas na resistĂȘncia Ă  fractura, medida em termos de resistĂȘncia Ă  flexĂŁo biaxial, entre os diferentes tratamentos de superfĂ­cie no conjunto das cerĂąmicas feldspĂĄticas de revestimento. Resumo 241 H2.0: NĂŁo existem diferenças significativas na resistĂȘncia Ă  fractura, medida em termos de resistĂȘncia Ă  flexĂŁo biaxial, entre os diferentes tratamentos de superfĂ­cie em cada uma das cerĂąmicas feldspĂĄticas de revestimento. H2.1: Existem diferenças significativas na resistĂȘncia Ă  fractura, medida em termos de resistĂȘncia Ă  flexĂŁo biaxial, entre os diferentes tratamentos de superfĂ­cie em cada uma das cerĂąmicas feldspĂĄticas de revestimento. H3.0: NĂŁo existem diferenças significativas na resistĂȘncia Ă  fractura, medida em termos de resistĂȘncia Ă  flexĂŁo biaxial, no conjunto das cerĂąmicas feldspĂĄticas de revestimento/infra-estruturas de ZircĂłnia independentemente do material submetido a stress tensional. H3.1: Existem diferenças significativas na resistĂȘncia Ă  fractura, medida em termos de resistĂȘncia Ă  flexĂŁo biaxial, no conjunto das cerĂąmicas feldspĂĄticas de revestimento/infra-estruturas de ZircĂłnia independentemente do material submetido a stress tensional. H4.0: NĂŁo existem diferenças significativas na resistĂȘncia Ă  fractura, medida em termos de resistĂȘncia Ă  flexĂŁo biaxial, em cada uma das cerĂąmicas feldspĂĄticas de revestimento/infra-estruturas de ZircĂłnia independentemente do material submetido a stress tensional. H4.1: Existem diferenças significativas na resistĂȘncia Ă  fractura, medida em termos de resistĂȘncia Ă  flexĂŁo biaxial, em cada uma das cerĂąmicas feldspĂĄticas de revestimento/infra-estruturas de ZircĂłnia independentemente do material submetido a stress tensional. H5.0: NĂŁo existem diferenças significativas no modo de fractura das cerĂąmicas feldspĂĄticas de revestimento/infra-estruturas de ZircĂłnia Resumo 242 independentemente do material submetido a stress tensional. H5.1: Existem diferenças significativas no modo de fractura das cerĂąmicas feldspĂĄticas de revestimento/infra-estruturas de ZircĂłnia independentemente do material submetido a stress tensional. Na primeira parte da investigação uma amostra de conveniĂȘncia de cento e oitenta (180) espĂ©cimes em forma de disco (12.7 mm x 2.2 mm) foram preparados e usados neste estudo. Os discos foram fabricados com cerĂąmica feldspĂĄtica utilizada para estratificar infra-estruturas de ZircĂłnia 3YTZP de trĂȘs (3) marcas comerciais: NobelRondoTM Zirconia veneer ceramic (Nobel BiocareTM AB, SuĂ©cia), LavaTM Ceram veneer ceramic (3MTM, ESPETM, Alemanha), e VitaÂź VMÂź9 veneer ceramic (VitaÂź, Zahnfabrick, Alemanha). Sessenta (60) espĂ©cimes monolĂ­ticos de cada cerĂąmica foram fabricadas de acordo com as instruçÔes ISO/DIS 6872: 1995 (three-point and biaxial flexural strength) usando um molde de aço inoxidĂĄvel (ISO/DIS 6872: 1995). O lĂ­quido de mistura e o pĂł cerĂąmico foram combinados nas proporçÔes recomendadas pelo fabricante. A mistura resultante de cerĂąmica feldspĂĄtica foi vibrada e compactada no molde e posteriormente sinterizada em forno especĂ­fico para cerĂąmica (Programat P500, Ivoclar Vivadent AG, Liechtenstein). ApĂłs a primeira sinterização mais cerĂąmica foi adicionada por forma a compensar a contracção resultante da primeira sinterização. Os discos de cerĂąmica produzidos foram examinados com um estereomicroscĂłpio (Nikon SMZ-U, Tokyo, Japan) com uma ampliação X75 para avaliar a presença de pequenas fissuras ou poros. EspĂ©cimes que demonstrassem defeitos visĂ­veis foram substituĂ­dos. A superficie de todas os espĂ©cimes foi posteriormente polida com discos de carbureto de silĂ­cio (grĂŁo P220, P500, P1200 - Ultra-Prep, Buehler Ltd., Lake Bluff, IL, EUA) numa lixadora mecĂąnica (EcometÂź 3, Buehler Ltd., Lake Buff, IL, EUA) de acordo Resumo 243 com ISO 6344-1: 1998 (ISO/DIS 6344-1: 1998). Este procedimento foi efectuado atĂ© serem obtidos espĂ©cimes com 2.2(± 0.1) mm por 12.7(± 0.1) mm de espessura e diĂąmetro respectivamente. Um transportador especial de aço inoxidĂĄvel foi utilizado para assegurar a uniformização da espessura e paralelismo das superficies durante o corte e polimento. As dimensĂ”es dos espĂ©cimes foram avaliadas atravĂ©s da utilização de um medidor digital (Digimatic Caliper Series 500, Mitutoyo America Corporation, Aurora, IL, EUA) por forma a garantir espessura e diĂąmetros exactos. Finalmente, todas os espĂ©cimes foram limpas com ĂĄgua destilada num banho de ultra-sons (EurosonicÂź 4D, Euronda, Vicenza, Italia) durante 15 minutos e posteriormente colocados no forno especĂ­fico para cerĂąmica onde foram auto-glazeados. ApĂłs o glaze, a espessura final e o diĂąmetro foram novamente avaliados atravĂ©s da utilização do mesmo medidor digital atĂ© ao centĂ©simo de milimetro. Os cento e oitenta (180) espĂ©cimes foram aleatoriamente distribuidos por dezoito grupos, seis grupos para cada cerĂąmica, cada grupo composto por dez espĂ©cimes. Os seis grupos experimentais de cada cerĂąmica foram fabricados como anteriormente descrito e submetidos aos seguintes tratamentos de superfĂ­cie: 1) preparação segundo as instruçÔes do fabricante (grupo de controlo) (C), 2) com desgaste/corte da superfĂ­cie com instrumento de diamante (G), 3) com desgaste/corte da superfĂ­cie com instrumento de diamante seguido de glaze (GG), 4) com desgaste/corte da superfĂ­cie com instrumento de diamante seguido de polimento (GP), 5) com desgaste/corte da superfĂ­cie com instrumento de diamante seguido de polimento e glaze (GPG), 6) Com polimento da superfĂ­cie seguido de glaze (PG). A resistĂȘncia mĂĄxima Ă  fractura foi medida atravĂ©s do mĂ©todo “pistonon- three-ball” utilizando uma mĂĄquina de testes mecĂąnicos universal Instron (Modelo TT-BM Instron Corp., Canton, MA), e de acordo com o standard ISO/DIS 6872 para cerĂąmicas dentĂĄrias (ISO/DIS 6872: 1995). A resistĂȘncia Resumo 244 mĂĄxima Ă  fractura (N) foi registada e conjugada com a seguinte formula (ASTM F 394-78, 1996), por forma a obter e calcular a resistĂȘncia Ă  flexĂŁo biaxial para cada espĂ©cime: S = - 0.2387 P(X – Y)/d2 (ISO/DIS 6872: 1995). Conjuntamente foi calculado o Weibull modulus para a resistĂȘncia Ă  flexĂŁo biaxial obtida. A anĂĄlise estatĂ­stica dos resultados foi efectuada atravĂ©s da utilização do mĂ©todo one-way and two-way ANOVA com ajustamento de Fisher's PLSD post-hoc para comparaçÔes mĂșltiplas (p=0.05), para avaliar as diferenças de resistĂȘncia Ă  fractura entre grupos. Na segunda parte da investigação uma amostra de coveniĂȘncia de sessenta (60) espĂ©cimes em forma de disco (12.7 mm x 2.2 mm) foram preparados e usados neste estudo. Os discos foram fabricados utilizando sessenta discos de ZircĂłnia 3Y-TZP produzidos por CAD/CAM (Nobel BiocareTM AB, SuĂ©cia) (12.7 mm x 1.1 mm) que foram revestidos com cerĂąmica feldspĂĄtica utilizada para estratificar infra-estruturas de ZircĂłnia 3YTZP de trĂȘs (3) marcas comerciais: NobelRondoTM Zirconia veneer ceramic (Nobel BiocareTM AB, SuĂ©cia), LavaTM Ceram veneer ceramic (3MTM, ESPETM, Alemanha), e VitaÂź VMÂź9 veneer ceramic (VitaÂź, Zahnfabrick, Alemanha). A preparação dos sessenta (60) espĂ©cimes, vinte (20) de cada cerĂąmica foi efectuada de acordo com as instruçÔes ISO/DIS 6872: 1995 (three-point and biaxial flexural strength) (ISO/DIS 6872: 1995) usando as recomendaçÔes especĂ­ficas de cada fabricante e de acordo com o procedimento efectado para os espĂ©cimes monolĂ­ticos de cada cerĂąmica. Os sessenta (60) espĂ©cimes foram aleatoriamente distribuidos por seis grupos, dois grupos para cada cerĂąmica, cada grupo composto por dez espĂ©cimes. A resistĂȘnicia mĂĄxima Ă  fractura foi medida atravĂ©s do mĂ©todo pistonon- three-ball utilizando uma mĂĄquina de testes mecĂąnicos universal Instron Resumo 245 (Modelo TT-BM Instron Corp., Canton, MA), e de acordo com o standard ISO/DIS 6872 para cerĂąmicas dentĂĄrias (ISO/DIS 6872: 1995). Em trinta (30) espĂ©cimes, dez por cerĂąmica, a força foi aplicada na cerĂąmica felsdpĂĄtica de revestimento. Nos restante trinta (30), dez por cerĂąmica, a força foi aplicada na infra-estrutura de ZircĂłnia. O objectivo de inverter a posição dos espĂ©cimes foi perceber a influĂȘncia que a cerĂąmica de revestimento teria na origem interna ou externa da fractura do material. A mĂĄxima resistĂȘncia Ă  fractura (N) foi registada e conjugada com a seguinte formula (ASTM F 394- 78, 1996), por forma a obter e calcular a resistĂȘncia Ă  flexĂŁo biaxial para cada especime: S = - 0.2387 P(X – Y)/d2 (ISO/DIS 6872: 1995). Conjuntamente foi calculado o Weibull modulus para a resistĂȘncia Ă  flexĂŁo biaxial obtida. A anĂĄlise estatĂ­stica dos resultados foi efectuada atravĂ©s da utilização do mĂ©todo two-way ANOVA com ajustamento de Fisher's PLSD post-hoc e Student’s t-test para comparaçÔes mĂșltiplas (p=0.05), para avaliar as diferenças de resistĂȘncia Ă  fractura entre grupos. ApĂłs os testes de fractura todos os espĂ©cimes foram analisados com um estereomicrocĂłpio (Nikon SMZ-U, Tokyo, Japan) com uma ampliação de X75 no sentido de caracterizar a origem e modo de fractura. A caracterização morfolĂłgica dos diferentes tipos de fractura registados na interface ZircĂłnia/cerĂąmica feldspĂĄtica de revestimento foi efectuada atravĂ©s da utilização de microcopia electrĂłnica de varrimento (SEM) (Amray 1820, Bedford, MA, USA). Seis espĂ©cimes representativos, dois de cada grupo, foram seleccionados e fotografias de diferentes amplitudes foram efectudas. Os resultados para a primeira parte do estudo demonstraram que quando as cerĂąmicas feldspĂĄticas de revestimento sĂŁo analizadas em conjunto, os grupos de desgaste (G) apresentarm diferenças significativas em relação a todos os outros grupos. Foram encontradas tambĂ©m diferenças significativas entre os grupos de controlo (C) e os grupos de polimento/glaze (PG). Nenhuma outra diferença significativa de resistĂȘncia Ă  flexĂŁo biaxial, Resumo 246 entre os restantes grupos de tratamento de superfĂ­cie foi encontrada. Quando as cerĂąmicas feldspĂĄticas de revestimento foram analizadas individualmente, os resultados encontrados da resistĂȘncia Ă  flexĂŁo biaxial entre os diferentes grupos de tratamento de superfĂ­cie, foram mais heterogĂ©neos. No entanto, em todos as cerĂąmicas o tratamento de superfĂ­cie de degaste/corte (G) provocou uma diminuição de resistĂȘncia Ă  flexĂŁo biaxial, e em alguns casos de forma estatisticamente significativa. Estes resultados sugerem que o desgaste da superfĂ­cie destas cerĂąmicas deve ser sempre evitado se nenhum outro tratamento de superfĂ­cie for efectuado posteriormente, uma vez que o desgaste ou corte com instrumento de diamante poderĂĄ criar ou alterar as dimensĂ”es de fissuras ou poros prĂ©existententes diminuindo a resistĂȘncia do material. Pelo contrĂĄrio, os resultados da resistĂȘncia Ă  flexĂŁo biaxial para os tratamentos de superficie de polimento e/ou glaze (GG, GP, GPG, PG) melhoraram a resistĂȘncia Ă  flexĂŁo biaxial dos materiais cerĂąmicos, e em alguns casos de forma estatisticamente significativa. Os resultados sugerem que estes tratamentos de superfĂ­cie limitam os efeitos do desgaste/corte, devido Ă  sua capacidade para melhorar as condiçÔes da superfĂ­cie da cerĂąmica, atravĂ©s da eliminação ou diminuição de defeitos, fissura e/ou poros. Os resultados sugerem que as diferenças de distribuição da resistĂȘncia Ă  flexĂŁo biaxial entre os diferentes grupos de tratamento de superfĂ­cie estĂŁo mais dependentes da rugosidade de superfĂ­cie de cada cerĂąmica e consequentemente do tratamento de superfĂ­cie efectuado, do que com a sua estrutura; excepto quando a estrutura interna do material possa provocar uma concentração de stress superior aquela originada pela rugosidade de superfĂ­cie e/ou a presença de poros ou fissuras. Os resultados encontrados demonstraram tambĂ©m, que os valores obtidos para as cerĂąmicas feldspĂĄticas de revestimento para ZircĂłnia (grupo de controlo), se encontram dentro dos valores que as cerĂąmicas feldspĂĄticas Resumo 247 de revestimento nos sistemas metĂĄlicos apresentam. Os resultados encontrados para o Weibull modulus das trĂȘs cerĂąmicas testadas sĂŁo semelhantes aos valores obtidos para outras cerĂąmicas feldspĂĄticas de revestimento. Valores mais elevados foram encontrados para os grupos de polimento, glaze e de controlo, demonstrando maior homogeneidade de valores obtidos, do que para os grupos de desgaste. Os resultados para a segunda parte do estudo demonstraram que, quando os valores da resistĂȘncia Ă  flexĂŁo biaxial das cerĂąmicas feldspĂĄticas de revestimento/infra-estrutura ZircĂłnia sĂŁo analizadas em conjunto, os espĂ©cimes que foram testados com a infra-estrutura de ZircĂłnia na superfĂ­cie inferior, apresentaram valores estatisticamente superiores aqueles que apresentaram as cerĂąmicas feldspĂĄticas de revestimento sob tensĂŁo. Quando analizadas individualmente apenas a NobelRondoTM Zirconia veneer ceramic nĂŁo demonstrou diferenças significativas independentemente do material que era colocado sob tensĂŁo. Estes resultados demonstram, que o contributo de infra-estruturas mais resistentes no desempenho clĂ­nico de restauraçÔes em cerĂąmica pura, poderĂĄ nĂŁo ser significativo se o desenho da restauração nĂŁo tiver em atenção a distribuição do stress tensional sobre ela exercido. Os resultados encontrados para o Weibull modulus das trĂȘs cerĂąmicas testadas sĂŁo semelhantes aos valores obtidos para outras cerĂąmicas feldspĂĄticas de revestimento quando estratificadas sobre infra-estruturas diferentes da ZircĂłnia. Valores mais elevados foram encontrados para os grupos que apresentavam a ZircĂłnia sob tensĂŁo, evidenciando maior homogeneidade de valores obtidos. Dois modos de fractura diferentes foram predominantemente encontrados nos espĂ©cimes, dependendo do material que era colocado em tensĂŁo. Quando a ZircĂłnia era colocada em tensĂŁo, um cone Hertziano estava presente na superfĂ­cie da cerĂąmica feldspĂĄtica em practicamente todos os espĂ©cimes. A presença deste cone, era acompanhado por traços de Resumo 248 fractura que se propagavam lateralmente causando eventual delaminação parcial da cerĂąmica feldspĂĄtica de revestimento sem fractura da infraestrutura de ZircĂłnia. Pelo contrĂĄrio, quando as cerĂąmicas de revestimento eram colocadas sob tensĂŁo, a fractura

    Nondestructive Testing Methods and New Applications

    Get PDF
    Nondestructive testing enables scientists and engineers to evaluate the integrity of their structures and the properties of their materials or components non-intrusively, and in some instances in real-time fashion. Applying the Nondestructive techniques and modalities offers valuable savings and guarantees the quality of engineered systems and products. This technology can be employed through different modalities that include contact methods such as ultrasonic, eddy current, magnetic particles, and liquid penetrant, in addition to contact-less methods such as in thermography, radiography, and shearography. This book seeks to introduce some of the Nondestructive testing methods from its theoretical fundamentals to its specific applications. Additionally, the text contains several novel implementations of such techniques in different fields, including the assessment of civil structures (concrete) to its application in medicine

    Production Engineering and Management

    Get PDF
    The annual International Conference on Production Engineering and Management takes place for the sixth time his year, and can therefore be considered a well - established event that is the result of the joint effort of the OWL University of Applied Sciences and the University of Trieste. The conference has been established as an annual meeting under the Double Degree Master Program ‘Production Engineering and Management’ by the two partner universities. The main goal of the conference is to provide an opportunity for students, researchers and professionals from Germany, Italy and abroad, to meet and exchange information, discuss experiences, specific practices and technical solutions used in planning, design and management of production and service systems. In addition, the conference is a platform aimed at presenting research projects, introducing young academics to the tradition of Symposiums and promoting the exchange of ideas between the industry and the academy. Especially the contributions of successful graduates of the Double Degree Master Program ‘Production Engineering and Management’ and those of other postgraduate researchers from several European countries have been enforced. This year’s special focus is on Direct Digital Manufacturing in the context of Industry 4.0, a topic of great interest for the global industry. The concept is spreading, but the actual solutions must be presented in order to highlight the practical benefits to industry and customers. Indeed, as Henning Banthien, Secretary General of the German ‘Plattform Industrie 4.0’ project office, has recently remarked, “Industry 4.0 requires a close alliance amongst the private sector, academia, politics and trade unions” in order to be “translated into practice and be implemented now”. PEM 2016 takes place between September 29 and 30, 2016 at the OWL University of Applied Sciences in Lemgo. The program is defined by the Organizing and Scientific Committees and clustered into scientific sessions covering topics of main interest and importance to the participants of the conference. The scientific sessions deal with technical and engineering issues, as well as management topics, and include contributions by researchers from academia and industry. The extended abstracts and full papers of the contributions underwent a double - blind review process. The 24 accepted presentations are assigned, according to their subject, to one of the following sessions: ‘Direct Digital Manufacturing in the Context of Industry 4.0’, ‘Industrial Engineering and Lean Management’, ‘Management Techniques and Methodologies’, ‘Wood Processing Technologies and Furniture Production’ and ‘Innovation Techniques and Methodologies

    Classic Reviews from Past Comprehensive Review Courses in Prosthodontics

    Full text link
    https://deepblue.lib.umich.edu/bitstream/2027.42/154049/1/classic_reviews-vol1.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/154049/2/classic_reviews-vol2.pdfDescription of classic_reviews-vol1.pdf : Volume 1Description of classic_reviews-vol2.pdf : Volume

    Evaluation of the 3D Printing Accuracy of a Dental Model According to Its Internal Structure and Cross-Arch Plate Design: An In Vitro Study

    Get PDF
    The amount of photopolymer material consumed during the three-dimensional (3D) printing of a dental model varies with the volume and internal structure of the modeling data. This study analyzed how the internal structure and the presence of a cross-arch plate influence the accuracy of a 3D printed dental model. The model was designed with a U-shaped arch and the palate removed (Group U) or a cross-arch plate attached to the palate area (Group P), and the internal structure was divided into five types. The trueness and precision were analyzed for accuracy comparisons of the 3D printed models. Two-way ANOVA of the trueness revealed that the accuracy was 135.2 ± 26.3 ”m (mean ± SD) in Group U and 85.6 ± 13.1 ”m in Group P. Regarding the internal structure, the accuracy was 143.1 ± 46.8 ”m in the 1.5 mm-thick shell group, which improved to 111.1 ± 31.9 ”m and 106.7 ± 26.3 ”m in the roughly filled and fully filled models, respectively. The precision was 70.3 ± 19.1 ”m in Group U and 65.0 ± 8.8 ”m in Group P. The results of this study suggest that a cross-arch plate is necessary for the accurate production of a model using 3D printing regardless of its internal structure. In Group U, the error during the printing process was higher for the hollowed models.ope
    • 

    corecore