    Analytic description of the image to patient torso registration problem in image guided interventions

    Get PDF
    Objective: The accurate registration of virtual pre-operative information of the human body anatomy, obtained as images with imaging devices, with real intra-operative information is one of the key aspects on which effective Image Guided Surgery (IGS) is based. The registration of pre-operative images on the real patient, during abdominal and thoracic interventions, is influenced by many parameters, which in many cases are influenced each other, thus making it often difficult to define the problem and consequently to solve it for each specific kind of intervention. The objective of this paper is to obtain an analytic description of the 3D image to patient registration problem, which can be more intuitive than the traditional textual descriptions. Methods: The problem is formalized and various parameters affecting the registration are macro-classified in function of their nature. Results: The problem is analytically described discussing for each macro-category of parameters potential solutions to avoid or to reduce their contribution to the registration error. Conclusions: The availability of an analytic description of the image to patient torso registration problem can be beneficial for teaching IGS, to describe existing registration strategies, and to search new ones for each kind of surgery using a systematic approach

    Neurosurgical Ultrasound Pose Estimation Using Image-Based Registration and Sensor Fusion - A Feasibility Study

    Get PDF
    Modern neurosurgical procedures often rely on computer-assisted real-time guidance using multiple medical imaging modalities. State-of-the-art commercial products enable the fusion of pre-operative with intra-operative images (e.g., magnetic resonance [MR] with ultrasound [US] images), as well as the on-screen visualization of procedures in progress. In so doing, US images can be employed as a template to which pre-operative images can be registered, to correct for anatomical changes, to provide live-image feedback, and consequently to improve confidence when making resection margin decisions near eloquent regions during tumour surgery. In spite of the potential for tracked ultrasound to improve many neurosurgical procedures, it is not widely used. State-of-the-art systems are handicapped by optical tracking’s need for consistent line-of-sight, keeping tracked rigid bodies clean and rigidly fixed, and requiring a calibration workflow. The goal of this work is to improve the value offered by co-registered ultrasound images without the workflow drawbacks of conventional systems. The novel work in this thesis includes: the exploration and development of a GPU-enabled 2D-3D multi-modal registration algorithm based on the existing LC2 metric; and the use of this registration algorithm in the context of a sensor and image-fusion algorithm. The work presented here is a motivating step in a vision towards a heterogeneous tracking framework for image-guided interventions where the knowledge from intraoperative imaging, pre-operative imaging, and (potentially disjoint) wireless sensors in the surgical field are seamlessly integrated for the benefit of the surgeon. The technology described in this thesis, inspired by advances in robot localization demonstrate how inaccurate pose data from disjoint sources can produce a localization system greater than the sum of its parts

    Technical Approaches toComputer-Assisted Orthopedic Surgery

    Get PDF
    Abstract : Surgical navigation systems and medical robotic devices are increasingly being used during trauma and orthopedic surgery. This article tries to present the underlying technology of these devices and to describe different approaches to the various aspects of the methods. To structure the variety of available products and presented research modules, a new categorization for these approaches is proposed. Examples of pre- or intraoperative imaging modalities, of trackers for navigation systems, of different surgical robots, and of methods for registration as well as referencing are discussed. Many applications that have been realized for numerous surgical procedures will be presented and their advantages, disadvantages, and possible implications will be elucidate

    Toward real-time rigid registration of intra-operative ultrasound with preoperative CT images for lumbar spinal fusion surgery

    Get PDF
    Purpose Accurate and effective registration of the vertebrae is crucial for spine surgical navigation procedures. Patient movement, surgical instrumentation or inadvertent contact with the tracked reference during the intervention may invalidate the registration, requiring a rapid correction of the misalignment. In this paper, we present a framework to rigidly align preoperative computed tomography (CT) with the intra-operative ultrasound (iUS) images of a single vertebra. Methods We use a single caudo-cranial axial sweep procedure to acquire iUS images, from which the scan trajectory is exploited to initialize the registration transform. To refine the transform, locations of the posterior vertebra surface are first extracted, then used to compute the CT-to-iUS image intensity gradient-based alignment. The approach was validated on a lumbosacral section of a porcine cadaver. Results We achieved an overall median accuracy of 1.48 mm (success rate of 84.42%) in ~11 s of computation time, satisfying the clinically accepted accuracy threshold of 2 mm. Conclusion Our approach using intra-operative ultrasound to register patient vertebral anatomy to preoperative images matches the clinical needs in terms of accuracy and computation time, facilitating its integration into the surgical workflow

    Open-source software for ultrasound-based guidance in spinal fusion surgery.

    Get PDF
    Spinal instrumentation and surgical manipulations may cause loss of navigation accuracy requiring an efficient re-alignment of the patient anatomy with pre-operative images during surgery. While intra-operative ultrasound (iUS) guidance has shown clear potential to reduce surgery time, compared with clinical computed tomography (CT) guidance, rapid registration aiming to correct for patient misalignment has not been addressed. In this article, we present an open-source platform for pedicle screw navigation using iUS imaging. The alignment method is based on rigid registration of CT to iUS vertebral images and has been designed for fast and fully automatic patient re-alignment in the operating room. Two steps are involved: first, we use the iUS probe's trajectory to achieve an initial coarse registration; then, the registration transform is refined by simultaneously optimizing gradient orientation alignment and mean of iUS intensities passing through the CT-defined posterior surface of the vertebra. We evaluated our approach on a lumbosacral section of a porcine cadaver with seven vertebral levels. We achieved a median target registration error of 1.47 mm (100% success rate, defined by a target registration error <2 mm) when applying the probe's trajectory initial alignment. The approach exhibited high robustness to partial visibility of the vertebra with success rates of 89.86% and 88.57% when missing either the left or right part of the vertebra and robustness to initial misalignments with a success rate of 83.14% for random starts within ±20° rotation and ±20 mm translation. Our graphics processing unit implementation achieves an efficient registration time under 8 s, which makes the approach suitable for clinical application

    The state-of-the-art in ultrasound-guided spine interventions.

    Get PDF
    During the last two decades, intra-operative ultrasound (iUS) imaging has been employed for various surgical procedures of the spine, including spinal fusion and needle injections. Accurate and efficient registration of pre-operative computed tomography or magnetic resonance images with iUS images are key elements in the success of iUS-based spine navigation. While widely investigated in research, iUS-based spine navigation has not yet been established in the clinic. This is due to several factors including the lack of a standard methodology for the assessment of accuracy, robustness, reliability, and usability of the registration method. To address these issues, we present a systematic review of the state-of-the-art techniques for iUS-guided registration in spinal image-guided surgery (IGS). The review follows a new taxonomy based on the four steps involved in the surgical workflow that include pre-processing, registration initialization, estimation of the required patient to image transformation, and a visualization process. We provide a detailed analysis of the measurements in terms of accuracy, robustness, reliability, and usability that need to be met during the evaluation of a spinal IGS framework. Although this review is focused on spinal navigation, we expect similar evaluation criteria to be relevant for other IGS applications

    Robot-Assisted Image-Guided Interventions

    Get PDF
    Image guidance is a common methodology of minimally invasive procedures. Depending on the type of intervention, various imaging modalities are available. Common imaging modalities are computed tomography, magnetic resonance tomography, and ultrasound. Robotic systems have been developed to enable and improve the procedures using these imaging techniques. Spatial and technological constraints limit the development of versatile robotic systems. This paper offers a brief overview of the developments of robotic systems for image-guided interventions since 2015 and includes samples of our current research in this field

    Robot-Assisted Image-Guided Interventions

    Get PDF
    Image guidance is a common methodology of minimally invasive procedures. Depending on the type of intervention, various imaging modalities are available. Common imaging modalities are computed tomography, magnetic resonance tomography, and ultrasound. Robotic systems have been developed to enable and improve the procedures using these imaging techniques. Spatial and technological constraints limit the development of versatile robotic systems. This paper offers a brief overview of the developments of robotic systems for image-guided interventions since 2015 and includes samples of our current research in this field
    • …
    corecore