8 research outputs found

    Trajectory Generation for Hip Rehabilitation Exoskeleton Using Trajectory

    Get PDF
    A walking rehabilitation exoskeleton robot is used for patient having walking difficulty to undergo walking therapy by wearing it on his lower body. If the rehabilitation is done directly by using  predefined normal gait, the patient can feel discomfort and may lead to painful therapy. This can also endangered the patient limb under therapy. Due to that reason, the patient will be discouraged and unmotivated to proceed with the therapy. This paper presents the hip trajectory generation by utilizing the patient current trajectory that morphs into the target trajectory by generating a sequence of gradually changing hip trajectories

    Design and Voluntary Motion Intention Estimation of a Novel Wearable Full-Body Flexible Exoskeleton Robot

    Get PDF

    Validity and Consistency of Concurrent Extraction of Gait Features Using Inertial Measurement Units and Motion Capture System

    Get PDF
    Conditions causing gait abnormalities are very common and their treatment requires the detailed assessment of gait. Currently such assessments are carried out in gait laboratories and require the use of complex and expensive equipment. To increase availability and use at home and clinics, we design and develop an affordable, user friendly, wireless, portable automatic system to extract spatiotemporal features of gait that can be used indoors and outdoors. This study determines the concurrent validity of extracted gait features from Inertial Measurement Units (IMUs) against ‘gold standard’ Motion Capture System (MoCap) using a hybrid gait features extraction method. The analysis of the proposed method is based on minimum prominence and abrupt transition points in the IMU signals. We also compare the degree of agreement for mean spatiotemporal gait features. The concurrent data from synchronized IMUs and MoCap are collected from 18 subjects. We validate our proposed system using two experiments; 1) IMU and MoCap with self-selected (free) walking and 2) IMU and MoCap at various walking speeds. Interclass correlations, Lin’s concordance correlation coefficients and Pearson’s correlation coefficients (r) are applied to determine the correlation between extracted gait features from IMU and MoCap measurements. Bland-Altman plots are also generated to evaluate any unknown bias between the mean extracted features. The experiments show that spatiotemporal features of gait extracted from IMUs are highly valid. Our methods facilitate gait assessment in clinics and at home including the possibility of self-assessment

    Gait Evaluation Using Procrustes and Euclidean Distance Matrix Analysis

    Get PDF
    Objective assessment of gait is important in the treatment and rehabilitation of patients with different diseases. In this paper, we propose a gait evaluation system using Procrustes and Euclidean distance matrix analysis. We design and develop an android app to collect real time synchronous accelerometer and gyroscope data from two Inertial Measurement Unit (IMU) sensors through Bluetooth connectivity. The data is collected from 12 young (10 for modelling and 2 for validation) and 20 older subjects. We analyse the data collected from real world for stride, step, stance and swing gait features. We validate our method with measurements of gait features. Generalized Procrustes analysis is used to estimate a standard normal mean gait shape (NMGS) for 10 young subjects. Each gait feature of both young and older subjects is then converted to find the best match with the NMGS using ordinary Procrustes analysis. The shape distance between the NMGS and each gait shape is estimated using Riemannian shape distance, Riemannian size-and-shape distance, Procrustes size-and-shape distance and Root mean square deviation. A t-test is performed to provide statistical evidence of gait shape differences between young and older gaits. A mean form which is considered as a standard normal mean gait form (NMGF) and inter-feature distances are estimated from the set of 10 young subjects. The form difference is estimated between the NMGF and individual gaits of young and older. The degree of abnormality is then estimated for individual features and the result is plotted to visualize the feature in a gait. Experimental results demonstrate the performance of the proposed method

    Gait Phase Recognition for Lower-Limb Exoskeleton with Only Joint Angular Sensors

    No full text
    Gait phase is widely used for gait trajectory generation, gait control and gait evaluation on lower-limb exoskeletons. So far, a variety of methods have been developed to identify the gait phase for lower-limb exoskeletons. Angular sensors on lower-limb exoskeletons are essential for joint closed-loop controlling; however, other types of sensors, such as plantar pressure, attitude or inertial measurement unit, are not indispensable.Therefore, to make full use of existing sensors, we propose a novel gait phase recognition method for lower-limb exoskeletons using only joint angular sensors. The method consists of two procedures. Firstly, the gait deviation distances during walking are calculated and classified by Fisher’s linear discriminant method, and one gait cycle is divided into eight gait phases. The validity of the classification results is also verified based on large gait samples. Secondly, we build a gait phase recognition model based on multilayer perceptron and train it with the phase-labeled gait data. The experimental result of cross-validation shows that the model has a 94.45% average correct rate of set (CRS) and an 87.22% average correct rate of phase (CRP) on the testing set, and it can predict the gait phase accurately. The novel method avoids installing additional sensors on the exoskeleton or human body and simplifies the sensory system of the lower-limb exoskeleton

    人のつま先制御能力を向上させる歩行訓練ロボットの適応的な介入手法の提案

    Get PDF
    早大学位記番号:新8439早稲田大

    An automatic wearable multi-sensor based gait analysis system for older adults.

    Get PDF
    Gait abnormalities in older adults are very common in clinical practice. They lead to serious adverse consequences such as falls and injury resulting in increased care cost. There is therefore a national imperative to address this challenge. Currently gait assessment is done using standardized clinical tools dependent on subjective evaluation. More objective gold standard methods (motion capture systems such as Qualisys and Vicon) to analyse gait rely on access to expensive complex equipment based in gait laboratories. These are not widely available for several reasons including a scarcity of equipment, need for technical staff, need for patients to attend in person, complicated time consuming procedures and overall expense. To broaden the use of accurate quantitative gait monitoring and assessment, the major goal of this thesis is to develop an affordable automatic gait analysis system that will provide comprehensive gait information and allow use in clinic or at home. It will also be able to quantify and visualize gait parameters, identify gait variables and changes, monitor abnormal gait patterns of older people in order to reduce the potential for falling and support falls risk management. A research program based on conducting experiments on volunteers is developed in collaboration with other researchers in Bournemouth University, The Royal Bournemouth Hospital and care homes. This thesis consists of five different studies toward addressing our major goal. Firstly, a study on the effects on sensor output from an Inertial Measurement Unit (IMU) attached to different anatomical foot locations. Placing an IMU over the bony prominence of the first cuboid bone is the best place as it delivers the most accurate data. Secondly, an automatic gait feature extraction method for analysing spatiotemporal gait features which shows that it is possible to extract gait features automatically outside of a gait laboratory. Thirdly, user friendly and easy to interpret visualization approaches are proposed to demonstrate real time spatiotemporal gait information. Four proposed approaches have the potential of helping professionals detect and interpret gait asymmetry. Fourthly, a validation study of spatiotemporal IMU extracted features compared with gold standard Motion Capture System and Treadmill measurements in young and older adults is conducted. The results obtained from three experimental conditions demonstrate that our IMU gait extracted features are highly valid for spatiotemporal gait variables in young and older adults. In the last study, an evaluation system using Procrustes and Euclidean distance matrix analysis is proposed to provide a comprehensive interpretation of shape and form differences between individual gaits. The results show that older gaits are distinguishable from young gaits. A pictorial and numerical system is proposed which indicates whether the assessed gait is normal or abnormal depending on their total feature values. This offers several advantages: 1) it is user friendly and is easy to set up and implement; 2) it does not require complex equipment with segmentation of body parts; 3) it is relatively inexpensive and therefore increases its affordability decreasing health inequality; and 4) its versatility increases its usability at home supporting inclusivity of patients who are home bound. A digital transformation strategy framework is proposed where stakeholders such as patients, health care professionals and industry partners can collaborate through development of new technologies, value creation, structural change, affordability and sustainability to improve the diagnosis and treatment of gait abnormalities