1,104 research outputs found
Removal of power-line interference from the ECG: a review of the subtraction procedure
BACKGROUND: Modern biomedical amplifiers have a very high common mode rejection ratio. Nevertheless, recordings are often contaminated by residual power-line interference. Traditional analogue and digital filters are known to suppress ECG components near to the power-line frequency. Different types of digital notch filters are widely used despite their inherent contradiction: tolerable signal distortion needs a narrow frequency band, which leads to ineffective filtering in cases of larger frequency deviation of the interference. Adaptive filtering introduces unacceptable transient response time, especially after steep and large QRS complexes. Other available techniques such as Fourier transform do not work in real time. The subtraction procedure is found to cope better with this problem. METHOD: The subtraction procedure was developed some two decades ago, and almost totally eliminates power-line interference from the ECG signal. This procedure does not affect the signal frequency components around the interfering frequency. Digital filtering is applied on linear segments of the signal to remove the interference components. These interference components are stored and further subtracted from the signal wherever non-linear segments are encountered. RESULTS: Modifications of the subtraction procedure have been used in thousands of ECG instruments and computer-aided systems. Other work has extended this procedure to almost all possible cases of sampling rate and interference frequency variation. Improved structure of the on-line procedure has worked successfully regardless of the multiplicity between the sampling rate and the interference frequency. Such flexibility is due to the use of specific filter modules. CONCLUSION: The subtraction procedure has largely proved advantageous over other methods for power-line interference cancellation in ECG signals
Performance Evaluation of Wavelet De-Noising Schemes for Suppression of Power Line Noise in Electrocardiogram Signals
Power line noise introduces distortions to recorded electrocardiogram (ECG) signals. These distortions compromise the integrity and negatively affect the interpretation of the ECG signals. Despite the fact that the amplifiers used in biomedical signal processing have high common mode rejection ratio (CMRR), ECG recordings are still often corrupted with residual Power Line Interference (PLI) noise. Further improvement in the hardware solutions do not have significant achievements in PLI noise suppression but rather introduce other adverse effects. Software approach is necessary to refine ECG data. Evaluation of PLI noise suppression in ECG signal in the wavelet domain is presented. The performance of the Hard Threshold Shrinkage Function (HTSF), the Soft Threshold Shrinkage Function (STSF), the Hyperbola Threshold Shrinkage Function (HYTSF), the Garrote Threshold Shrinkage Function (GTSF), and the Modified Garrote Threshold Shrinkage Function (MGTSF) for the suppression of PLI noise are evaluated and compared with the aid of an algorithm. The optimum tuning constant for the Modified Garrote Threshold Shrinkage Function (MGTSF) is found to be 1.18 for PLI noise. GTSF is found to have best performance closely followed by MGTSF in term of filtering Gain. HTSF recorded the lowest Gain. Filtering against PLI noise in the wavelet domain preserves the key features of the signal such as the QRS complex
A novel wavelet-based filtering strategy to remove powerline interference from electrocardiograms with atrial fibrillation
This is an author-created, un-copyedited versÃon of an article published in Physiological Measurement. IOP Publishing Ltd is not responsÃble for any errors or omissÃons in this versÃon of the manuscript or any versÃon derived from it. The VersÃon of Record is available online at http://doi.org/10.1088/1361-6579/aae8b1[EN] Objective: The electrocardiogram (ECG) is currently the most widely used recording to diagnose cardiac disorders, including the most common supraventricular arrhythmia, such as atrial fibrillation (AF). However, different types of electrical disturbances, in which power-line interference (PLI) is a major problem, can mask and distort the original ECG morphology. This is a significant issue in the context of AF, because accurate characterization of fibrillatory waves (f-waves) is unavoidably required to improve current knowledge about its mechanisms. This work introduces a new algorithm able to reduce high levels of PLI and preserve, simultaneously, the original ECG morphology. Approach: The method is based on stationary wavelet transform shrinking and makes use of a new thresholding function designed to work successfully in a wide variety of scenarios. In fact, it has been validated in a general context with 48 ECG recordings obtained from pathological and non-pathological conditions, as well as in the particular context of AF, where 380 synthesized and 20 long-term real ECG recordings were analyzed. Main results: In both situations, the algorithm has reported a notably better performance than common methods designed for the same purpose. Moreover, its effectiveness has proven to be optimal for dealing with ECG recordings affected by AF, sincef-waves remained almost intact after removing very high levels of noise. Significance: The proposed algorithm may facilitate a reliable characterization of thef-waves, preventing them from not being masked by the PLI nor distorted by an unsuitable filtering applied to ECG recordings with AF.Research supported by grants DPI2017-83952-C3 MINECO/AEI/FEDER, UE and SBPLY/17/180501/000411 from Junta de Comunidades de Castilla-La Mancha.GarcÃa, M.; MartÃnez, M.; Ródenas, J.; Rieta, JJ.; Alcaraz, R. (2018). A novel wavelet-based filtering strategy to remove powerline interference from electrocardiograms with atrial fibrillation. Physiological Measurement. 39(11):1-15. https://doi.org/10.1088/1361-6579/aae8b1S115391
Semiparametric curve alignment and shift density estimation for biological data
Assume that we observe a large number of curves, all of them with identical,
although unknown, shape, but with a different random shift. The objective is to
estimate the individual time shifts and their distribution. Such an objective
appears in several biological applications like neuroscience or ECG signal
processing, in which the estimation of the distribution of the elapsed time
between repetitive pulses with a possibly low signal-noise ratio, and without a
knowledge of the pulse shape is of interest. We suggest an M-estimator leading
to a three-stage algorithm: we split our data set in blocks, on which the
estimation of the shifts is done by minimizing a cost criterion based on a
functional of the periodogram; the estimated shifts are then plugged into a
standard density estimator. We show that under mild regularity assumptions the
density estimate converges weakly to the true shift distribution. The theory is
applied both to simulations and to alignment of real ECG signals. The estimator
of the shift distribution performs well, even in the case of low
signal-to-noise ratio, and is shown to outperform the standard methods for
curve alignment.Comment: 30 pages ; v5 : minor changes and correction in the proof of
Proposition 3.
Surface electromyography low-frequency content: Assessment in isometric conditions after electrocardiogram cancellation by the Segmented-Beat Modulation Method
Background: Surface electromyography (SEMG) is widely used in clinics for assessing muscle functionality. All procedures proposed for noise reduction alter SEMG spectrum, especially in the low-frequency band (below 30 Hz). Indeed, low-frequency band is generally addressed to motion artifacts and electrocardiogram (ECG) interference without any further investigation on the possibility of SEMG having significant spectral content. The aim of the present study was evaluating SEMG frequency content to understand if low-frequency spectral content is negligible or, on the contrary, represents a significant SEMG portion potentially providing relevant clinical information. Method: Isometric recordings of five muscles (sternocleidomastoideus, erectores spinae at L4, rectus abdominis, rectus femoris and tibialis anterior) were acquired in 10 young healthy voluntary subjects. These recordings were not affected by motion artifacts by construction and were pre-processed by the Segmented-Beat Modulation Method for ECG deletion before performing spectral analysis. Results: Results indicated that SEMG frequency content is muscle and subject dependent. Overall, the 50th[25th;75th] percentiles spectrum median frequency and spectral power below 30 Hz were 74[54; 87] Hz and 18[10; 31] % of total (0–450 Hz) spectral power. Conclusions: Low-frequency spectral content represents a significant SEMG portion and should not be neglected. Keywords: Surface electromyographic signal, Electromyographic spectrum, Segmented-Beat Modulation Method, Non-linear filtering, Spectral analysi
Comparative power spectral analysis of simultaneous elecroencephalographic and magnetoencephalographic recordings in humans suggests non-resistive extracellular media
The resistive or non-resistive nature of the extracellular space in the brain
is still debated, and is an important issue for correctly modeling
extracellular potentials. Here, we first show theoretically that if the medium
is resistive, the frequency scaling should be the same for electroencephalogram
(EEG) and magnetoencephalogram (MEG) signals at low frequencies (<10 Hz). To
test this prediction, we analyzed the spectrum of simultaneous EEG and MEG
measurements in four human subjects. The frequency scaling of EEG displays
coherent variations across the brain, in general between 1/f and 1/f^2, and
tends to be smaller in parietal/temporal regions. In a given region, although
the variability of the frequency scaling exponent was higher for MEG compared
to EEG, both signals consistently scale with a different exponent. In some
cases, the scaling was similar, but only when the signal-to-noise ratio of the
MEG was low. Several methods of noise correction for environmental and
instrumental noise were tested, and they all increased the difference between
EEG and MEG scaling. In conclusion, there is a significant difference in
frequency scaling between EEG and MEG, which can be explained if the
extracellular medium (including other layers such as dura matter and skull) is
globally non-resistive.Comment: Submitted to Journal of Computational Neuroscienc
- …