58,719 research outputs found

    Design, analysis and construction of a simple pulse duplicator system

    Get PDF
    One of the most important human diseases that need to be considered in terms of development of the medical engineering devices is cardiovascular disease which is a significant cause of death globally recently. Valvular heart disease is normally treated by restoring or altering heart valves with an artificial one. But the new prosthetic valve designs necessitate testing for durability estimate and failure method. It is significant to simulate the circulation system by the building of a pulse duplicator system. This study is stated by clarifying the parameter and implementation steps of the pulse duplicator system in which the different researchers have utilized the system and tried to explain the design steps of using this system without going into the system design by steps or what are the main part of this system and how can be implemented, tested, and developed individually. In this design, a DC motor produces, through a hydraulic piston, a flow pulse to the left ventricle chamber model, which is linked with two interchangeable prosthetic heart valves. The computer is used to control and process data from volumetric flow rate and image. The findings show that the linear displacement, the velocity of the piston and the linear acceleration regularly become significant particularly and follows a sinusoidal wave shape during one cycle, when (crank length/connecting rod length) value is equal 0.2 or less. Several sets of measured flow rate readings were obtained by using flow meter sensor YF-S201, results after calibration showed the error rate falls within permissible limit

    Vital Sensory Kit For Use With Telemedicine In Developing Countries

    Get PDF
    In many developing countries, a large percentage of the population lacks access to adequate healthcare. This is especially true in India where close to 70% of the population lives in rural areas and has little to no access to hospitals or clinics. People living in rural India often times cannot afford to pay to see a doctor should they need to make the journey to a hospital. Telemedicine, a breakthrough in the past couple decades, has broken down the barrier between the patient and the physician. It has slowly been implemented in India to make doctors more available to patients through the use of video conferences and other forms of communication. A compact and affordable kit has been developed that will be used to take a patient’s blood pressure, heart rate, blood glucose concentration and oxygen saturation. Our most novel contribution is the non-invasive glucose sensor that will use a near-infrared LED and photodiode in the patient’s earlobe. Currently millions of diabetics do this by pricking their finger. By wirelessly sending data results from the vital sign kit, the first essential part of a treatment can be carried out via wireless communication, saving the doctor and patient time and money

    The effects of a video intervention on posthospitalization pulmonary rehabilitation uptake

    Get PDF
    Rationale: Pulmonary rehabilitation (PR) after hospitalizations for exacerbations of chronic obstructive pulmonary disease (COPD) improves exercise capacity and health-related quality of life and reduces readmissions. However, posthospitalization PR uptake is low. To date, no trials of interventions to increase uptake have been conducted.Objectives: To study the effect of a codesigned education video as an adjunct to usual care on posthospitalization PR uptake.Methods: The present study was an assessor- and statistician-blinded randomized controlled trial with nested, qualitative interviews of participants in the intervention group. Participants hospitalized with COPD exacerbations were assigned 1:1 to receive either usual care (COPD discharge bundle including PR information leaflet) or usual care plus the codesigned education video delivered via a handheld tablet device at discharge. Randomization used minimization to balance age, sex, FEV1 % predicted, frailty, transport availability, and previous PR experience.Measurements and Main Results: The primary outcome was PR uptake within 28 days of hospital discharge. A total of 200 patients were recruited, and 196 were randomized (51% female, median FEV1% predicted, 36 [interquartile range, 27-48]). PR uptake was 41% and 34% in the usual care and intervention groups, respectively (P = 0.37), with no differences in secondary (PR referral and completion) or safety (readmissions and death) endpoints. A total of 6 of the 15 participants interviewed could not recall receiving the video.Conclusions: A codesigned education video delivered at hospital discharge did not improve posthospitalization PR uptake, referral, or completion

    The Nuclear Spectroscopic Telescope Array (NuSTAR)

    Get PDF
    The Nuclear Spectroscopic Telescope Array (NuSTAR) is a NASA Small Explorer mission that will carry the first focusing hard X-ray (5 -- 80 keV) telescope to orbit. NuSTAR will offer a factor 50 -- 100 sensitivity improvement compared to previous collimated or coded mask imagers that have operated in this energy band. In addition, NuSTAR provides sub-arcminute imaging with good spectral resolution over a 12-arcminute field of view. After launch, NuSTAR will carry out a two-year primary science mission that focuses on four key programs: studying the evolution of massive black holes through surveys carried out in fields with excellent multiwavelength coverage, understanding the population of compact objects and the nature of the massive black hole in the center of the Milky Way, constraining explosion dynamics and nucleosynthesis in supernovae, and probing the nature of particle acceleration in relativistic jets in active galactic nuclei. A number of additional observations will be included in the primary mission, and a guest observer program will be proposed for an extended mission to expand the range of scientific targets. The payload consists of two co-aligned depth-graded multilayer coated grazing incidence optics focused onto solid state CdZnTe pixel detectors. To be launched in early 2012 on a Pegasus rocket into a low-inclination Earth orbit. Data will be publicly available at GSFC's High Energy Astrophysics Science Archive Research Center (HEASARC) following validation at the science operations center located at Caltech.Comment: 9 pages, 5 figures, to appear in Proceedings of the SPIE, Space Telescopes and Instrumentation 2010: Ultraviolet to Gamma Ra

    Development of an Oxygen Saturation Monitoring System by Embedded Electronics

    Get PDF
    Measuring Oxygenation of blood (SaO2) plays a vital role in patient’s health monitoring. This is often measured by pulse oximeter, which is standard measure during anesthesia, asthma, operative and post-operative recoveries. Despite all, monitoring Oxygen level is necessary for infants with respiratory problems, old people, and pregnant women and in other critical situations. This paper discusses the process of calculating the level of oxygen in blood and heart-rate detection using a non-invasive photo plethysmography also called as pulsoximeter using the MSP430FG437 microcontroller (MCU). The probe uses infrared lights to measure and should be in physical contact with any peripheral points in our body. The percentage of oxygen in the body is worked by measuring the intensity from each frequency of light after it transmits through the body and then calculating the ratio between these two intensities

    Southwest Research Institute assistance to NASA in biomedical areas of the technology utilization program

    Get PDF
    The activities are reported of the NASA Biomedical Applications Team at Southwest Research Institute between 25 August, 1972 and 15 November, 1973. The program background and methodology are discussed along with the technology applications, and biomedical community impacts
    • …
    corecore