53 research outputs found

    Endorobots for Colonoscopy:Design Challenges and Available Technologies

    Get PDF
    Colorectal cancer (CRC) is the second most common cause of cancer death worldwide, after lung cancer (Sung et al., 2021). Early stage detection is key to increase the survival rate. Colonoscopy remains to be the gold standard procedure due to its dual capability to optically inspect the entire colonic mucosa and to perform interventional procedures at the same time. However, this causes pain and discomfort, whereby it requires sedation or anaesthesia of the patient. It is a difficult procedure to perform that can cause damage to the colonic wall in some cases. Development of new technologies aims to overcome the current limitations on colonoscopy by using advancements in endorobotics research. The design of these advanced medical devices is challenging because of the limited space of the lumen, the contorted shape, and the long tract of the large bowel. The force applied to the colonic wall needs to be controlled to avoid collateral effects such as injuries to the colonic mucosa and pain during the procedure. This article discusses the current challenges in the colonoscopy procedure, the available locomotion technologies for endorobots used in colonoscopy at a prototype level and the commercial products available

    Modeling, Analysis, Force Sensing and Control of Continuum Robots for Minimally Invasive Surgery

    Get PDF
    This dissertation describes design, modeling and application of continuum robotics for surgical applications, specifically parallel continuum robots (PCRs) and concentric tube manipulators (CTMs). The introduction of robotics into surgical applications has allowed for a greater degree of precision, less invasive access to more remote surgical sites, and user-intuitive interfaces with enhanced vision systems. The most recent developments have been in the space of continuum robots, whose exible structure create an inherent safety factor when in contact with fragile tissues. The design challenges that exist involve balancing size and strength of the manipulators, controlling the manipulators over long transmission pathways, and incorporating force sensing and feedback from the manipulators to the user. Contributions presented in this work include: (1) prototyping, design, force sensing, and force control investigations of PCRs, and (2) prototyping of a concentric tube manipulator for use in a standard colonoscope. A general kinetostatic model is presented for PCRs along with identification of multiple physical constraints encountered in design and construction. Design considerations and manipulator capabilities are examined in the form of matrix metrics and ellipsoid representations. Finally, force sensing and control are explored and experimental results are provided showing the accuracy of force estimates based on actuation force measurements and control capabilities. An overview of the design requirements, manipulator construction, analysis and experimental results are provided for a CTM used as a tool manipulator in a traditional colonoscope. Currently, tools used in colonoscopic procedures are straight and exit the front of the scope with 1 DOF of operation (jaws of a grasper, tightening of a loop, etc.). This research shows that with a CTM deployed, the dexterity of these tools can be increased dramatically, increasing accuracy of tool operation, ease of use and safety of the overall procedure. The prototype investigated in this work allows for multiple tools to be used during a single procedure. Experimental results show the feasibility and advantages of the newly-designed manipulators

    A Biomimetic steering robot for Minimally invasive surgery application

    Get PDF
    International audienceMinimally Invasive Surgery represents the future of many types of medical inter- ventions such as keyhole neurosurgey or transluminal endoscopic surgery. These procedures involve insertion of surgical instruments such as needles and endoscopes into human body through small incision/ body cavity for biopsy and drug delivery. However, nearly all surgical instruments for these procedures are inserted manually and there is a long learning curve for surgeons to use them properly. Many research efforts have been made to design active instruments (endoscope, needles) to improve this procedure during last decades. New robot mechanisms have been designed and used to improve the dexterity of current endoscope. Usually these robots are flexible and can pass the constrained space for fine manipulations. In recent years, a con- tinuum robotic mechanism has been investigated and designed for medical surgery. Those robots are characterized by the fact that their mechanical components do not have rigid links and discrete joints in contrast with traditional robot manipula- tors. The design of these robots is inspired by movements of natural animals such as tongues, elephant trunks and tentacles. The unusual compliance and redundant degrees of freedom of these robots provide strong potential to achieve delicate tasks successfully even in cluttered and unstructured environments. This chapter will present a complete application of a continuum robot for Mini- mally Invasive Surgery of colonoscopy. This system is composed of a micro-robotic tip, a set of position sensors and a real-time control system for guiding the explo- ration of colon. Details will be described on the modeling of the used pneumatic actuators, the design of the mechanical component, the kinematic model analysis and the control strategy for automatically guiding the progression of the device inside the human colon. Experimental results will be presented to check the perfor- mances of the whole system within a transparent tube

    The endoscopy evolution: 'the superscope era'

    Get PDF
    Developments to the design of the flexible endoscope are transforming the field of gastroenterology. There is a drive to improve colonic adenoma detection rates leading to advancements in the design of the colonoscope. Novel endoscopes now allow increased visualisation of colonic mucosa, including behind colonic folds, and aim to reduce pain associated with the procedure. In addition, a shift in surgical paradigm towards minimally invasive endoluminal surgery has meant innovations in flexible platforms are being sought. There are a number of limitations of the basic endoscope. These include a lack of stability and triangulation of instruments. Modifications to the flexible endoscope design form the basis of a number of newly developed and research platforms, some of which are discussed in this review

    Space-Capable Long and Thin Continuum Robotic Cable

    Get PDF
    Design of continuum robots, i.e. robots with continuous backbones, has been an active area of research in robotics for minimally invasive surgery, search and rescue, object manipulation, etc. Along the same lines, NASA developed Tendril , the first long and thin continuum robot of its kind, intended for in-space inspection applications. The thesis starts with describing and discussing the key disadvantages of the current state of the art mechanical design of Tendril\u27\u27 producing undesirable effects during operation. It then includes the design specifics of a novel concept for construction of a next generation long and thin, space-cable, multi-section, continuum cable-like robot, with a modified mechanical design for better performance. The new design possesses key features including controllable bending along its entire length, local compression and a compact actuation package. This new design is detailed in two versions. The first is a planar variant (suited for a 2D workspace), explaining the principle which allows the cable robot to achieve the above mentioned features. It is followed by a refined spatial version (suited for 3D workspace), where the functional characteristics are achieved within the desired aspect ratio of thin (less than 1 cm diameter) and relatively longer length (more than 100 cm) of the robotic cable. A new forward kinematic model is then developed extending the established models for constant-curvature continuum robots, to account for the new design feature of controllable compression (in the hardware) and is validated by performing experiments with the robot in (2D) planar and (3D) spatial scenarios. This new model is found to be effective as a baseline to predict the performance of such a long and thin continuum cable\u27\u27 robot

    Design of a 2 DOFs Mini Hollow Joint Actuated with SMA Wires

    Get PDF
    Shape memory alloys (SMAs) are smart materials used in robotics because of its light weight and high force-to-weight ratio. The low energy efficiency, up to 5%, has limited their use for large actuators. However, they have shown advantages in the design of mini-robots because of the limited volume required for the actuation system. The present study reports the design and construction of a mini compliant joint (MCJ) with a 2 degrees of freedom (DOFs) intersecting axis. The MCJ prototype has a 20 mm external diameter surrounding a cavity of 8 mm, weighs 2 g, is 20 mm high and can perform an angle rotation of 30 ∘ in less than 260 ms. It uses SMA NiTi wires in antagonistic configuration and springs to reduce the energy consumption and minimise heat production. The design methods and experimental results of the manufactured prototype are reported and discussed

    Robotic technology and endoluminal surgery in digestive surgery

    Get PDF
    BACKGROUND. Colorectal cancer (CRC) is the third most common cancer in males and second in females, and the fourth most common cause of cancer death worldwide. The implementation of screening programs has allowed to the identification of an increasing number of early-stage neoplastic lesions. Presently, superficial colorectal neoplasms (including precancerous lesions and early cancer) can be resected in the colon by Endoscopic Mucosal Resection (EMR) and Endoscopic Submucosal Dissection (ESD), while in the rectum by Transanal Endoscopic Microsurgery (TEM). They are the preferred choices inside of the minimally invasive panorama regarding the CRC treatment. TEM technique offers more advantages than EMR and ESD, but it can’t overcome the recto-sigmoid junction. Many authors, research institutes and biomedical industries have proposed different solutions for microsurgery dissection of early lesions in the colon, but all these proposals have in common the development of platforms expressly designed for this use, with significant purchasing and management costs. The aim of our research project is to develop a robotic platform that allows to treat lesions throughout the colon limiting the costs of management and purchasing. This new robotic platform, developed in collaboration with Scuola Superiore Sant’Anna in Pisa, is called RED (Robot for Endoscopic Dissection). At the tip of a standard endoscope a hood (RED) is placed. RED is equipped by two extractable teleoperated robotic arms (i.e., diathermic hook and gripper); their motion is provided by onboard miniaturized commercial motors and a dedicated external platform. The endoscopist holds the endoscope near the lesion, while the operator drives the robotic arms through a remote control. MATERIALS AND METHODS. Several preliminary studies have been conducted in the following order. A first test was conducted for identification of force value for lifting and pulling maneuvers using a modified TEM instrument. A CAD study was conducted to determine the maximum size that the hood must have in order to overcome the critical angle represented by the splenic flexure. Several tests were conducted to determine the degrees of freedom of each robotic arm, starting with the CAD drawing to make subsequently the mock-ups of each configuration. Finally, a 3D mock-up was produced that was assembled on an endoscope to perform the in vitro test to evaluate the workspace and field of view using a pelvic trainer for TEM. RESULTS. The first test shown that the minimum force that the gripper will have to develop with the push-pull is 1.5N. The CAD study shown that the maximum dimensions the hood must have to overcome splenic flexure are: maximum diameter 28mm, maximum length 57mm. After several configurations was been tested, the final prototype features are: gripper arm with pitch sliding and open/close of the tip and diathermic hook arm with pitch, roll and sliding. There will be 6 such distributed motors: 3 external motors for the gripper arm that will operate through cables contained in a sheath adherent to colonscope and 3 embedded motors for diathermic hook arm (one integrated on the hood for the sliding degree of motion and the other two inside of the arm). The in-vitro test has been carried out to evaluate the workspace and they proved that the operating field vision is not obstructed by the hood and the working range is sufficiently wide to perform a dissection. CONCLUSION. Tests conducted up to this point have allowed us to identify the overall layout of the RED: dimensions, degrees of freedom, number and distribution of motors needed for the operation of robotic arms; moreover, it is proved that the device, once assembled, maintained the visual and operational field characteristics necessary to perform an accurate dissection. The next step will be to realize a RED steel final prototype and in-vivo tests will be carry out to replicate an endoscopic dissection into the colon

    Design of a Robotic Instrument Manipulator for Endoscopic Deployment

    Get PDF
    This thesis describes the initial design process for an application of continuum robotics to endoscopic surgical procedures, specifically dissection of the colon. We first introduce the long-term vision for a benchtop dual-instrument endoscopic system with intuitive haptic controllers and then narrow our focus to the design and testing of the instrument manipulator itself, which must be actuated through the long, winding channel of a standard colonoscope. Based on design requirements for a target procedure, we analyze simulations of two types of continuum robots using recently established kinematic and mechanic modeling approaches: the concentric-tube robot (CTR) and the concentric agonist-antagonist robot (CAAR). In addition, we investigate solutions to the primary engineering challenge to this system, which is accurately transmitting joint motion through exible, hollow shafts. Based on our study of the manipulator simulations and transmission shafts, we select instrument designs for prototyping and testing. We present approaches for controlling the position of the robotic instrument in real-time using an input device, and demonstrate the degree of control we can achieve in various configurations by performing time trial experiments with our prototype robotic instruments. Our observations of the manipulator during testing inform us of sources of error, and we conclude this report with suggestions for future work, including shaft design and alternative continuum manipulator approaches

    Current engineering developments for robotic systems in flexible endoscopy

    Get PDF
    The past four decades have seen an increase in the incidence of early-onset gastrointestinal cancer. Because early-stage cancer detection is vital to reduce mortality rate, mass screening colonoscopy provides the most effective prevention strategy. However, conventional endoscopy is a painful and technically challenging procedure that requires sedation and experienced endoscopists to be performed. To overcome the current limitations, technological innovation is needed in colonoscopy. In recent years, researchers worldwide have worked to enhance the diagnostic and therapeutic capabilities of endoscopes. The new frontier of endoscopic interventions is represented by robotic flexible endoscopy. Among all options, self-propelling soft endoscopes are particularly promising thanks to their dexterity and adaptability to the curvilinear gastrointestinal anatomy. For these devices to replace the standard endoscopes, integration with embedded sensors and advanced surgical navigation technologies must be investigated. In this review, the progress in robotic endoscopy was divided into the fundamental areas of design, sensing, and imaging. The article offers an overview of the most promising advancements on these three topics since 2018. Continuum endoscopes, capsule endoscopes, and add-on endoscopic devices were included, with a focus on fluid-driven, tendon-driven, and magnetic actuation. Sensing methods employed for the shape and force estimation of flexible endoscopes were classified into model- and sensor-based approaches. Finally, some key contributions in molecular imaging technologies, artificial neural networks, and software algorithms are described. Open challenges are discussed to outline a path toward clinical practice for the next generation of endoscopic devices
    • …
    corecore