354 research outputs found
Feedback control of unsupported standing in paraplegia. Part I: optimal control approach
This is the first of a pair of papers which describe an investigation into the feasibility of providing artificial balance to paraplegics using electrical stimulation of the paralyzed muscles. By bracing the body above the shanks, only stimulation of the plantarflexors is necessary. This arrangement prevents any influence from the intact neuromuscular system above the spinal cord lesion. Here, the authors extend the design of the controllers to a nested-loop LQG (linear quadratic Gaussian) stimulation controller which has ankle moment feedback (inner loops) and inverted pendulum angle feedback (outer loop). Each control loop is tuned by two parameters, the control weighting and an observer rise-time, which together determine the behavior. The nested structure was chosen because it is robust, despite changes in the muscle properties (fatigue) and interference from spasticity
Recommended from our members
A Generalized Method for Predictive Simulation-Based Lower Limb Prosthesis Design
Lower limb prostheses are designed to replace the functions and form of the missing biological anatomy. These functions are hypothesized to improve user outcome measures which are negatively affected by receiving an amputation – such as metabolic cost of transport, preferred walking speed, and perceived discomfort during walking. However, the effect of these design functions on the targeted outcome measures is highly variable, suggesting that these relationships are not fully understood. Biomechanics simulation and modeling tools are increasingly capable of analyzing the effects of a design on the resulting user gait. In this work, prothesis-aided gait is optimized in simulation to reduce both muscle effort and peak loads on the residual limb using a generalized prosthesis model. Compared to a traditional revolute powered ankle joint model, a two degree-of freedom generalized model reduced muscle activations by 50% and peak loads by 15%. Simulated prosthesis behaviors corresponding to the optimal gait patterns were translated into a two degree-of-freedom ankle-foot prosthesis design with powered bidirectional linear translation and plantarflexion. The prototype is capable of delivering up to 171 N-m of plantarflexion torque and 499 N of translation force, with 15° dorsi-/35° plantarflexion and 10 cm translation range of motion. The mass and height of the ankle-foot are 2.29 kg and 19.5 cm, respectively. The mass of the entire system including the wearable offboard system is 8.58 kg. This platform is designed to emulate the behavior of the simulated prosthesis, as well as be configurable to emulate alternate behaviors obtained from simulations with different optimization objectives. The prototype is controlled to replicate simulated walking patterns using a high level finite state controller, mid-level stiffness controller, and low level load controller. Closed loop load control has bandwidth of 15 Hz in translation and 7.2 Hz in flexion. Load tracking during walking with a single able-bodied human subject ranges from 93 to 159 N in translation and 4.6 to 21.3 N-m in flexion. The contribution of this work is to provide a framework for predictive simulation-based prosthesis design, evidence of its practical implementation, and the experimental tools to validate future predictive simulation studies
Control-based 4D printing: adaptive 4D-printed systems
Building on the recent progress of four-dimensional (4D) printing to produce dynamic structures, this study aimed to bring this technology to the next level by introducing control-based 4D printing to develop adaptive 4D-printed systems with highly versatile multi-disciplinary applications, including medicine, in the form of assisted soft robots, smart textiles as wearable electronics and other industries such as agriculture and microfluidics. This study introduced and analysed adaptive 4D-printed systems with an advanced manufacturing approach for developing stimuli-responsive constructs that organically adapted to environmental dynamic situations and uncertainties as nature does. The adaptive 4D-printed systems incorporated synergic integration of three-dimensional (3D)-printed sensors into 4D-printing and control units, which could be assembled and programmed to transform their shapes based on the assigned tasks and environmental stimuli. This paper demonstrates the adaptivity of these systems via a combination of proprioceptive sensory feedback, modeling and controllers, as well as the challenges and future opportunities they present
Safe Human-Robot Interaction Using Variable Stiffness, Hyper-Redundancy, and Smart Robotic Skins
In service robotics, safe human-robot interaction (HRI) is still an open research topic, requiring developments both in hardware and in software as well as their integration. In UMAY1 and MEDICARE-C2projects, we addressed both mechanism design and perception aspects of a framework for safe HRI. Our first focus was to design variable stiffness joints for the robotic neck and arm to enable inherent compliance to protect a human collaborator. We demonstrate the advantages of variable stiffness actuators (VSA) in compliancy, safety, and energy efficiency with applications in exoskeleton and rehabilitation robotics. The variable-stiffness robotic neck mechanism was later scaled down and adopted in the robotic endoscope featuring hyper-redundancy. The hyper-redundant structures are more controllable, having efficient actuation and better feedback. Lastly, a smart robotic skin is introduced to explain the safety support via enhancement of tactile perception. Although it is developed for a hyper-redundant endoscopic robotic platform, the artificial skin can also be integrated in service robotics to provide multimodal tactile feedback. This chapter gives an overview of systems and their integration to attain a safer HRI. We follow a holistic approach for inherent compliancy via mechanism design (i.e., variable stiffness), precise control (i.e., hyper-redundancy), and multimodal tactile perception (i.e., smart robotic-skins)
Adaptive robust interaction control for low-cost robotic grasping
Robotic grasping is a challenging area in the field of robotics. When a gripper starts interacting with an object to perform a grasp, the mechanical properties of the object (stiffness and damping) will play an important role. A gripper which is stable in isolated conditions, can become unstable when coupled to an object. This can lead to the extreme condition where the gripper becomes unstable and generates excessive or insufficient grip force resulting in the grasped object either being crushed, or falling and breaking. In addition to the stability issue, grasp maintenance is one of the most important requirements of any grasp where it guarantees a secure grasp in the presence of any unknown disturbance. The term grasp maintenance refers to the reaction of the controller in the presence of external disturbances, trying to prevent any undesired slippage. To do so, the controller continuously adjusts the grip force. This is a challenging task as it requires an accurate model of the friction and object’s weight to estimate a sufficient grip force to stop the object from slipping while incurring minimum deformation. Unfortunately, in reality, there is no solution which is able to obtain the mechanical properties, frictional coefficient and weight of an object before establishing a mechanical interaction with it. External disturbance forces are also stochastic meaning they are impossible to predict. This thesis addresses both of the problems mentioned above by:Creating a novel variable stiffness gripper, capable of grasping unknown objects, mainly those found in agricultural or food manufacturing companies. In addition to the stabilisation effect of the introduced variable stiffness mechanism, a novel force control algorithm has been designed that passively controls the grip force in variable stiffness grippers. Due to the passive nature of the suggested controller, it completely eliminates the necessity for any force sensor. The combination of both the proposed variable stiffness gripper and the passivity based control provides a unique solution for the stable grasp and force control problem in tendon driven, angular grippers.Introducing a novel active multi input-multi output slip prevention algorithm. The algorithm developed provides a robust control solution to endow direct drive parallel jaw grippers with the capability to stop held objects from slipping while incurring minimum deformation; this can be done without any prior knowledge of the object’s friction and weight. The large number of experiments provided in this thesis demonstrate the robustness of the proposed controller when controlling parallel jaw grippers in order to quickly grip, lift and place a broad range of objects firmly without dropping or crushing them. This is particularly useful for teleoperation and nuclear decommissioning tasks where there is often no accurate information available about the objects to be handled. This can mean that pre-programming of the gripper is required for each different object and for high numbers of objects this is impractical and overly time-consuming. A robust controller, which is able to compensate for any uncertainties regarding the object model and any unknown external disturbances during grasping, is implemented. This work has advanced the state of the art in the following two main areas: Direct impedance modulation for stable grasping in tendon driven, angular grippers. Active MIMO slip prevention grasp control for direct drive parallel jaw grippers
Humanoid Robots
For many years, the human being has been trying, in all ways, to recreate the complex mechanisms that form the human body. Such task is extremely complicated and the results are not totally satisfactory. However, with increasing technological advances based on theoretical and experimental researches, man gets, in a way, to copy or to imitate some systems of the human body. These researches not only intended to create humanoid robots, great part of them constituting autonomous systems, but also, in some way, to offer a higher knowledge of the systems that form the human body, objectifying possible applications in the technology of rehabilitation of human beings, gathering in a whole studies related not only to Robotics, but also to Biomechanics, Biomimmetics, Cybernetics, among other areas. This book presents a series of researches inspired by this ideal, carried through by various researchers worldwide, looking for to analyze and to discuss diverse subjects related to humanoid robots. The presented contributions explore aspects about robotic hands, learning, language, vision and locomotion
Physical human-robot collaboration: Robotic systems, learning methods, collaborative strategies, sensors, and actuators
This article presents a state-of-the-art survey on the robotic systems, sensors, actuators, and collaborative strategies for physical human-robot collaboration (pHRC). This article starts with an overview of some robotic systems with cutting-edge technologies (sensors and actuators) suitable for pHRC operations and the intelligent assist devices employed in pHRC. Sensors being among the essential components to establish communication between a human and a robotic system are surveyed. The sensor supplies the signal needed to drive the robotic actuators. The survey reveals that the design of new generation collaborative robots and other intelligent robotic systems has paved the way for sophisticated learning techniques and control algorithms to be deployed in pHRC. Furthermore, it revealed the relevant components needed to be considered for effective pHRC to be accomplished. Finally, a discussion of the major advances is made, some research directions, and future challenges are presented
- …