2,406 research outputs found
The NASA SBIR product catalog
The purpose of this catalog is to assist small business firms in making the community aware of products emerging from their efforts in the Small Business Innovation Research (SBIR) program. It contains descriptions of some products that have advanced into Phase 3 and others that are identified as prospective products. Both lists of products in this catalog are based on information supplied by NASA SBIR contractors in responding to an invitation to be represented in this document. Generally, all products suggested by the small firms were included in order to meet the goals of information exchange for SBIR results. Of the 444 SBIR contractors NASA queried, 137 provided information on 219 products. The catalog presents the product information in the technology areas listed in the table of contents. Within each area, the products are listed in alphabetical order by product name and are given identifying numbers. Also included is an alphabetical listing of the companies that have products described. This listing cross-references the product list and provides information on the business activity of each firm. In addition, there are three indexes: one a list of firms by states, one that lists the products according to NASA Centers that managed the SBIR projects, and one that lists the products by the relevant Technical Topics utilized in NASA's annual program solicitation under which each SBIR project was selected
NASA SBIR abstracts of 1991 phase 1 projects
The objectives of 301 projects placed under contract by the Small Business Innovation Research (SBIR) program of the National Aeronautics and Space Administration (NASA) are described. These projects were selected competitively from among proposals submitted to NASA in response to the 1991 SBIR Program Solicitation. The basic document consists of edited, non-proprietary abstracts of the winning proposals submitted by small businesses. The abstracts are presented under the 15 technical topics within which Phase 1 proposals were solicited. Each project was assigned a sequential identifying number from 001 to 301, in order of its appearance in the body of the report. Appendixes to provide additional information about the SBIR program and permit cross-reference of the 1991 Phase 1 projects by company name, location by state, principal investigator, NASA Field Center responsible for management of each project, and NASA contract number are included
Investigation of a piezo-polymer array transducer for pulse-echo ultrasonic material examinations
The aim of this investigation was to make a flexible array of
pulse-echo ultrasound transducers by etching two orthogonal linear
arrays of conducting elements into the metallisation of either side of
a sheet of PVdF. These would then be multiplexed under computer
control in an X-Y raster, thereby forming an image of subsurface
defects in a material specimen.
A potential source model was used to predict the sensitivity
of a single element air-backed transducer far from resonance. Initial
investigations confirmed the predictions, and reaffirmed the results
of previous workers.
In making a prototype array, it was found necessary to use a
bi-laminar arrangement with a central ground plane, due to
difficulties with crosstalk and charge leakage into the specimen
materials. The radiation pattern of this array was tested and found
to agree with the predictions for Fraunhofer (Far-Field) radiation.
A 10 MHz analogue to digital converter was constructed to
interface with the IBM-PC clone as a transient recorder, through a
data capture program written in 'C'. However, the electrical noise
generated by the PC was found to interfere strongly with the signal
from the array transducer.
A wide-band amplifier and full-wave rectifier was then added
to the multiplexer and A/D converter, and the system enclosed in an
electrically isolated environment, which made it possible to obtain
clear signal data from the transducer.
Non-linear regression was implemented in the software, to
smooth the data and locate echo peaks, and the most frequently
occurring peak separation was used to indicate sample thickness at
that location in a false-colour mapping on the screen of the PC
Abordagem baseada em ISHM para detecção de falha em uma máquina rotativa com eixo de material compósito
FAPEMIG - Fundação de Amparo a Pesquisa do Estado de Minas GeraisTrabalho de Conclusão de Curso (Graduação)Composite shafts have been showing promising results when applied to rotating machines due to its low weight/strength ratio and good fatigue resistance. Despite the advantages in comparison to more traditional materials, composites present different types of damage that are difficult to detect. Therefore, it is necessary to use monitoring techniques to detect incipient damages and prevent failure. So, this work evaluates the structural health monitoring method based on electromechanical impedance (ISHM) applied in a rotating machine with a composite shaft. This methodology uses the piezoelectric transducers bonded to the host structure as sensor and actuator to detect damage by monitoring changes in its electric impedance. Usually, the evaluation of the impedance responses is performed by applying damage metrics, which allows the quantification of the influence of damage. This is possible since the sensor’s electrical impedance is directly related to the mechanical impedance of the structure. For this investigation, two sensors (each one with four piezoelectric patches connected in parallel) were attached to the composite shaft. To simulate the damage condition, a nut was attached in different positions on the shaft. Also, in order to increase the robustness of the ISHM technique, the effects of the rotation speed of the rotor and temperature variation were evaluated. Additionally, a data normalization based on a hybrid optimization method associated with a given damage metric is used to minimize these influences
Index to NASA Tech Briefs, 1972
Abstracts of 1972 NASA Tech Briefs are presented. Four indexes are included: subject, personal author, originating center, and Tech Brief number
NASA SBIR abstracts of 1992, phase 1 projects
The objectives of 346 projects placed under contract by the Small Business Innovation Research (SBIR) program of the National Aeronautics and Space Administration (NASA) are described. These projects were selected competitively from among proposals submitted to NASA in response to the 1992 SBIR Program Solicitation. The basic document consists of edited, non-proprietary abstracts of the winning proposals submitted by small businesses. The abstracts are presented under the 15 technical topics within which Phase 1 proposals were solicited. Each project was assigned a sequential identifying number from 001 to 346, in order of its appearance in the body of the report. Appendixes to provide additional information about the SBIR program and permit cross-reference of the 1992 Phase 1 projects by company name, location by state, principal investigator, NASA Field Center responsible for management of each project, and NASA contract number are included
Nonlinear mechanisms in passive microwave devices
Premi extraordinari doctorat curs 2010-2011, à mbit d’Enginyeria de les TICThe telecommunications industry follows a tendency towards smaller devices, higher power and higher frequency, which imply an increase on the complexity of the electronics involved. Moreover, there is a need for extended capabilities like frequency tunable devices, ultra-low losses or high power handling, which make use of advanced materials for these purposes. In addition, increasingly demanding communication standards and regulations push the limits of the acceptable performance degrading indicators. This is the case of nonlinearities, whose effects, like increased Adjacent Channel Power Ratio (ACPR), harmonics, or intermodulation distortion among others, are being included in the performance requirements, as maximum tolerable levels.
In this context, proper modeling of the devices at the design stage is of crucial importance in predicting not only the device performance but also the global system indicators and to make sure that the requirements are fulfilled. In accordance with that, this work proposes the necessary steps for circuit models implementation of different passive microwave devices, from the linear and nonlinear measurements to the simulations to validate them. Bulk acoustic wave resonators and transmission lines made of high temperature superconductors, ferroelectrics or regular metals and dielectrics are the subject of this work. Both phenomenological and physical approaches are considered and circuit models are proposed and compared with measurements. The nonlinear observables, being harmonics, intermodulation distortion, and saturation or detuning, are properly related to the material properties that originate them. The obtained models can be used in circuit simulators to predict the performance of these microwave devices under complex modulated signals, or even be used to predict their performance when integrated into more complex systems. A key step to achieve this goal is an accurate characterization of materials and devices, which is faced by making use of advanced measurement techniques. Therefore, considerations on special measurement setups are being made along this thesis.Award-winningPostprint (published version
MEMS Technology for Biomedical Imaging Applications
Biomedical imaging is the key technique and process to create informative images of the human body or other organic structures for clinical purposes or medical science. Micro-electro-mechanical systems (MEMS) technology has demonstrated enormous potential in biomedical imaging applications due to its outstanding advantages of, for instance, miniaturization, high speed, higher resolution, and convenience of batch fabrication. There are many advancements and breakthroughs developing in the academic community, and there are a few challenges raised accordingly upon the designs, structures, fabrication, integration, and applications of MEMS for all kinds of biomedical imaging. This Special Issue aims to collate and showcase research papers, short commutations, perspectives, and insightful review articles from esteemed colleagues that demonstrate: (1) original works on the topic of MEMS components or devices based on various kinds of mechanisms for biomedical imaging; and (2) new developments and potentials of applying MEMS technology of any kind in biomedical imaging. The objective of this special session is to provide insightful information regarding the technological advancements for the researchers in the community
Recommended from our members
The Convergence of Parametric Resonance and Vibration Energy Harvesting
Energy harvesting is an emerging technology that derives electricity from the ambient environment in a decentralised and self-contained fashion. Applications include self-powered medical implants, wearable electronics and wireless sensors for structural health monitoring. Amongst the vast options of ambient sources, vibration energy harvesting (VEH) has attracted by far the most
research attention. Two of the key persisting issues of VEH are the limited power density compared to conventional power supplies and confined operational frequency bandwidth in light of the random, broadband and fast-varying nature of real vibration.
The convention has relied on directly excited resonance to maximise the mechanical-to-electrical energy conversion efficiency. This thesis takes a fundamentally different approach by employing parametric resonance, which, unlike the former, its resonant amplitude growth does not saturate due to linear damping. Therefore, parametric resonance, when activated, has the potential to accumulate much more energy than direct resonance. The vibrational nonlinearities that are almost always associated with parametric resonance can offer a modest frequency widening.
Despite its promising theoretical potentials, there is an intrinsic damping dependent initiation threshold amplitude, which must be attained prior to its onset. The relatively low amplitude of real vibration and the unavoidable presence of electrical damping to extract the energy render the onset of parametric resonance practically elusive. Design approaches have been devised to passively
minimise this initiation threshold.
Simulation and experimental results of various design iterations have demonstrated favourable results for parametric resonance as well as the various threshold-reduction mechanisms. For instance, one of the macro-scale electromagnetic prototypes (∼1800 cm3) when parametrically driven, has demonstrated around 50% increase in half power band and an order of magnitude higher peak power (171.5 mW at 0.57 ms−2) in contrast to the same prototype directly driven at fundamental resonance (27.75 mW at 0.65 ms−2). A MEMS (micro-electromechanical system) prototype with the additional threshold-reduction design needed 1 ms−2 excitation to activate parametric resonance while a comparable device without the threshold-reduction mechanism required in excess of 30 ms−2. One of the macro-scale piezoelectric prototypes operated into auto-parametric resonance has demon-strated notable further reduction to the initiation threshold. A vacuum packaged MEMS prototype demonstrated broadening of the frequency bandwidth along with higher power peak (324 nW and 160 Hz) for the parametric regime compared to when operated in room pressure (166 nW and 80 Hz), unlike the higher but narrower direct resonant peak (60.9 nW and 11 Hz in vacuum and 20.8
nW and 40 Hz in room pressure).
The simultaneous incorporation of direct resonance and bi-stability have been investigated to realise multi-regime VEH. The potential to integrate parametric resonance in the electrical domains have also been numerically explored. The ultimate aim is not to replace direct resonance but rather for the various resonant phenomena to complement each other and together harness a larger region of the available power spectrum
- …