3,478 research outputs found
Dynamic modeling, property investigation, and adaptive controller design of serial robotic manipulators modeled with structural compliance
Research results on general serial robotic manipulators modeled with structural compliances are presented. Two compliant manipulator modeling approaches, distributed and lumped parameter models, are used in this study. System dynamic equations for both compliant models are derived by using the first and second order influence coefficients. Also, the properties of compliant manipulator system dynamics are investigated. One of the properties, which is defined as inaccessibility of vibratory modes, is shown to display a distinct character associated with compliant manipulators. This property indicates the impact of robot geometry on the control of structural oscillations. Example studies are provided to illustrate the physical interpretation of inaccessibility of vibratory modes. Two types of controllers are designed for compliant manipulators modeled by either lumped or distributed parameter techniques. In order to maintain the generality of the results, neither linearization is introduced. Example simulations are given to demonstrate the controller performance. The second type controller is also built for general serial robot arms and is adaptive in nature which can estimate uncertain payload parameters on-line and simultaneously maintain trajectory tracking properties. The relation between manipulator motion tracking capability and convergence of parameter estimation properties is discussed through example case studies. The effect of control input update delays on adaptive controller performance is also studied
Biomechanics
Biomechanics is a vast discipline within the field of Biomedical Engineering. It explores the underlying mechanics of how biological and physiological systems move. It encompasses important clinical applications to address questions related to medicine using engineering mechanics principles. Biomechanics includes interdisciplinary concepts from engineers, physicians, therapists, biologists, physicists, and mathematicians. Through their collaborative efforts, biomechanics research is ever changing and expanding, explaining new mechanisms and principles for dynamic human systems. Biomechanics is used to describe how the human body moves, walks, and breathes, in addition to how it responds to injury and rehabilitation. Advanced biomechanical modeling methods, such as inverse dynamics, finite element analysis, and musculoskeletal modeling are used to simulate and investigate human situations in regard to movement and injury. Biomechanical technologies are progressing to answer contemporary medical questions. The future of biomechanics is dependent on interdisciplinary research efforts and the education of tomorrow’s scientists
Recommended from our members
Time-of-flight resolved light field fluctuations reveal deep human tissue physiology.
Red blood cells (RBCs) transport oxygen to tissues and remove carbon dioxide. Diffuse optical flowmetry (DOF) assesses deep tissue RBC dynamics by measuring coherent fluctuations of multiply scattered near-infrared light intensity. While classical DOF measurements empirically correlate with blood flow, they remain far-removed from light scattering physics and difficult to interpret in layered media. To advance DOF measurements closer to the physics, here we introduce an interferometric technique, surmounting challenges of bulk motion to apply it in awake humans. We reveal two measurement dimensions: optical phase, and time-of-flight (TOF), the latter with 22 picosecond resolution. With this multidimensional data, we directly confirm the unordered, or Brownian, nature of optically probed RBC dynamics typically assumed in classical DOF. We illustrate how incorrect absorption assumptions, anisotropic RBC scattering, and layered tissues may confound classical DOF. By comparison, our direct method enables accurate and comprehensive assessment of blood flow dynamics in humans
Upper Limb Posture Estimation in Robotic and Virtual Reality-based Rehabilitation.
New motor rehabilitation therapies include virtual reality (VR) and robotic technologies. In limb rehabilitation, limb posture is required to (1) provide a limb realistic representation in VR games and (2) assess the patient improvement. When exoskeleton devices are used in the therapy, the measurements of their joint angles cannot be directly used to represent the posture of the patient limb, since the human and exoskeleton kinematic models differ. In response to this shortcoming, we propose a method to estimate the posture of the human limb attached to the exoskeleton. We use the exoskeleton joint angles measurements and the constraints of the exoskeleton on the limb to estimate the human limb joints angles. This paper presents (a) the mathematical formulation and solution to the problem, (b) the implementation of the proposed solution on a commercial exoskeleton system for the upper limb rehabilitation, (c) its integration into a rehabilitation VR game platform, and (d) the quantitative assessment of the method during elbow and wrist analytic training. Results show that this method properly estimates the limb posture to (i) animate avatars that represent the patient in VR games and (ii) obtain kinematic data for the patient assessment during elbow and wrist analytic rehabilitation
Sonomyography : monitoring morphological changes of forearm muscles in actions with the feasibility for the control of powered prosthesis
Author name used in this publication: Y. P. ZhengAuthor name used in this publication: M. M. Fa. ChanAuthor name used in this publication: J. ShiAuthor name used in this publication: X. ChenAuthor name used in this publication: Q. H. Huang2006-2007 > Academic research: refereed > Publication in refereed journalAccepted ManuscriptPublishe
Validation and application of a computational model for wrist and hand movements using surface markers
A kinematic model is presented based on surface marker placement generating wrist, metacarpal arch, fingers and thumb movements. Standard calculations are used throughout the model and then applied to the specified marker placement. A static trial involving eight unimpaired participants was carried out to assess inter-rater reliability. The standard deviations across the data were comparable to manual goniometers. In addition, a test retest trial of ten unimpaired participants is also reported to illustrate the variability of movement at the wrist joint, metacarpal arch, and index finger as an example of model output when repeating the same task many times. Light and heavyweight versions of the tasks are assessed and characteristics of individual movement strategies presented. The participant trial showed moderate correlation in radial/ulnar deviation of the wrist ( = 0 65), and strong correlation in both metacarpal arch joints ( = 075 and = 085), the MCP ( = 079), and PIP ( = 087) joints of the index finger. The results indicate that individuals use repeated strategies of movement when lifting light and heavyweight versions of the same object, but showed no obvious repeated pattern of movement across the population
A flexible sensor technology for the distributed measurement of interaction pressure
We present a sensor technology for the measure of the physical human-robot interaction pressure developed in the last years at Scuola Superiore Sant'Anna. The system is composed of flexible matrices of opto-electronic sensors covered by a soft silicone cover. This sensory system is completely modular and scalable, allowing one to cover areas of any sizes and shapes, and to measure different pressure ranges. In this work we present the main application areas for this technology. A first generation of the system was used to monitor human-robot interaction in upper- (NEUROExos; Scuola Superiore Sant'Anna) and lower-limb (LOPES; University of Twente) exoskeletons for rehabilitation. A second generation, with increased resolution and wireless connection, was used to develop a pressure-sensitive foot insole and an improved human-robot interaction measurement systems. The experimental characterization of the latter system along with its validation on three healthy subjects is presented here for the first time. A perspective on future uses and development of the technology is finally drafted
Validity of a simple videogrammetric method to measure the movement of all hand segments for clinical purposes
Hand movement measurement is important in clinical, ergonomics and biomechanical
fields. Videogrammetric techniques allow the measurement of hand movement without
interfering the natural hand behaviour. However, an accurate measurement of the
hand movement requires the use of a high number of markers, which limits its
applicability for the clinical practice (60 markers would be needed for hand and wrist).
In this work, a simple method that uses a reduced number of markers (29), based on a
simplified kinematic model of the hand, is proposed and evaluated. A set of
experiments has been performed to evaluate the errors associated to the kinematic
simplification, together with the evaluation of its accuracy, repeatability and
reproducibility. The global error attributed to the kinematic simplification was 6.68º.
The method has small errors in repeatability and reproducibility (3.43º and 4.23º,
respectively) and shows no statistically significant difference with the use of electronic
goniometers. The relevance of the work lies in the ability of measuring all degrees of
freedom of the hand with a reduced number of markers without interfering the natural
hand behaviour, which makes it suitable for its use in clinical applications, as well as
for ergonomic and biomechanical purposes
- …