987 research outputs found

    A multifunctional dynamic voltage restorer for power quality improvement

    Get PDF
    Power quality is a major concern in electrical power systems. The power quality disturbances such as sags, swells, harmonic distortion and other interruptions have an impact on the electrical devices and machines and in severe cases can cause serious damages. Therefore it is necessary to recognize and compensate all types of disturbances at an earliest time to ensure normal and efficient operation of the power system. To solve these problems, many types of power devices are used. At the present time, one of those devices, Dynamic Voltage Restorer (DVR) is the most efficient and effective device used in power distribution systems. In this paper, design and modeling of a new structure and a new control method of multifunctional DVRs for voltage quality correction are presented. The new control method was built in the stationary frame by combining Proportional Resonant controllers and Sequence-Decouple Resonant controllers. The performance of the device and this method under different conditions such as voltage swell, voltage sag due to symmetrical and unsymmetrical short circuit, starting of motors, and voltage distortion are described. Simulation result show the superior capability of the proposed DVR to improve power quality under different operating conditions and the effectiveness of the proposed method. The proposed new DVR controller is able to detect the voltage disturbances and control the converter to inject appropriate voltages independently for each phase and compensate to load voltage through three single-phase transformers.Web of Science116art. no. 135

    Performance Analysis of Photovoltaic Fed Distributed Static Compensator for Power Quality Improvement

    Get PDF
    Owing to rising demand for electricity, shortage of fossil fuels, reliability issues, high transmission and distribution losses, presently many countries are looking forward to integrate the renewable energy sources into existing electricity grid. This kind of distributed generation provides power at a location close to the residential or commercial consumers with low transmission and distribution costs. Among other micro sources, solar photovoltaic (PV) systems are penetrating rapidly due to its ability to provide necessary dc voltage and decreasing capital cost. On the other hand, the distribution systems are confronting serious power quality issues because of various nonlinear loads and impromptu expansion. The power quality issues incorporate harmonic currents, high reactive power burden, and load unbalance and so on. The custom power device widely used to improve these power quality issues is the distributed static compensator (DSTATCOM). For continuous and effective compensation of power quality issues in a grid connected solar photovoltaic distribution system, the solar inverters are designed to operate as a DSTATCOM thus by increasing the efficiency and reducing the cost of the system. The solar inverters are interfaced with grid through an L-type or LCL-type ac passive filters. Due to the voltage drop across these passive filters a high amount of voltage is maintained across the dc-link of the solar inverter so that the power can flow from PV source to grid and an effective compensation can be achieved. So in the thesis a new topology has been proposed for PV-DSTATCOM to reduce the dc-link voltage which inherently reduces the cost and rating of the solar inverter. The new LCLC-type PV-DSTATCOM is implemented both in simulation and hardware for extensive study. From the obtained results, the LCLC-type PV-DSTATCOM found to be more effective than L-type and LCL-type PV-DSTATCOM. Selection of proper reference compensation current extraction scheme plays the most crucial role in DSTATCOM performance. This thesis describes three time-domain schemes viz. Instantaneous active and reactive power (p-q), modified p-q, and IcosΦ schemes. The objective is to bring down the source current THD below 5%, to satisfy the IEEE-519 Standard recommendations on harmonic limits. Comparative evaluation shows that, IcosΦ scheme is the best PV-DSTATCOM control scheme irrespective of supply and load conditions. In the view of the fact that the filtering parameters of the PV-DSTATCOM and gains of the PI controller are designed using a linearized mathematical model of the system. Such a design may not yield satisfactory results under changing operating conditions due to the complex, nonlinear and time-varying nature of power system networks. To overcome this, evolutionary algorithms have been adopted and an algorithm-specific control parameter independent optimization tool (JAYA) is proposed. The JAYA optimization algorithm overcomes the drawbacks of both grenade explosion method (GEM) and teaching learning based optimization (TLBO), and accelerate the convergence of optimization problem. Extensive simulation studies and real-time investigations are performed for comparative assessment of proposed implementation of GEM, TLBO and JAYA optimization on PV-DSTATCOM. This validates that, the PV-DSTATCOM employing JAYA offers superior harmonic compensation compared to other alternatives, by lowering down the source current THD to drastically small values. Another indispensable aspect of PV-DSTATCOM is that due to parameter variation and nonlinearity present in the system, the reference current generated by the reference compensation current extraction scheme get altered for a changing operating conditions. So a sliding mode controller (SMC) based p-q theory is proposed in the dissertation to reduce these effects. To validate the efficacy of the implemented sliding mode controller for the power quality improvement, the performance of the proposed system with both linear and non-linear controller are observed and compared by taking total harmonic distortion as performance index. From the obtained simulation and experimentation results it is concluded that the SMC based LCLC-type PV-DSTATCOM performs better in all critical operating conditions

    Three-phase phase-locked loop synchronization algorithms for grid-connected renewable energy systems:A review

    Get PDF
    The increasing penetration of distributed renewable energy sources (RES) requires appropriate control techniques in order to remain interconnected and contribute in a proper way to the overall grid stability, whenever disturbances occur. In addition, the disconnection of RES due to synchronization problems must be avoided as this may result in penalties and loss of energy generation to RES operators. The control of RES mainly depends on the synchronization algorithm, which should be fast and accurately detect the grid voltage status (e.g., phase, amplitude, and frequency). Typically, phase-locked loop (PLL) synchronization techniques are used for the grid voltage monitoring. The design and performance of PLL directly affect the dynamics of the RES grid side converter (GSC). This paper presents the characteristics, design guidelines and features of advanced state-of-the-art PLL-based synchronization algorithms under normal, abnormal and harmonically-distorted grid conditions. Experimental tests on the selected PLL methods under different grid conditions are presented, followed by a comparative benchmarking and selection guide. Finally, corresponding PLL tuning procedures are discussed.This work was supported by the supported by the Research Promotion Foundation (RPF) of Cyprus under Project KOINA/SOLAR-ERA.NET/1215/06

    Control System Design, Analysis, and Simulation of a Photovoltaic Inverter for Unbalanced Load Compensation in a Microgrid

    Get PDF
    This thesis presents a control scheme for a single-stage three-phase Photovoltaic (PV) converter with negative sequence load current compensation. In this thesis a dual virtual impedance active damping technique for an LCL filter is proposed to address the issue of LCL filter resonance. Both inverter-side current and the capacitor current are used in the feedback loop. Using both signals provides higher DC rejection than using capacitor current alone. The proposed active damping scheme results in a faster transient response and higher damping ratio than can be obtained using inverter-side current alone. The feedback gains can be calculated to achieve a specified damping level. A method of determining the gains of the Proportional and Resonant current controller based on frequency response characteristics is presented. For a specified set of gain and phase margins, the controller gains can be calculated explicitly. Furthermore, a modification is proposed to prevent windup in the resonator. A numerically compensated Half-Cycle Discrete Fourier Transform (HCDFT) method is developed to calculate the negative sequence component of the load current. The numerical compensation allows the HCDFT to accurately estimate the fundamental component of the load current under off-nominal frequency conditions. The proposed HCDFT method is shown to have a quick settling time that is comparable to that obtained with conventional sequence compensation techniques as well as immunity to harmonics in the input signal. The effect of unbalance compensation on the PV power output depending on the irradiance and the operational region on the power-voltage curve is examined. Analysis of the DC link voltage ripple shows the region of operation on the P-V curve affects the amplitude of the DC link voltage ripple during negative sequence compensation. The proposed control scheme is validated by simulation in the Matlab/Simulink® environment. The proposed control scheme is tested in the presence of excessive current imbalance, unbalanced feeder impedances, and non-linear loads. The results have shown that the proposed control scheme can improve power quality in a hybrid PV-diesel microgrid by reducing both voltage and current imbalance while simultaneously converting real power from a PV array

    Flexible active compensation based on load conformity factors applied to non-sinusoidal and asymmetrical voltage conditions

    Get PDF
    This study proposes a flexible active power filter (APF) controller operating selectively to satisfy a set of desired load performance indices defined at the source side. The definition of such indices, and of the corresponding current references, is based on the orthogonal instantaneous current decomposition and conformity factors provided by the conservative power theory. This flexible approach can be applied to single- or three-phase APFs or other grid-tied converters, as those interfacing distributed generators in smart grids. The current controller is based on a modified hybrid P-type iterative learning controller which has shown good steady-state and dynamic performances. To validate the proposed approach, a three-phase four-wire APF connected to a non-linear and unbalanced load has been considered. Experimental results have been generated under ideal and non-ideal voltage sources, showing the effectiveness of the proposed flexible compensation scheme, even for weak grid scenarios

    New techniques to improve power quality and evaluate stability in modern all-electric naval ship power systems

    Get PDF
    This dissertation focuses on two crucial issues in the design and analysis of the power electronic systems on modern all-electric naval ships, i.e., power quality control and stability evaluation. It includes three papers that deal with active power filter topology, active rectifier control, and impedance measurement techniques, respectively. To mitigate harmonic currents generated by high-power high-voltage shipboard loads such as propulsion motor drives, the first paper proposes a novel seven-level shunt active power filter topology, which utilizes tapped reactors for parallel operations of switching devices. The multi-level system has been implemented in both regular digital simulation and real-time digital simulator for validation. In the second paper, a harmonic compensation algorithm for three-phase active rectifiers is proposed. Based on the theory of multiple reference frames, it provides fast and accurate regulation of selected harmonic currents so that the rectifier draws balanced and sinusoidal currents from the source, even when the input voltages are unbalanced and contain harmonics. Extensive laboratory tests on a 2 kW prototype system verifies the effectiveness of the proposed control scheme. The last paper presents a new technique for impedance identification of dc and ac power electronic systems, which significantly simplifies the procedure for stability analysis. Recurrent neural networks are used to build dynamic models of the system based on a few signal injections, then the impedance information can be extracted using off-line training and identification algorithms. Both digital simulation and hardware tests were used to validate the technique --Abstract, page iv

    Active Power Filters in Zero Energy Buildings

    Get PDF
    Master's thesis Renewable Energy ENE500 - University of Agder 2017With an increasing focus on the environment and moving from fossil to renewable energy, there has and is an increasing interest in zero energy buildings. Zero energy buildings often utilize local intermittent renewable energies such as wind and solar energy, and are going to play an important role in the smart grid development with their distributed generation and energy storage etc. In Southern Norway, the smart village Skarpnes is utilizing building integrated photovoltaic systems and is developed for studying zero energy buildings and its impact on electricity demand and power quality. Power electronic based equipment such as uninterruptible power supplies, adjustable speed drives, personal computers and more have all enhanced our daily lives by providing an efficient and reliable way of utilizing the electrical energy. Because of their non-linear behaviour, they are responsible for harmonic currents causing additional losses and harmful effects. In this thesis, a shunt active power filter based on the instantaneous power theory used for power quality improvement is studied. This involves harmonic current, reactive power and neutral current compensation, where load data is obtained from the smart village Skarpnes project. Investigating the operation of the shunt active power filter during import and export of power, during load changes and operation during distorted and unbalanced utility voltage. Based on simulations using MATLAB/Simulink the three-phase, four-wire shunt active power filter is able to compensate the harmonic currents, reactive power and neutral current. The total harmonic distortion in the source current after compensation is below limits proposed by the Institute of Electrical and Electronics Engineers Standard 519-2014 for all test case

    Frequency- adaptive control of a three-phase single-stage grid-connected photovoltaic system under grid voltage sags

    Get PDF
    The low-voltage ride-through service is carried out in this paper according to the voltage profile described by the IEC 61400-21 European normative when short-duration voltage sags happen, and some instantaneous reactive power is delivered to the grid in accordance with the Spanish grid code; the mandatory limitation of the amplitude of the three-phase inverter currents to its nominal value is carried out with a novel control strategy, in which a certain amount of instantaneous constant active power can also be delivered to the grid when small or moderate voltage sags happen. A Multiple second order generalized integrator frequency-locked loop synchronization algorithm is employed in order to estimate the system frequency without harmonic distortions, as well as to output the positive- and the negative- sequence of the αβ quantities of the three-phase grid voltages when balanced and unbalanced voltage sags happen in a frequency- adaptive scheme. The current control is carried out in the stationary reference frame, which guarantees the cancellation of the harmonic distortions in the utility grid currents using a Harmonic compensation structure, and the implementation of a constant active power control in order to protect the DC link capacitor from thermal stresses avoiding the appearance of large harmonic distortions at twice the fundamental frequency in the DC link voltage. A case study of a three-phase single-stage grid-connected PV system with a maximum apparent power about 500 kVA is tested with several simulations using MATLAB/SIMULINK firstly, and secondly, with some experiments using the Controller hardware-in-the-loop (CHIL) simulation technique for several types of voltage sags in order to do the final validation of the control algorithms.This work was supported by the project “Nuevas topologías para convertidores en MT para grandes Instalaciones Fotovoltaicas” from the Spanish Government (Ref. TEC2016-80136-P) (A. B. Rey-Boué) and the European Community’s Horizon 2020 Program (H2020/2014-2020) in project “ERIGrid” (Grant Agreement No. 654113) under the Trans-national Access (TA) User Project: 04.003-201
    corecore