587 research outputs found

    A scalable system for microcalcification cluster automated detection in a distributed mammographic database

    Get PDF
    A computer-aided detection (CADe) system for microcalcification cluster identification in mammograms has been developed in the framework of the EU-founded MammoGrid project. The CADe software is mainly based on wavelet transforms and artificial neural networks. It is able to identify microcalcifications in different datasets of mammograms (i.e. acquired with different machines and settings, digitized with different pitch and bit depth or direct digital ones). The CADe can be remotely run from GRID-connected acquisition and annotation stations, supporting clinicians from geographically distant locations in the interpretation of mammographic data. We report and discuss the system performances on different datasets of mammograms and the status of the GRID-enabled CADe analysis.Comment: 6 pages, 4 figures; Proceedings of the IEEE NNS and MIC Conference, October 23-29, 2005, Puerto Ric

    A scalable Computer-Aided Detection system for microcalcification cluster identification in a pan-European distributed database of mammograms

    Full text link
    A computer-aided detection (CADe) system for microcalcification cluster identification in mammograms has been developed in the framework of the EU-founded MammoGrid project. The CADe software is mainly based on wavelet transforms and artificial neural networks. It is able to identify microcalcifications in different kinds of mammograms (i.e. acquired with different machines and settings, digitized with different pitch and bit depth or direct digital ones). The CADe can be remotely run from GRID-connected acquisition and annotation stations, supporting clinicians from geographically distant locations in the interpretation of mammographic data. We report the FROC analyses of the CADe system performances on three different dataset of mammograms, i.e. images of the CALMA INFN-founded database collected in the Italian National screening program, the MIAS database and the so-far collected MammoGrid images. The sensitivity values of 88% at a rate of 2.15 false positive findings per image (FP/im), 88% with 2.18 FP/im and 87% with 5.7 FP/im have been obtained on the CALMA, MIAS and MammoGrid database respectively.Comment: 6 pages, 5 figures; Proceedings of the ITBS 2005, 3rd International Conference on Imaging Technologies in Biomedical Sciences, 25-28 September 2005, Milos Island, Greec

    Texture descriptors applied to digital mammography

    Get PDF
    Breast cancer is the second cause of death among women cancers. Computer Aided Detection has been demon- strated an useful tool for early diagnosis, a crucial as- pect for a high survival rate. In this context, several re- search works have incorporated texture features in mam- mographic image segmentation and description such as Gray-Level co-occurrence matrices, Local Binary Pat- terns, and many others. This paper presents an approach for breast density classi¯cation based on segmentation and texture feature extraction techniques in order to clas- sify digital mammograms according to their internal tis- sue. The aim of this work is to compare di®erent texture descriptors on the same framework (same algorithms for segmentation and classi¯cation, as well as same images). Extensive results prove the feasibility of the proposed ap- proach.Postprint (published version

    Radiographers supporting radiologists in the interpretation of screening mammography: a viable strategy to meet the shortage in the number of radiologists.

    Get PDF
    BackgroundAn alternative approach to the traditional model of radiologists interpreting screening mammography is necessary due to the shortage of radiologists to interpret screening mammograms in many countries.MethodsWe evaluated the performance of 15 Mexican radiographers, also known as radiologic technologists, in the interpretation of screening mammography after a 6 months training period in a screening setting. Fifteen radiographers received 6 months standardized training with radiologists in the interpretation of screening mammography using the Breast Imaging Reporting and Data System (BI-RADS) system. A challenging test set of 110 cases developed by the Breast Cancer Surveillance Consortium was used to evaluate their performance. We estimated sensitivity, specificity, false positive rates, likelihood ratio of a positive test (LR+) and the area under the subject-specific Receiver Operating Characteristic (ROC) curve (AUC) for diagnostic accuracy. A mathematical model simulating the consequences in costs and performance of two hypothetical scenarios compared to the status quo in which a radiologist reads all screening mammograms was also performed.ResultsRadiographer's sensitivity was comparable to the sensitivity scores achieved by U.S. radiologists who took the test but their false-positive rate was higher. Median sensitivity was 73.3 % (Interquartile range, IQR: 46.7-86.7 %) and the median false positive rate was 49.5 % (IQR: 34.7-57.9 %). The median LR+ was 1.4 (IQR: 1.3-1.7 %) and the median AUC was 0.6 (IQR: 0.6-0.7). A scenario in which a radiographer reads all mammograms first, and a radiologist reads only those that were difficult for the radiographer, was more cost-effective than a scenario in which either the radiographer or radiologist reads all mammograms.ConclusionsGiven the comparable sensitivity achieved by Mexican radiographers and U.S. radiologists on a test set, screening mammography interpretation by radiographers appears to be a possible adjunct to radiologists in countries with shortages of radiologists. Further studies are required to assess the effectiveness of different training programs in order to obtain acceptable screening accuracy, as well as the best approaches for the use of non-physician readers to interpret screening mammography

    Automated pectoral muscle identification on MLOâ view mammograms: Comparison of deep neural network to conventional computer vision

    Full text link
    Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/149204/1/mp13451_am.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/149204/2/mp13451.pd

    Spatially varying threshold models for the automated segmentation of radiodense tissue in digitized mammograms

    Get PDF
    The percentage of radiodense (bright) tissue in a mammogram has been correlated to an increased risk of breast cancer. This thesis presents an automated method to quantify the amount of radiodense tissue found in a digitized mammogram. The algorithm employs a radial basis function neural network in order to segment the breast tissue region from the remainder of the X-ray. A spatially varying Neyman-Pearson threshold is used to calculate the percentage of radiodense tissue and compensate for the effects of tissue compression that occurs during a mammography procedure. Results demonstrating the efficacy of the technique are demonstrated by exercising the algorithm on two separate sets of mammograms - one obtained from Brigham Women\u27s Hospital, Harvard Medical School and the other set obtained from Fox Chase Cancer Center and digitized at Rowan University. The results of the algorithm compare favorably with a previously established manual segmentation technique