51,370 research outputs found

    High-response hydraulic linear drive with integrated motion sensor and digital valve control

    Get PDF
    Main purpose of the paper is to present high-response hydraulic linear drive, which is controlled with new digital piezo valve and where the new position transducer is integrated as a part of hydraulic cylinder. Hydraulic digital piezo valve with main static and dynamic characteristics as well as its functionality is presented in detail. The main static and dynamic characteristics of dygital piezo valve which influence directly on the linear drive performance are high resolution of the volume flow rate and high resposne of the valve. Beside valve characteristics the new integrated position transducer, the digital controller and control method, presented in the paper, have major impact on linear drive preformance. At the end of the paper the step response and position resolution of the hydraulic linear drive controlled with the new digital valve is compared with the results of reference hydraulic drive controlled with high response proportional valve

    The high frequency flexural ultrasonic transducer for transmitting and receiving ultrasound in air

    Get PDF
    Flexural ultrasonic transducers are robust and low cost sensors that are typically used in industry for distance ranging, proximity sensing and flow measurement. The operating frequencies of currently available commercial flexural ultrasonic transducers are usually below 50 kHz. Higher operating frequencies would be particularly beneficial for measurement accuracy and detection sensitivity. In this paper, design principles of High Frequency Flexural Ultrasonic Transducers (HiFFUTs), guided by the classical plate theory and finite element analysis, are reported. The results show that the diameter of the piezoelectric disc element attached to the flexing plate of the HiFFUT has a significant influence on the transducer's resonant frequency, and that an optimal diameter for a HiFFUT transmitter alone is different from that for a pitch-catch ultrasonic system consisting of both a HiFFUT transmitter and a receiver. By adopting an optimal piezoelectric diameter, the HiFFUT pitch-catch system can produce an ultrasonic signal amplitude greater than that of a non-optimised system by an order of magnitude. The performance of a prototype HiFFUT is characterised through electrical impedance analysis, laser Doppler vibrometry, and pressure-field microphone measurement, before the performance of two new HiFFUTs in a pitch-catch configuration is compared with that of commercial transducers. The prototype HiFFUT can operate efficiently at a frequency of 102.1 kHz as either a transmitter or a receiver, with comparable output amplitude, wider bandwidth, and higher directivity than commercially available transducers of similar construction

    Differential temperature sensors: Review of applications in the test and characterization of circuits, usage and design methodology

    Get PDF
    Differential temperature sensors can be placed in integrated circuits to extract a signature ofthe power dissipated by the adjacent circuit blocks built in the same silicon die. This review paper firstdiscusses the singularity that differential temperature sensors provide with respect to other sensortopologies, with circuit monitoring being their main application. The paper focuses on the monitoringof radio-frequency analog circuits. The strategies to extract the power signature of the monitoredcircuit are reviewed, and a list of application examples in the domain of test and characterizationis provided. As a practical example, we elaborate the design methodology to conceive, step bystep, a differential temperature sensor to monitor the aging degradation in a class-A linear poweramplifier working in the 2.4 GHz Industrial Scientific Medical—ISM—band. It is discussed how,for this particular application, a sensor with a temperature resolution of 0.02 K and a high dynamicrange is required. A circuit solution for this objective is proposed, as well as recommendations for thedimensions and location of the devices that form the temperature sensor. The paper concludes with adescription of a simple procedure to monitor time variability.Postprint (published version

    Handbook of recommended practices for the determination of liquid monopropellant rocket engine performance

    Get PDF
    The design, installation, and operation of systems to be used for directly measuring quantities of fundamental importance to the determination of monopropellant thruster performance is described. Areas covered include: (1) force and impulse measurement; (2) propellant mass usage and flow measurement; (3) pressure measurement; (4) temperature measurement; (5) exhaust gas composition measurement; and (6) data reduction and performance determination

    An airfoil pitch apparatus-modeling and control design

    Get PDF
    The study of dynamic stall of rapidly pitching airfoils is being conducted at NASA Ames Research Center. Understanding this physical phenomenon will aid in improving the maneuverability of fighter aircraft as well as civilian aircraft. A wind tunnel device which can linearly pitch and control an airfoil with rapid dynamic response is needed for such tests. To develop a mechanism capable of high accelerations, an accurate model and control system is created. The model contains mathematical representations of the mechanical system, including mass, spring, and damping characteristics for each structural element, as well as coulomb friction and servovalve saturation. Electrical components, both digital and analog, linear and nonlinear, are simulated. The implementation of such a high-performance system requires detailed control design as well as state-of-the-art components. This paper describes the system model, states the system requirements, and presents results of its theoretical performance which maximizes the structural and hydraulic aspects of this system

    Linear and Nonlinear Encoding Properties of an Identified Mechanoreceptor on the Fly wing Measured with Mechanical Noise Stimuli

    Get PDF
    The wing blades of most flies contain a small set of distal campaniform sensilla, mechanoreceptors that respond to deformations of the cuticle. This paper describes a method of analysis based upon mechanical noise stimuli which is used to quantify the encoding properties of one of these sensilla (the d-HCV cell) on the wing of the blowfly Calliphora vomitoria (L.). The neurone is modelled as two components, a linear filter that accounts for the frequency response and phase characteristics of the cell, followed by a static nonlinearity that limits the spike discharge to a narrow portion of the stimulus cycle. The model is successful in predicting the response of campaniform neurones to arbitrary stimuli, and provides a convenient method for quantifying the encoding properties of the sensilla. The d-HCV neurone is only broadly frequency tuned, but its maximal response near 150 Hz corresponds to the wingbeat frequency of Calliphora. In the range of frequencies likely to be encountered during flight, the d-HCV neurone fires a single phase-locked action potential for each stimulus cycle. The phase lag of the cell decreases linearly with increasing frequency such that the absolute delay between stimulus and response remains nearly constant. Thus, during flight the neurone is capable of firing one precisely timed action potential during each wingbeat, and might be used to modulate motor activity that requires afferent input on a cycle-by-cycle basis

    Real-time computer data system for the 40- by 80-foot wind tunnel facility at Ames Research Center

    Get PDF
    The background material and operational concepts of a computer-based system for an operating wind tunnel are described. An on-line real-time computer system was installed in a wind tunnel facility to gather static and dynamic data. The computer system monitored aerodynamic forces and moments of periodic and quasi-periodic functions, and displayed and plotted computed results in real time. The total system is comprised of several off-the-shelf, interconnected subsystems that are linked to a large data processing center. The system includes a central processor unit with 32,000 24-bit words of core memory, a number of standard peripherals, and several special processors; namely, a dynamic analysis subsystem, a 256-channel PCM-data subsystem and ground station, a 60-channel high-speed data acquisition subsystem, a communication link, and static force and pressure subsystems. The role of the test engineer as a vital link in the system is also described

    Pulse analysis of acoustic emission signals

    Get PDF
    A method for the signature analysis of pulses in the frequency domain and the time domain is presented. Fourier spectrum, Fourier transfer function, shock spectrum and shock spectrum ratio were examined in the frequency domain analysis, and pulse shape deconvolution was developed for use in the time domain analysis. Comparisons of the relative performance of each analysis technique are made for the characterization of acoustic emission pulses recorded by a measuring system. To demonstrate the relative sensitivity of each of the methods to small changes in the pulse shape, signatures of computer modeled systems with analytical pulses are presented. Optimization techniques are developed and used to indicate the best design parameters values for deconvolution of the pulse shape. Several experiments are presented that test the pulse signature analysis methods on different acoustic emission sources. These include acoustic emissions associated with: (1) crack propagation, (2) ball dropping on a plate, (3) spark discharge and (4) defective and good ball bearings. Deconvolution of the first few micro-seconds of the pulse train are shown to be the region in which the significant signatures of the acoustic emission event are to be found

    A dynamic pressure source for the calibration of pressure transducers

    Get PDF
    A dynamic pressure source is described for producing sinusoidally varying pressures of up to 34 kPa zero to peak, over the frequency range of approximately 50 Hz to 2 kHz. The source is intended for the dynamic calibration of pressure transducers. The transducer to be calibrated is mounted near the base of the thick walled aluminum tube forming the vessel so that the pressure sensitive element is in contact with the liquid in the tube. A section of the tube is filled with small steel balls to damp the motion of the 10-St dimethyl siloxane working fluid in order to extend the useful frquency range to higher frequencies than would be provided by an undamped system. The dynamic response of six transducers provided by the sponsor was evaluated using the pressure sources; the results of these calibrations are given

    Pulse analysis of acoustic emission signals

    Get PDF
    A method for the signature analysis of pulses in the frequency domain and the time domain is presented. Fourier spectrum, Fourier transfer function, shock spectrum and shock spectrum ratio were examined in the frequency domain analysis and pulse shape deconvolution was developed for use in the time domain analysis. Comparisons of the relative performance of each analysis technique are made for the characterization of acoustic emission pulses recorded by a measuring system. To demonstrate the relative sensitivity of each of the methods to small changes in the pulse shape, signatures of computer modeled systems with analytical pulses are presented. Optimization techniques are developed and used to indicate the best design parameter values for deconvolution of the pulse shape. Several experiments are presented that test the pulse signature analysis methods on different acoustic emission sources. These include acoustic emission associated with (a) crack propagation, (b) ball dropping on a plate, (c) spark discharge, and (d) defective and good ball bearings. Deconvolution of the first few micro-seconds of the pulse train is shown to be the region in which the significant signatures of the acoustic emission event are to be found
    corecore